Inspiration S101 L User manual

2
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
BRAND CONFIGURATION TABLE............................................................................................................................................................3
SAFETY SIGN ..........................................................................................................................................................................................4
ATTENTION: SPA OWNER ......................................................................................................................................................................4
CONDITIONS OF WARRANTY AND CONSUMER OBLIGATIONS..............................................................................................................5
YOUR PERSONAL SPA DATA...................................................................................................................................................................6
IMPORTANT SAFETY INSTRUCTIONS .....................................................................................................................................................7
READ AND FOLLOW ALL INSTRUCTIONS ...............................................................................................................................................8
SAVE THESE INSTRUCTIONS...................................................................................................................................................................8
INSTALLATION INSTRUCTIONS...............................................................................................................................................................9
ELECTRICAL CONNECTION GENERAL INFORMATION ..........................................................................................................................11
NORTH AMERICAN (60HZ) MODELS....................................................................................................................................................12
1) 115 VOLT CORD CONNECTION....................................................................................................................................................13
2) 230 VOLT SUPPLY CONNECTION.................................................................................................................................................13
EUROPEAN (50HZ) MODELS ................................................................................................................................................................14
TYPICAL RESIDUAL CURRENT DETECTOR (RCD)...................................................................................................................................16
230 VOLT SUPPLY CONNECTION..........................................................................................................................................................16
CONVERSION FROM SINGLE SERVICE TO 3-SERVICE...........................................................................................................................18
WHAT’S INSIDE YOUR SPA...................................................................................................................................................................20
WHAT’S UNDER YOUR SPA (THE EQUIPMENT) ...................................................................................................................................23
START-UP.............................................................................................................................................................................................24
M8 TECHNOLOGY ................................................................................................................................................................................27
TP600 CONTROL PANEL USER GUIDE ..................................................................................................................................................28
SPATOUCH 3 ICON DRIVEN USER GUIDE .............................................................................................................................................41
IMPORTANT SAFETY INSTRUCTIONS FOR SPAS WITH AUDIO SYSTEMS..............................................................................................69
BLUETOOTH READY SYSTEM OPERATION ...........................................................................................................................................69
SPAS WITH BBA3 BLUETOOTH CONNECTION......................................................................................................................................70
ACCESSING FILTER CARTRIDGES..........................................................................................................................................................76
MAINTENANCE ....................................................................................................................................................................................77
FILTER SYSTEM.....................................................................................................................................................................................79
DRAINING YOUR SPA ...........................................................................................................................................................................80
WINTERIZING YOUR SPA......................................................................................................................................................................82
TROUBLESHOOTING YOUR SPA...........................................................................................................................................................83
WATER TREATMENT GUIDE.................................................................................................................................................................90

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
3
We have tried to compile a complete, easy to understand manual all about your spa and its' maintenance.
Years of research and development have gone into producing the superior quality product you have
purchased. Your spa is made from the highest quality material and latest technology available today. Pride
and meticulous attention to detail have resulted in the spa you have chosen. With proper care, your spa will
provide many years of comfort and pleasure.
Please take a few minutes now to read all of the instructions before you install your spa. This owner's manual will
help you understand your spa, so you will get the most from your investment. For service and advice, do not
hesitate to call your authorized dealer. Your questions will be welcomed by friendly and knowledgeable staff.
May you have as much pleasure and enjoyment using your new spa, as we had making it for you.
We understand there are many choices in the marketplace when you are
considering adding a spa to your home, so thank you for choosing a spa
by Leisure Manufacturing Inc. Enjoy!
Line
Model
Frame/Bottom
Filter
Keypad User Guide
S101 L
Polysteel/Tray
Ultraskim
TP600 Simplified
S102 L
Polysteel/Tray
Ultraskim
TP600 Simplified
S103 L
Polysteel/Tray
Ultraskim
TP600 Simplified
S104 L
Polysteel/Tray
Ultraskim
TP600 Simplified
S105 L
Polysteel/Tray
Ultraskim
TP600 Simplified
S106 L
Polysteel/Tray
Ultraskim
TP600 Simplified
S101 LSx
Polysteel/Tray
Ultraskim
SpaTouch 2
S102 LSx
Polysteel/Tray
Ultraskim
SpaTouch 2
S103 LSx
Polysteel/Tray
Ultraskim
SpaTouch 2
S104 LSx
Polysteel/Tray
Ultraskim
SpaTouch 2
S105 LSx
Polysteel/Tray
Ultraskim
SpaTouch 2
S106 LSx
Polysteel/Tray
Ultraskim
SpaTouch 2

4
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
Enclosed with this Owner’s Manual is a Safety Sign. This sign must be permanently installed in a location that is
visible to all spa users. It is the spa owner’s responsibility to remind all users about safe spa use, particularly
occasional users of the spa, who may not be aware of the various health and safety issues.
To obtain additional or replacement copies of the safety sign, contact your dealer.
In the immediate vicinity of the spa, a sign must be posted stating the following:
1) The spa’s address
2) Location of the nearest telephone with posted emergency numbers
3) Nearest available police department, fire department and ambulance/rescue unit

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
5
As a new spa owner, you have specific obligations in regards to the installation and safe use of this spa. Failure
to do so may result in a loss of warranty coverage not to mention personal injury to those using this spa.
Inspect the spa upon its arrival for damage. If you are being made aware of this for the first time, your
spa may not have been delivered in its original factory packaging. If this is the case, please take time to
inspect your spa and report any damage or missing items to your dealer.
1) Install the spa both physically and electrically, in accordance with any local codes.
2) Provide suitable access to all sides of the spa. Any custom built enclosure, either above or below a deck
surface, must be able to be removed with relative ease.
3) Provide sufficient work area around the spa’s perimeter especially the side the spa’s equipment is
located on.
4) Regularly check operation of the spa in regard to filtration, jet pump operation and the heating system.
5) Report any concern to the dealer. Any problem that arises towards the end of particular warranty
coverage should be documented and reported to the dealer
6) Maintain the water’s chemical balance and clean/replace the system’s cartridge filter(s) as instructed
by the dealer and/or Leisure Manufacturing Inc.
7) Drain and refill the spa on a regular basis as instructed by the dealer and/or Leisure Manufacturing Inc.
8) Winterize and store the spa and its’components in accordance with the manufacturer’s printed
instructions.
9) Care for and maintain the spa cabinet, hard cover and acrylic surface as outlined in these instructions.
10) Ask your dealer to record the spa’s serial number on your bill of sale.
11) Provide a copy of your bill of sale, if requested by the dealer or Leisure Manufacturing Inc.

6
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
Before you begin the installation of your new spa please take a few minutes to fill out the details of your spa.
This information will become invaluable later should you have a question for your dealer or should you need to
make a warranty claim. Ask your dealer to assist you in recording this information.
Model Year
Model Name/Number
Spa Serial#
Jet Pump(s) Size (HP, SPL, Watts etc.)
Heater size (kw)
Filter Cartridge (Model Number/Size)
Topside Control/Keypad
Spa Pack Model #
Spa Pack Serial #
Dealer Name
Date of Purchase
We strongly recommend that you attach your bill of sale to this manual after installation is complete. Keep it
in a safe place for future reference. You may also wish to attach any notes you have made about the dealer
delivery, dealer start up demo or any other notes that may be of benefit in the future.

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
7
DANGER: Risk of Accidental Drowning. Extreme caution must be exercised to prevent unauthorized access by
children. To avoid accidents, ensure that children cannot use this spa unless they are supervised at all times.
DANGER: Risk of Injury. The suction fittings in this spa are sized to match the specific water flow created by the
pump. Should the need arise to replace the suction fittings or the pump, be sure that the flow rates are
compatible.
Never operate spa if the suction fittings are broken or missing. Never replace a suction fitting with one rated less
than the flow rate marked on the original suction fitting.
DANGER: Risk of Electric Shock. Install at least 5 feet (1.5m) from all metal surfaces. As an alternative, a spa may
be installed within 5 feet of metal surfaces if each metal surface is permanently connected by a minimum 8
AWG (8.4mm2) solid copper conductor to the wire connector on the terminal box that is provided for this
purpose.
DANGER: Risk of Electric Shock. Do not permit any electrical appliance, such as a light, telephone, radio, or
television, within 5 feet (1.5m) of a spa.
WARNING: To reduce the risk of injury:
a) The water in a spa should never exceed 40°C (104°F). Water temperatures between 38°C (100°F) and
40°C are considered safe for a healthy adult. Lower water temperatures are recommended for young
children and when spa use exceeds 10 minutes.
b) Since excessive water temperatures have a high potential for causing fetal damage during the early
months of pregnancy, pregnant or possibly pregnant women should limit spa water temperatures to
38°C (100°F).
c) Before entering a spa, the user should measure the water temperature since the tolerance of water
temperature-regulating devices varies.
d) The use of alcohol, drugs, or medication before or during spa use may lead to unconsciousness with the
possibility of drowning.
e) Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system
problems or diabetes should consult a physician before using a spa.
f) Persons using medication should consult a physician before using a spa since some medication may
induce drowsiness while other medication may affect heart rate, blood pressure, and circulation.
CAUTION:
Maintain water chemistry in accordance with the manufacturer's instructions.

8
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
When using this equipment, basic safety precautions should always be followed. Including the following:
a) A green coloured terminal or a terminal marked G, GR, Ground, Grounding or the international
grounding symbol is located inside the supply terminal box or compartment. To reduce the risk of
electric shock, this terminal must be connected to the grounding means provided in the electric supply
service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this
equipment.
b) At least two lugs marked "BONDING LUGS" are provided on the external surface or on the inside of the
supply terminal box or compartment. To reduce the risk of electric shock, connect the local common
bonding grid in area of the hot tub or spa to these terminals with an insulated or bare copper
conductor not smaller than No.6 AWG.
c) All field-installed metal components such as rails, ladders, drains or other similar hardware within 3m
(10ft) of the spa or hot tub shall be bonded to the equipment grounding bus with copper conductors
not smaller than No.6 AWG.
DO NOT connect your spa to an extension cord.
Hyperthermia
Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal
temperature of the body reaches a level several degrees above the normal body temperature of 37°C (98°F).
The symptoms of hyperthermia include drowsiness, lethargy, and an increase in the internal temperature of the
body. The effects of hyperthermia include:
•Unawareness of impending hazard
•Failure to perceive heat
•Failure to recognize the need to exit spa
•Physical inability to exit spa
•Fetal damage in pregnant women
•Unconsciousness and danger of drowning
WARNING:
The use of alcohol, drugs or medication can significantly
increase the risk of fetal hyperthermia.

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
9
Remember, your new spa is a powerful piece of electrical and plumbing equipment. You owe it to yourself,
your family and your friends to install it correctly and safely. Before attempting to hook-up or use your spa,
please read the following instructions.
ATTENTION:
This spa is intended for outdoor use, however it can be installed indoors
when precautions are taken to ensure the spa is installed and located
in such a manner that any water that could leak, splash or be released as humidity
will drain away harmlessly.
Your spa is completely self-contained. Therefore, you can situate it just about anywhere; on a patio, in or on a
deck, in a basement or sunroom. It comes completely pre-plumbed and water tested from the factory. Never
lift or carry the spa by the plumbing. Damage could occur which would not be covered under warranty.
You should take into account the following when selecting prospective spa sites in order to maximize
enjoyment.
To avoid any personal injury or damage to your spa, have 4-5 people ready to assist you to move the spa to its'
final location. Use a moving dolly and/or straps to more evenly distribute the spa's weight. Never lift or carry the
spa by its' plumbing.
Local codes
Local building, property and electrical codes may affect your installation.
Delivery access to
location
Gates, overhangs, fences, gas meters, and AC units may become obstructions.
You may need to access from a neighbour's yard or employ a crane.
Vegetation in spa area
Trees, bushes, flowers etc. can all add to spa maintenance.
Spa location relative to
buildings
The location could add to your spa maintenance (removing snow from cover)
and increase operating costs.
Fences, tree lines
More privacy during use and serves as a wind break but may also add more
maintenance.
Spa step out location
Any surface that is slippery when wet could be dangerous for bathers both
entering and exiting the spa.
Spa Direction
View when using a lounger & ease of access for servicing.
Downspouts and natural
drainage of land
These may flood the spa area, damage spa or create a safety hazard to bathers.
Outside water supply and
draining location
You will need a place to safely drain the spa and a way to refill it easily.
Optional accessories
These may take up added space that you must plan for (cover remover/holder).

10
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
Whatever the support is, it must be:
a) A continuous, level surface, above grade, capable of handling 80 lbs. per sq. ft. that will not be
compromised by changes in the water table or water sitting in the area.
b) Such that the weight of the spa, water and bathers is not supported by the spa lip.
c) In full contact with the bottom of the spa
Concrete Pad
4" to 6" thick with provision for run off
Patio Stones, Pavers etc.
Levelled with proper preparation of the earth
Wooden Deck Floor
Incl. centre support uprights in concrete and joists spaced 12" on centre
Engineered Plastic Spa Pad
Following pad manufacturer's instructions
Unacceptable Spa support bases include crushed gravel, stone dust, bare earth, platform built directly onto
earth. Damage caused by improper spa installation will void factory warranty.
Do NOT locate your spa in a low run-off area since melting snow or rain can cause pump and equipment
damage. WATER SHOULD ALWAYS DRAIN AWAY FROM THE SPA.
See next page for dimensions that can be used to determine the proper location of submerged conduits in
concrete slab installations. All dimensions are made from the outside of the spa's frame with the access panels
removed.

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
11
If your intent is to bring a conduit and power wires up under the spa we suggest
that it enter the spa cavity in the front, left corner; 6” (15cm) Dimension A in
from the left and 6” (15cm) Dimension B up from the front. See A & B on the
diagram below. This location will allow you to stay clear of spa pumps and other
equipment while giving you a short and easy access to the left side of the spa
pack, where the electrical entry hole and terminal block are located.
•You may enter the spa cavity at any other point around spa provided you have reviewed the location and
determined there is no interference. You may also decide to enter at an adjoining wall (depending on the
positioning of the spa) and route a conduit along the spa kicker. Ask your electrician for his/her advice
in these matters.
•In all cases the best side for entry of the supply cable is the side to your left when you are standing at the
equipment panel.
•Right side entry is possible; however, this may involve additional supply cable, parts and time.
Polysteel Frame with Polyethylene Bottom and Polysteel Panels
a) You can choose to notch the polysteel panel so you can pass the cable/conduit through and still be
able to remove/replace the panel for servicing. You should consider securing the cable or conduit to
the spa’s metal frame where cable/conduit passes through the cabinet.
b) You may also route a cable up under the corner. The curved panel is flexible enough and there is
enough space to run the cable this way. Removing the corner may help you to do this easier.
c) On a concrete pad where you have a conduit or cable coming up within the perimeter of the spa, you
can easily cut an opening in the polyethylene bottom to access the cable or conduit/wires. See above
table for recommended opening location.
You may wish to insulate any opening or cut-out you make in the spa’s cabinet panel or corner or bottom to
keep cold air and small animals out.

12
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
Please note the following important information:
When using this electrical equipment, basic safety instructions should be followed, including the following:
Read and Follow ALL Directions
1) Electrical installation must be carried out by a qualified electrician strictly in accordance with
local governing codes.
2) A terminal marked "ground" is located within the control box. To reduce the risk of electric
shock this terminal must be connected to the grounding means provided in the electric supply
service panel with a continuous copper wire equivalent in size to the circuit conductors
supplying the equipment.
3) At least two lugs marked "bonding lugs" are provided on the external surface of the control
box. To reduce the risk of electric shock connect the local common bonding grid in the area
of the hot tub or spa to these terminals with an insulated or bare copper conductor not smaller
than No. 6 AWG.
4) All field installed metal components such as rails, ladders, drains or other similar hardware
within 3m (10 ft.) of the spa or hot tub shall be bonded to the equipment grounding bus with
copper conductors not smaller than No. 6 AWG.
5) Test the ground fault circuit interrupter before each use of the spa.
6) Before servicing any electrical components of the system make sure that the power supply is
switched off.
ATTENTION: ELECTRICIAN & SPA OWNER
PICO FUSE
Balboa Spa packs contain a special fuse, referred to a “Pico fuse”.
This special fuse is designed to open (burn out) if:
a) There is any problem with how the electrical supply is connected
b) There is a power surge to the spa pack
This fuse is not replaceable and the entire spa pack is considered destroyed.
WARNING!
THIS IS NOT A CONDITION THAT IS COVERED UNDER THE
SPA PACK MANUFACTURER’S WARRANTY OR
LEISURE MANUFACTURING’S COMPREHENSIVE SPA WARRANTY.

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
13
This unit has been built, tested and approved with a cord connected 115VAC built in Ground Fault Circuit
Interrupter (GFCI).
The cord must only be plugged into a receptacle that is connected to a
dedicated 15A breaker or fuse.
DO NOT extend the connection by the use of an extension cord. This will
void the warranty and could cause damage to the spa and its’ users.
GFCI Test Procedure:
1. With the GFCI plugged into a grounded 115VAC, 15A outlet
press the yellow TEST button.
2. The spa should shut off and a small light between the TEST and
RESET buttons should be lighted.
3. Press the red RESET button to reset the GFCI and start the spa.
FAMILIARIZE yourself with the test procedure for the GF CI. TEST the GFCI upon every use of the spa.
If the GFCI does not shut the spa off when the TEST button is pressed or does not start up when the RESET button
is pressed DO NOT USE THE SPA. Contact your dealer and/or a qualified electrician immediately. Take steps to
ensure that no person(s) can use the spa while the problem is being reviewed and corrected.
Note: In new installations, GFCI trippings due to mis-wiring are very common.
If the breaker is properly wired, GFCI trippings can occur when the total amount of current drawn by the spa
exceeds the rating of the breaker. Such an occurrence, however, is very unlikely, since each output of the spa
pack is individually fused and fuses will blow before the GFCI trips. A current leak to the ground will also make
the GFCI trip. If one or more of the components is faulty and there is a leak of more than 5 mA, the GFCI will trip
to prevent electrocution.
CAUTION:
Electrical installation must be carried out by a qualified electrician
strictly in accordance with local governing codes.
Use only Class A Ground Fault Circuit Interrupter.
BP SERIES SPA PACK
Power Requirements
240VAC, 60Hz, Class A GFCI-protected service
4 wires (Hot-Line 1, Hot-Line 2, Neutral, Ground)
For current requirements & breaker rating see nameplate on spa.
Power Up Screen
Each time the system powers up, a series of numbers is displayed. After the start-up
sequence of numbers, the system will enter Priming Mode. Next, refer to the User
Guide for your keypad at the back of this manual.

14
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
Several different models of GFCIs are available on the
market. Note that our illustrations are generic.

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
15
Please note the following important information:
When using this electrical equipment, basic safety instructions should be followed, including the following:
Read and Follow ALL Directions
(1) This spa must be connected to an RCD (Residual Current Detector) with a residual operating current not
exceeding 30mAmps.
(2) Electrical installation must be carried out by a qualified electrician strictly in accordance with local
governing codes.
(3) A terminal marked "ground" is located within the control box. To reduce the risk of electric shock this
terminal must be connected to the grounding means provided in the electric supply service panel with
a continuous copper wire equivalent in size to the circuit conductors supplying the equipment.
(4) At least two lugs marked "bonding lugs" are provided on the external surface of the control box. To
reduce the risk of electric shock connect the local common bonding grid in the area of the hot tub or
spa to these terminals with an insulated or bare copper conductor not smaller than No. 6 AWG.
(5) Test the RCD before each use of the spa, according to the manufacturer's instructions.
(6) Before servicing any electrical components of the system make sure that the power supply is switched
off.
(7) Keep the door closed in order to provide IPX5 protection to the electrical compartment.
Any opening made through the spa enclosure for the entry of input cables/wires,
must be made watertight to preserve the IPX5 rating of the appliance.
ATTENTION: ELECTRICIAN & SPA OWNER
PICO FUSE
Balboa Spa packs contain a special fuse, referred to a “Pico fuse”.
This special fuse is designed to open (burn out) if:
c) There is any problem with how the electrical supply is connected
d) There is a power surge to the spa pack
This fuse is not replaceable and the entire spa pack is considered destroyed.
WARNING!
THIS IS NOT A CONDITION THAT IS COVERED UNDER THE
SPA PACK MANUFACTURER’S WARRANTY OR
LEISURE MANUFACTURING’S COMPREHENSIVE SPA WARRANTY.

16
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
A residual current device (RCD,) is the generic term for a device that monitors the
current in the line conductor and the neutral conductor of a circuit in an earthed
system.
In a circuit that’s operating properly, the vector sum of the live and neutral current
values added together will be zero. Current flowing to earth, due to a line earth fault,
will return via the earth conductor, and regardless of load conditions, will be registered
as a fault. This current flow will give rise to a residual current that will be detected by the
device. If the residual current exceeds the rated sensitivity of the RCD, it will
automatically activate a tripping of the faulty circuit.
Power Requirements:
Single Service [3 wires (line, neutral, ground)]
230VAC, 50/60Hz, 1p, 16A (Circuit Breaker rating =20A max.)
Single Service [3 wires (line, neutral, ground)]
230VAC, 50/60Hz, 1p, 32A (Circuit Breaker rating =40A max.)
IMPORTANT: If you want to run this spa pack on a
1 x 32 Amp single service you must:
a) Move dipswitch #2 on switchbank S1
to the ON position
b) Move dipswitch #5 on switchbank S1
to the OFF position
See wiring diagram (back of cover for spa pack)
for switchbank location
<- Two Pole RCD
Typical specifications are as follows:
Residual Current Devices ( RCD’s ) range
Sensitivity - from 10 to 500mA
Voltage - 2 poles : 230V; 3/4 poles: 230/400V
Connection capacity
- 25A: 6/10 mm² (flexible/ rigid cable)
- 40,60A: 16/25 mm²
- 80,100A: 35/50 mm²
<- Four Pole RCD
SRBP601ESpaPack

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
17
Power Requirements:
Single Service [3 wires (line, neutral, ground)]
230VAC, 50Hz, 1p, 32A (Circuit Breaker rating =40A max.)
Dual Service N/A
230VAC, 50/60Hz, 1p, 32A (Circuit Breaker rating =40A max.)
3-Service [5 wires (line 1, line 2, line 3, neutral, ground)]
400VAC, 50Hz, 3p, 16A (Circuit Breaker rating =20A max each phase line.
IMPORTANT –Service must include a neutral wire, with a line to neutral voltage of 230VAC.
SRBP21X
SpaPack–SingleService

18
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
1. Remove the jumper wire from J51 (Area 1) to J88 (Area 2)
2. Remove the jumper wire from J52 (Area 1) to J62 (Area 2)
3. Move the jumper wire attached to J60 from J36 in Area 3 to J45 in Area 4. (J60 to J45)
4. Move the jumper wire attached to J41 from J12 in Area 3 to J79 in Area 4. (J41 to J79)
5. Set DIP Switches A2 and A5 to OFF.
6. Terminal block must be wired according to the 3-Phase illustration on the wiring diagram
1. Line 1 –Brown
2. Neutral-Blue
3. Line 2 –Brown
4. Line 3 - Brown
SRBP21X
Spa Pack - 3-Service
Power Up Screen
Each time the system powers up, a series of numbers is displayed. After the start-up sequence of numbers, the
system will enter Priming Mode. Next, refer to the User Guide for your keypad at the back of this manual.

Inspiration Spas 2021 Owner’s Manual DOC: OM-INSPIRATION-21G
19
Wire Size and Over Current Protection (Canada/US)
Amp rating of spa
Supply Wire type and size
Over Current
Protection (amps)
More than
To
60C copper, AWG
75C copper, AWG
16
20
10
10
25
20
24
10
10
30
24
28
8
10
35
28
32
8
8
40
32
36
6
8
45
36
40
6
8
50
40
48
4
6
60
Note: If your GFCI trips immediately on start-up or during the opening use of the spa, DO NOT USE THE SPA and
take precautions to ensure that no one uses the spa, while you contact your dealer/electrician. GFCI trips on
newly installed spas are predominantly caused by mis-wired GFCIs.
SPECIAL NOTE: DISCONNECT SWITCH
This unit must be connected to a disconnect that de-energizes power to the entire unit for servicing,
maintenance or the like. The disconnect switch, with marked "OFF" position, must be located within sight from
the equipment and at least 5ft. (1.52m) from the inside walls of the spa.
SPECIAL NOTE: EMERGENCY SWITCH
This unit is intended for use in a single family dwelling. When used in locations other than a single family
dwelling, a clearly labelled emergency switch, readily accessible to the occupants and at least 5ft. (1.52m)
away from the unit, shall be provided as part of the installation.
Wire Size and Over Current Protection (Europe)
Total Ampere Rating of
Power System
Minimum Wire Size
Use Copper ONLY
With 90°C Insulation
Ampere Rating of
RCD Circuit-breaker
OA to 16A
#12 AWG
20
16A to 20A
#10 AWG
25
20A to 24A
#10 AWG
30
24A to 28A
#8 AWG
35
28A to 32A
#8 AWG
40

20
DOC: OM-INSPIRATION-21G Inspiration Spas 2021 Owner’s Manual
A variety of jet sizes and internal styles are used in unique seating patterns to achieve superior hydrotherapy in
individual spa models. Therefore, not every jet described or pictured below is in every model. Not all jet internal
styles are available in all jet sizes.
To adjust the water volume, simply turn the jet face clockwise to the off position or counter clockwise to the
maximum position. If you move too hard to maximum you will release the internal from the jet body.
Jet Type
Size
Adjustable Flow
Where it is most often used
Ozone/Cluster
1 ½” (38mm)
No
Seat backs, neck & shoulders, palm jets
Air Max
2 1/8” (54mm)
Yes
Specialty seat backs
Cluster
2 3/8”(56mm)
Yes
Palm jets, loungers, seat backs, calves, neck collars
Mini
3 1/4” (84mm)
Yes
Seat backs, footwells, loungers
Poly
3 3/4”(92mm)
4 ⅜” (105mm)
Yes
Seat backs, footwells, loungers
Power
5 ¼” (133mm)
Yes
Seat backs, footwells, loungers
Nozzle Type
Hydrotherapy Effect
Description
Fixed Stream
A steady, non-adjustable stream of water.
Air Max
A soft tissue therapy jet. Draws more air than a
standard jet. Solo, triple or multiple streams of air &
water mixed for soothing comfort. (Not available on
all models).
This manual suits for next models
11
Table of contents
Other Inspiration Medical Equipment manuals