Please keep this sheet for review before use of unit.
Please observe the following:
Serious injury may occur if instructions are not followed
Product failure or injury can occur if instructions are not followed
Do not connect touch the terminals when power is on.
RISK OF ELECTRIC SHOCK!
1. This is not a safety product and is not to be used with machinery
that requires use of safety control.
2. Do not disassemble or modify this unit. It may lead to electric
shock/ re.
1. This unit shall not be used outdoors or in places with high sunlight,
humidity or other harsh conditions.
2. Do not use the unit in places where there is ammable or explosive
gas.
3. Do not use this unit beyond rated power.
4. Please check the unit for wrong wiring before power on.
5. Do not use this unit in places where there is vibration or impact.
6. Do not use water or oil based detergent for cleaning the unit.
7. Do not use unit in places with high EM noise as it may lead to
product malfunction.
8. Do not use excessive force to tighten the unit and do not hammer
the unit.
9. Please process it as industrial waste and dispose responsibily.
SPECIFICATIONS
Represented by:
Intech Systems Chennai Pvt. Ltd.
S-2, Guindy Industrial Estate
Chennai - 32. Ph: 044 4353 8888
www.inno.sg
DWA
ADVANCE
WEIGHING METER
INSTRUCTION SHEET
Thank you for selecting INNO for your requirement.
This sheet describes the procedure and precautions
required for installing and operating the product.
Kindly read this sheet before operating or installing
the product. Store the sheet for future reference.
Cat. No. DWA-419
Compensate for the same by provide a cooling fan.
3. Install the product horizontally.
4. Mount to a panel with 1~8mm thickness only.
product seperately from the power lines.
6. Allow the product to operate without load for atleast 15 minutes.
7. Do not connect anything to the unused terminals.
that the operator can quickly turn OFF power.
9. Use only specied size of tinned crimp terminals of size
M3, width: 4mm max.
wire is to be betweed 2-4mm.
*For details on Customized/ Special Models contact Seller
NOTE:
Operating instructions are available seperately in the Operation Manual.
Download the OPERATION MANUAL at “www.inno.sg/dwa_manual”
24 VDC ± 10%; 5W Power Consumpon
5 VDC 120mA for 8*350ΩLoadcells
4 wire Loadcell; 0-19.5mV
2 Relay (24VDC/250VAC, 1A SPDT)
5 digit, 7 Segment RED LED; 3 Red LED Indicaon for Alarm Low, High, Net
Internal Resoluon 1/1,000,000
CMC GB/T 7724-2008; OMIL R76:2006; Accuracy Grade III
Operaon: -25° ~ 40°C; Storage: -30° ~ 60°C (non- freezing; non- condensing)
Operaon: 25 ~ 85% RH; Storage: 25 ~ 90% RH (non- condensing)
IP 65 Front Panel: ABS; Housing: Aluminium
CONNECTION DIAGRAM
AO COM2 AL AH
AO+ AO- B- A+
SIG+ SIG- EXC- EXC+ TXD RXD GND DC- DC+
LOADCELL COM1 POWERPG
mV
V
mA