Innovation VIEWLIGHT DLR-700 User manual


CONTENT
1 Product introduction........................................................................................................................1
2 Safe Notice......................................................................................................................................2
2.1 Notice in operation..................................................................................................................2
2.2 Notice in storage .....................................................................................................................3
2.3 Notice in moving.....................................................................................................................3
2.4 Notice in assembling...............................................................................................................3
2.5 Notice in wires connection......................................................................................................4
2.6 Notice after operation .............................................................................................................5
2.7 Notice in maintenance.............................................................................................................5
2.8 Notice in accident ...................................................................................................................5
2.9 Marks on machine...................................................................................................................6
3 Introduction to machine ..................................................................................................................7
3.1 Main body...............................................................................................................................7
3.2 Operation panel.......................................................................................................................9
4 Operation ......................................................................................................................................13
4.1 Assembling............................................................................................................................13
4.2 Test...................................................................................................................................13
4.3 Operation ..............................................................................................................................14
4.3.1 Lens settings.............................................................................................................14
4.3.2 Lens measurement...................................................................................................15
5 Maintenance..................................................................................................................................26
5.1 daily care............................................................................................................................26
5.2 replacement of materials ....................................................................................................27
5.3 machine clean........................................................................................................................27
5.4 notice in moving ..............................................................................................................28
5.5 service information ............................................................................................................28
6 Simple fault phenomenon and solution.........................................................................................29
6.1 solution to general problem...................................................................................................29
7 Performance parameter .................................................................................................................31
8 Attached list (packing parts)...................................................................................................32

Auto lens meter operation manual
1
1 Product introduction
DLR-700 can measure the degree of single vision lens, double vision
lens, three visions lens and progressive lens (PPL)quickly and precisely.
This machine has LCD touch screen, on which can show the measured data
and PD of left and right eyes. And it also can show the centering by diagram
marks on the screen and it can help to adjust the optical center of lens
quickly. The 7-inch high-resolution TFT touch screen can show everything
smooth and fine.
There is brief menu. Just pressing the keys on the screen, the graphs
will show their functions accurately.
LM-700 is the auto lens meter which is specialized for lens measurement.
The Implementation of the enterprise standard Q31/0113000121C001-2016,
which is in the line with the national metrological verification procedures
lens meter JJG 580—2005.
The max degree of this machine:±25.00D.
The function direction of DLR-700
Model DLR-700
Sphere √
Cylinder √
Prism √
Progressive √
Color lens √
PD,PH √
Print √
Remarks With PD,PH and Print

Auto lens meter operation manual
2
2 Safe Notice
In this manual, the following marks mean the safe notice, please refer to
the follow:
Notice:there will be dangerous. If not avoid, it can cause damage.
Notice:there will be dangerous, if not avoid, it can cause damage to
the function of machine.
2.1 Notice in operation
Notice:
●Don’t open or touch the inner part of machine if not necessary, or it may cause
electric shock or make problem to machine.
●To use the stipulated voltage, if too high or too low, it will influence the
operation or even cause damage to machine or result in electric shock.
●Don’t put the wires under machine, or it will break the wires and cause
cutting-out, fire disaster or electric shock.
●
If the metal core of wires is exposed, it should be exchanged right
away,otherwise, it will cause fire disaster or electric shock.

Auto lens meter operation manual
3
2.2 Notice in storage
Notice:
2.3 搬动时应注意的事项
2.3 Notice in moving
2.4 Notice in assembling
Notice:
●Don’t put the machine at some place humid or poisonous or with corrosive
liquid or air.
●Don’t put machine under the sunshine. To keep the suitable temperature and
humidness.
●Notice: if the change of the outside temperature is too big, it will influence the
operation of machine. Then it just need to put machine under the stable
temperature for 3-10 hours, then it can be operated normally.
●Don’t pull the wires or cable, which will damage the machine or hurt people.
●Don’t take machine by seizing the LCD screen when moving machine. You
should hold the base by hands. Or it will hurt people or damage machine.
●Don’t put machine in humid place. Any water into machine will cause electric
shock or other machine problem.
●To put machine at smooth place. Any shake during operation will make
machine fall down and may hurt people or damage machine.

Auto lens meter operation manual
4
Notice:
2.5 Notice in wires connection
Notice:
●Don’t operate machine under sunshine or near filament lamp. Don’t install
machine on the place that the surface with strong light reflect, like glass show
box, mirror or polishing desk. Otherwise, these situation will influence the
operation or make error.
●Don’t operate machine at the place against electric fans or air conditioner,
otherwise the dust will be flowed into machine which will influence the
preciseness of measured data.
●Don’t operate the machine at the place with dust or humid and hot, which
will influence operation.
●Don’t put too many plugs on one power socket, which will make it too hot and
cause fire disaster.
●There must be ground connection to the power supply to protect the security of
people and machine.

Auto lens meter operation manual
5
2.6 Notice after operation
Notice:
2.7 Notice in maintenance
Notice:
2.8 Notice in accident
Notice:
●To cut off power supply when not run the machine, and put on the dust cover.
Long time connection to power supply will short the usage life of machine. And
without dust for long time, the falling dust will influence the preciseness of
machine.
●Not operate machine for long time, please pull the plug out from power socket,
in case to prevent from fire disaster.
●If there is any problem with machine and need to take down the machine for
check, please contact with our agent or our branch office. You need to take all
the responsible to any damage to machine from your personal action to it.
●Don’t scrape the protecting lens which under the lens base, otherwise it will
very influence the preciseness of measured data.
●If the LCD screen broken, to knock it into pieces and wash and sweep them
away by alcohol, then to burn them down. If hands touch the liquid crystal, then
to wash hands with water right away.

Auto lens meter operation manual
6
2.9 Marks on machine
Please read the manual carefully.
○It means that the power supply be off.
| It means that the power supply be on

Auto lens meter operation manual
7
3 Introduction to machine
3.1 Main body
Figure 3.1 Outlooking of main body
●lens fixing frame: when fixing the lens, to up the frame and down it
with gentle. When take down lens, to up the frame till there is a sound
like “ka”, then the frame will be locked.
●Sliding nose frame: which used for measuring PD. To put the nose pad
Switch
lens fixing
frame
Sliding nose
pad frame
Lens base
Lens table
Point button
Lens table knob
printer
Memory switch

Auto lens meter operation manual
8
on the frame and move the frame, the PD will be measured out
automatically.
Figure 3.2 injections on the back of machine
●Lens base: which used for putting lens and as the basic point of
measurement. Dust cover: which used for protecting machine from dust.
Before operating machine, please take down the dust cover.
●Switch :short-time press to turn on machine, and longer press to turn
off machine.
Port
Out power
injection
USB
connection
Fuse cover

Auto lens meter operation manual
9
●Point button: to mark the center of lens and the optical axis of
astigmatism glasses.
●Lens table button: to dolly moves lens and measure the diameter of lens
(the diameter can be read out by the degree scale under the button.)
●lens table: to fix the direction of lens frame. To put the bottom of
lens frame on the lens table when make the measurement. Don’t move the
lens table directly, but just moving it by lens table knob.
●Printer: to print the measured data.
Note: no operation for some time, machine will turn to screen saver mode.
The time of this mode can be set in Menu. Back to measure mode, just gentle
touching on the screen.
3.2 Operation panel
Measurement interface
L/ R
PD
PH
Drone
Time

Auto lens meter operation manual
10
Figure 3.3 measurement interface
Showed degree: 0.01、0.12、0.25D
Astigmatism mode: +、+/—、—
Drone
To show the measured point when measure lens.
The shape of drone will change as follow when focusing:
十:Off center
十:close to center( within 0.5△) and it will be showed in screen.
十:focused on center (mark point) and it will be showed on screen.
L/ R
When the left side or right side (L/ R) has been set and the mark showed
up, the degree of the side will be showed under the mark.
S means to measure one side lens.
PD
To show PD(LPD:left PD;RPD:right PD) and the PD of glasses.
Marks:functions are showed as marks
Menu: to enter into
and modify the
system parameter.
Memory: to save the
measured data
Mode: to change the
measurement
mode( sin
gle or
progressive
measurement mode)
Print: to print out
the data

Auto lens meter operation manual
11
Figure 3.4 function of marks on measurement interface
UV measurement interface
Sliding the screen,when without glasses,the screen will appear like
following
click then into the UV measurement interface,measurement the glasses.
Figure 3.5 UV measurement interface
Menu shows:
After entering into Menu, to press the corresponding button to change the
menu options, then back by pressing “exist”.
L/ R: to choose left
side or right side
Clearance: to clear
the saved data.

Auto lens meter operation manual
12
Figure 3.6 setting interface
Sheet 3.1 parameter options
Step 0.01D,0.12D,0.25D
Cylinder Mix,+,-
Lens Normal lens,hard lens
Prism No display,X-Y,P-B
Screen saver Closed,3minutes,5minutes ,
10minutes
Auto memory Closed, near to center, focus on
center
language ENGLISH,Chinese
Switch of PD On, off
Backlight adjust Light dark clock
Wallpaper gridding,halo,starry sky
Time setting Yes,no

Auto lens meter operation manual
13
Print and port setting Yes,no
ID setting Yes,no
Software type Newest
4 Operation
4.1 Assembling
(1)to check the attached parts: after opening the package, to check all
the attached parts (according to the attached list).
(2)to find a smooth place without direct sunshine and put down machine
well.
(3)to connect with power supply: to plug the power output injection of
adapter to the power injection at the back of machine.
(4)to put the grounding terminal well.
4.2 Test
(1)to turn on the power switch, just gentle touching on switch.
(2)the test data should be 0D without any lens. To turn on the power so
check if everything is OK.
Note: if all the data showed on measurement menu are not 0, then it means
that the protecting glass is dirty, which is in lens base. To blow off the
dust by the balloon. If it is still dirty, then to wipe it with lens cloth.
It should be cleaned every short time. Be sure to move lens base up while

Auto lens meter operation manual
14
the protecting lens is in cleaning.
4.3 Operation
4.3.1 Lens settings
1、to clarify the left side and right side of lens:
No PD measurement, the sliding nose pad frame should be move to left
side. L/ R keys will be workable.
In PD measuring, the sliding nose pad frame will direct the left
or right side and it will measure out the PD of left or right while
the L/ R keys are not workable.
If no need for choosing left or right side, there will be Sshowed
on the right up corner of measurement interface.
2、Lens settings
To put the lens on the lens base, and the convexity upward.
Figure 4.1 to put the measured lens

Auto lens meter operation manual
15
3、Lens fixing
To put the lens fixing frame on lens.
4.3.2 Lens measurement
1、Single vision lens measurement
(1) to focus the drone on the center
To move lens to make the drone(十) to the center. When the distance
between the drone and center less than 0.5△,the shape of the drone will
be as a cross (十);When the drone at the very place at center, the shape
of the drone will be a thicker cross(十). There are two ways to confirm
the measured data:
A:to press the memory key and the data will be saved. When data be saved,
the direction type of astigmatism +/- can be changed. To press clear key,
then it will restart the measurement.
B:automatical memory settings, the data will be saved automatically
according to the settings, then there is no need to press memory key anymore,
and the direction type of astigmatism +/- can be changed. To press clear
key, then it will restart the measurement.

Auto lens meter operation manual
16
Figure 4.2 measurement of cursor move on lens
Figure 4.3 measurement of center focusing
2、measurement to lens with frame
Normal measurement
(1)to press L/ R key to move the drone (十) to the center. When the
distance between the two less than 0.5△, the shape of the drone will be
as a cross(十);When the drone is just at the very point of center, the
shape will be a thicker cross (十). To press memory key (or automatical

Auto lens meter operation manual
17
memory set before) , the measured data will be saved.
(2)to press L/ R key to measure the other lens, and repeat action(1).
Figure 4.4 measurement of finished lens and save the data of left side
PD measurement: (no such function in Model A) The change of left or right
side should be done by the move of sliding nose pad frame.
(3)to rotate the lens table knob to move the lens table till touch the
bottom of lens frame, and move sliding nose pad frame to the center of lens
frame. To move the lens to make the drone(十) close to the center,when the
distance between the two less than 0.5△, the shape of the drone will be
as a cross(十);When the drone is just at the very point of center, the
shape will be a thicker cross (十). To press memory key (or automatical
memory set before) , the measured data will be saved.

Auto lens meter operation manual
18
Figure 4.5 measurement of finished lens and save the data of left and
right side
(4)to check the other lens, to move the sliding nose pad frame along with
the lens frame. Action as (1).
3、measurement of high index lens:
This machine is manufactured with standard green light source. There is
no need to set the Abbe number when measure the high index lens. The measured
data showed on the screen will be the correct one.
Table of contents