USER MANUAL
EPRO RACK 1.1K-3.4K
____________________________________________________________________________________________
(120217_ENG) Integra EPRO RACK 1.1K-3.4K - 25
15. WARRANTY AND SUPPORT
Support: When a failure or problem is detected please check troubleshooting table in this manual. If problem cannot be solved please contact
authorized service center or authorized dealer.
Batteries: Rechargeable batteries can be charged and discharged hundreds of times. However they will eventually wear out. This is not a
defect or failure so that batteries wear out is not covered by warranty.
Battery lifetime will depend of operative conditions like working temperature and type and frequency of discharging cycles. Higher the
temperature shorter will be the lifetime. Frequent and deep discharging cycles also will short lifetime. For critical applications batteries should
be revised and replaced periodically.
Long storage without required recharging will wear out batteries. This situation is not covered by this limited warranty since this is not
considered as a defect. Check recharging instructions on user manual.
Conditions Limited Warranty “PRO11”
1.- Subject to the conditions of this limited warranty, this product is warranted to be free from defects in materials and workmanship at the time
of its original purchase by end user.
In Europe warranty time is 2 years on electronic parts and batteries.
In America warranty time is 1 year on electronic parts and 1 year on batteries.
Standard warranty times could vary depending on country/region or extended by purchasing warranty options. Please check warranty
conditions by country/region in our web www.integra-ups.com.
2.- If during the warranty period, this product fails to operate under normal use and service, due to defects in materials or workmanship,
authorized distributor or service center will, at their option, either repair or replace the product in accordance with terms and conditions
stipulated herein. Transportation expenses are not covered by this limited warranty.
3.- Warranty is valid only if the original purchasing document issued to original purchaser by authorized distributor or dealer, specifying date of
purchase, serial number and name of the dealer, is presented with the product to be revised. INTEGRA and authorized partners reserve the
right to refuse warranty service if any of this information has been removed, changed or missing in original purchasing document.
4.- If product is repaired or replaced, repaired or replaced product will be warranted for the remaining time of the original warranty or for 90
days from date of repair or replacement, whichever is longer.
5.- INTEGRA or their distribution/service partners reserve the right to charge handling fee or transportation costs if returned product is free of
failure or out of warranty period because any of the reasons described in this warranty.
6.- If product is out of warranty a reparation or replacement proposal will be sent to the user for his approval. If proposal is not accepted
service center will tryto send back product to the user with transportation costs covered by user. If delivery fails twice, product will be hold to
let user pick up the product. After this period product would be disposed by service center and user will not be able to rises any claim.
7.- Rechargeable batteries will definitively wear out even under normal operation and conditions. This is not a defect or failure so that it is not
covered by this warranty.
8.- Warranty does not cover product failures caused by: improper storage or longer than 6 months storage without required recharging,
inadequate installation or maintenance, misuse, accidents, fire or floods. In these cases warranty will be considered void.
9.- This warranty does not cover product failures caused by installations, modifications or repair or opening of the product performed by non
authorized person.
10.- This product can include protection devices like input fuse or input breaker. Activation of this kind of devices is not a failure it is caused by
an improper product installation. Input fuse or breaker can be easily reset or replaced by user.
11.- This warranty does not cover damages produced during transportation from user to technical service caused by improper packing of the
product by user.
12.- Warranty time could be extended to 3 years depending on market or products. Contact your authorized dealer for additional information.
13.- Warranty terms and conditions cannot be modified or extended by third parties without written approval of INTEGRA.
Limited Warranty “PRO11”
- If hardware product fail to work as warrantedabove, themaximum liability of INTEGRA under this limited warranty is expressly limited to the
lesser of the price you have paid for the product or the cost of repairing or replacement of any hardware components that malfunction in
conditions of normal use.
- In no event will INTEGRA be liable for any damages caused by the product or the failure of the product to perform, including any lost profits
or savings or special, incidental, or consequential damages. INTEGRA is not liable for any claim made by a third party or made by you for a
third party.
- INTEGRA does not warrant that the operation of this product will be uninterrupted or error-free. INTEGRA is not responsible for damage that
occurs as a result of your failure to follow the instructions intended for this hardware product.
USER MANUAL
EPRO RACK 1.1K-3.4K
____________________________________________________________________________________________
(120217_ENG) Integra EPRO RACK 1.1K-3.4K - 26
16. SPECIFICATIONS TABLE (For Models 120Vac and 220Vac)
INPUT / ENTRADA
FrequencyRange /Rango deFrecuencia
OutputRegulation/RangodeSalida:
Eco Mode
ACMode /ModoNormal
Battery Mode / Modo Batería
Technology/Tecnología
Qty&Type/Cantidad&Tipo (Model 220V):
Qty&Type/Cantidad&Tipo (Model 120V):
Charging Voltage/Voltajedel cargador(Model 220V):
Charging Voltage/Voltajedel cargador(Model 120V):
TypicalRechargeTime/T.deRecarga
ChargingAmps/CorrientedeCarga
Prog.Outlets/SalidasProg.(Model:230Vac) *N2
Prog.Outlets/SalidasProg.(Model:120Vac) *N2
DxWxH / Prof.X Ancho X Altura (mm)
Net Weight /Peso Neto (kgs)
OperatingTemperature/Temp.deOperación
2.250VA/1.600W 3.400VA/2.400W
3x12V-7AH 6 x12V-9AH 6x12V-9AH
41.0 VDC +/- 1% 82.1 VDC +/-1% 82.1 VDC +/-1%
Range /Rango -Vac @ 50%load Model120V: 50Vac-150Vac / Model 220V:110Vac-300Vac
40Hz-70Hz
EPRO-RACK 1.7K 2.25K 3.4K
Capacity/Capacidad 1.700VA/1.200W
PowerFactor/FactordePotencia >0.99@100%load
Input Current THDi / THDi de Corriente de Entrada < 7% @ 100% load
Range /Rango -Vac @ 100%load Model 120V: 80Vac-150Vac / Model 220V: 160Vac-300Vac
OUTPUT /SALIDA
VoltageOutput/ Voltajede SalidaAC: (*N1)Model 120V:110/115/120/127Vac - Model220V: 208/220/230/240Vac
+/-3%
Frequency/Frecuencia (Batt.Mode) (*N3) 50 Hz +/- 0.25 Hz - 60Hz +/- 0.3 Hz
>85% >88%
CurrentCrestRatio/FactordeCresta 3:1@100%load
Harmonic Distortion/Dist.Armónica (THDv) <3%@LinearLoad/CargaLineal / <6%@NoLinearLoad/Cargano Lineal
AC to Inverter / Tiempo de AC a Inversor 0ms
OVERLOAD/ SOBRECARGA 100%~110%:(warning-alarma)/ 110%~130%:1min:bypass/ >130%:1s:bypass
100%~110%:(warning-alarma)/ 110%~130%: 30s:shutdown / >130% :1s:shutdown
BATTERIES/BATERIAS
Waveform / Forma de Onda Pure Sinewave /Sinusoidal Pura
EFFICIENCY / EFICIENCIA >93% >93%
CMode/ModoAC
UPSstatus,Loadlevel,Battery,Input/Outputvoltage,Dischargetimer,and Faultconditions
EstadodelUPS,Consumo,Baterías,VoltajeEntrada/Salida,Autonomía,Diagnostico Fallas
SealedLeadAcid VRLA-AGM / Sellada deLibreMantenimientoVRLA-AGM
3x12V-7AH 4 x12V-9AH 6x12V-9AH
4Hours for 90%capacity/4 Horaspararecuperar el90% decarga
1.0A(Max.)
CEE7/4(Schuko) x 1
PHYSICAL / FISICAS: UPS RACK Type
ALARM / ALARMAS
BeepAlarm /Alarma sonora: BatteryMode,Low battery,Overload,Failure / Modo Batería,Bajabatería,Sobrecargas,Falla
41.0 VDC +/- 1% 54.8 VDC +/-1% 82.1 VDC +/-1%
INDICATORS /INDICADORES
LCD/PantalladeCristalLiquido(LCD)
Std.Outlets/SalidasEstándar(Model:120Vac) NEMA5-15R x 2 NEMA5-20R x 4 NEMA5-20R x 2
Std.Outlets/SalidasEstándar(Model:230Vac) CEE7/4 (Schuko)x1 CEE7/4 (Schuko)x1 CEE7/4 (Schuko)x1
CEE7/4(Schuko) x 1 CEE7/4(Schuko)x 1
NEMA5-15R x 2 NEMA5-20R x 4 NEMA5-20R x 2
438x88x480[2U] 438x88x600[2U] 438x88x600[2U]
18.5 20.6 29
OPERATIONAL CONDITIONS/ CONDICIONES DEOPERACI