SITING THE UNIT
To obtain maximum benefit from your fly killer it is most important that the unit is
sited in the correct position. The following points should be taken into
consideration: The unit should be sited, wherever possible, at 90° to the major
light source, e.g. largest window. Avoid siting too high; ideally the unit should be
sited with the base as near to 2 metres (6ft 6in) from the floor as possible.
Avoid siting the unit where air currents can blow flying insects away from the unit
e.g. near open doors.
The unit must not be sited so that the light source is obscured; if flying insects
cannot see it, the unit will not be fully effective.
The unit should not be sited above a food preparation surface, as the intention of
the unit is to attract insects away from such areas.
WARNING: To avoid exposure to UV light the unit should be sited one metre
away from any operator workstation.
INSTALLATION
WARNING: Before commencing installation ensure that all packaging materials
have been removed.
The EX55 should be mounted on a suitable wall using the wall plugs and screws
supplied with the unit. The unit is supplied with 2 metres of cable for connecting
to a suitable mains supply
INSTALLATION WARNING: THIS APPLIANCE MUST BE EARTHED
THIS APPLIANCE MUST BE FIXED IN
POSITION BEFORE ELECTRICITY IS
CONNECTED
Check that the electrical details on the unit correspond with the electrical supply
to which the unit is to be connected. An isolation switch must be used with a
contact separation of 3mm in each pole.