For easy installation of your Inolav faucet you will need:
· To READ ALL the instructions completely before beginning.
· To READ ALL warnings,care, and maintenance information.
®
You May Need
Pressure balance Valve Trim
Instructions
Owners Manual
Technical information:
Installation Considerations:
For best results, We recommends that this unit be installed by a
licensed, professional plumber.
Please read over these instructions thoroughly before beginning
installation. Make sure that you have all tools and supplies needed to
complete the installation.
To prevent scald injury, the maximum output temperature of the shower
valve must be no higher than 120°F. In Massachusetts, the maximum
output temperature can be no higher than 112°F.
Keep this booklet and the receipt (or other proof of date and place of
purchase) for this product in a safe place. The receipt is required should
it be necessary to request warranty parts.
•
•
•
•
Recommended water pressure : 15 - 75 PSI
Max. water pressure : 145 PSI
Recommended hot water temp. : 120 - 140°F
Max. hot water temp: 176°F
Flow rate: Up 5.4 GPM@60 PSI
Down 5.5 GPM@60 PSI
ASME A.112.18.1
For warranty issues call us at 1-855 472 4304 or send us an e-mail at warranty@inolav.com For questions call us at 1-855 472 4304 or visit our website at www.inolav.com
IS102-1-1 IS102-1-2

Flush the cold and hot water line
thoroughly before starting the installation.
Use threaded adapters/fittings (not
included) for connecting the water pipes
to the rough valve. Never solder directly
onto the threaded nipples of the rough
valve. When soldering CxC connections,
do not use excessive heat.
It is not necessary to remove the
pressure balance cartridge from the
valve during normal soldering connection.
The left side is the hot water inlet,
the right side is the cold water inlet,
up and down connections are the
mixed water outlets.
1.Prepare wall for rough-in valve
Finished wall must be within dimensions
shown in figure 1. The distance between
the back of the valve and the finished
wall must be between 2.52” and 3.03”.
Failure to comply with this tolerance
will result in improper fitment of trim
set.
3. Level the valve
Use a leveling indicator to align the
valve into proper position. Make sure
the valve is properly aligned in both
the vertical and horizontal direction.
At this step is also recommended to
double check the dimensions given
in step 1.
4. Check connections for leakage
Using a screwdriver close the service
stops located at each side of the
main cartridge. Open the main water
supply and inspect the connections
for leakage.
Close
Open
X
X2.52”~ 3.03”
For warranty issues call us at 1-855 472 4304 or send us an e-mail at warranty@inolav.com For questions call us at 1-855 472 4304 or visit our website at www.inolav.com
2.Connect the water pipes
WARNING: Soldering directly
onto the threaded nipples of
valves might cause breakage
or malfunctioning of the rough
valve. Failure to follow these
instructions will void the product’s
warranty.
Cold water
line
Hot water line
Threaded adapter
(fitting)
Mixed water outlet 1
Mixed water outlet 2
Threaded adapter
(fitting)

5. Trim installation preparation
7. Open the service stops
Use a screw driver in the counter
clockwise direction to fully open
the service stops.
8. Install the escutcheon (1) slowly all
the way against the finish wall.
Make sure you have these spareparts
before you go to nextstep.
Pressure balance Valve mixerhandle(1),
cap(2), handle screw(3),
diverter handle(4),
plastic washer(5),
plastic washer(6), cap(7),
handle screw(8), allen key(9),
escutcheon(10)
6. Remove the protective plastic
cover (1) and (2)
For warranty issues call us at 1-855 472 4304 or send us an e-mail at warranty@inolav.com For questions call us at 1-855 472 4304 or visit our website at www.inolav.com
1
1
WARNING: Stop unscrewing the service
stops once they have reached the full
travel. Forcing the service stops past
the limit can result in damage.
1
2
3
4
9. Install the handles
Install the diverter handle (1) making
sure plastic washer (4) is aligned as
shown. Adjust the diverter handle so
that it travels from 9 to 3 o’clock
(right to left) and vice versa. During
the midway point the diverter
handle (1) should be pointing
at 12 o’clock or up.
When the diverter handle points to
the left the upper outlet will be on
and when it turns to the right the
down outlet will go on.
Install the handle(3) to the pressure
balance cartridge and adjust
handle(3) direction to the downward
position.
Then use the allen key to tighten the
screws, and put on the screw caps.
1
2
1
6
78
9
10
2
3
4
5
Open

For warranty issues call us at 1-855 472 4304 or send us an e-mail at warranty@inolav.com For questions call us at 1-855 472 4304 or visit our website at www.inolav.com
Hot Cold
10. Test the handle
Lift the handle up to adjust volume
control. Turn the handle left and right
to adjust water temperature. Turning
the handle to the right increases the
cold water and to the left increases
the hot water.
1
23
123
457
Using the spanner to anti clockwise
stops (1).
Take out filter (2) and check Valve
(3).
Using clear water to rinse filter (2).
Slide filter (2) to check Valve (3),
then thread it to the valve body.
Using the spanner to connect stops
(1)to the valve.
Clean the stops filters:
1-
2-
3-
4-
5-
123
457
Anti clockwise the sleeve(1).
Using a spanner anti clockwise
locking nut (2).
Remove the diverter cartridge(3).
Remove the diverter cartridge:
1-
2-
3-
Anti clockwise the sleeve(4).
Using a spanner anti clockwise the
locking nut(5), then take it out.
Take out the pressure balance
cartridge (6).
Remove pressure balance
cartridge:
1-
2-
3-
Put diverter cartridge (3) to the
Valve, be noted the cartridge pin
should fix the hole of the valve.
Using a spanner clockwise locking
nut (2).
Clockwise the sleeve(1).
Install pressure balance cartridge
(6)to the valve.
Using a spanner clockwise the
locking nut (5).
Clockwise sleeve (4) to the valve.
Install the diverter cartridge:
1-
2-
3-
Install the pressure balance
cartridge:
1-
2-
3-
This manual suits for next models
1
Popular Control Unit manuals by other brands

MG
MG R7LWTU instruction manual

Plugwise
Plugwise TOM quick start

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-F FX5UC Series Hardware manual

UTC Fire and Security
UTC Fire and Security interlogix VT9930WDM Installation & operation instructions

Siemens
Siemens SINUMERIK 840D sl Configuration manual

CandCNC
CandCNC DCP-01 Setup and installation manual