Integrated Power Designs REL-185 Series User manual

INTEGRATED
POWER DESIGNS
300 Stewart Road
Wilkes-Barre, PA 18706 USA
Phone: (570) 824-4666
Web: www.ipdpower.com
Email: sales@ipdpower.com
Fax: (570) 824-4843
DRAWING NO: 1080023
REVISION: 34
REL-185 SERIES OPERATING INSTRUCTIONS
INPUT RATING: 100-240VAC, 4 A, 50-60 Hz.
OUTPUT RATING: 185 Watts Maximum Total Continuous Output Power with 300 LFM Forced Air.
135 Watts Maximum Total Continuous Output Power Convection Cooled.
110 Watts Maximum Total Continuous Output Power Convection Cooled with Chassis and Cover.
MODEL LISTING:
NOTES: 1. Total current from Outputs 1 and 2 must not exceed 20 Amps with convection cooling.
2. Total current from Outputs 3 and 4 must not exceed 3 Amps with convection cooling.
3. Rated 15 Amps maximum with convection cooling.
4. Rated 27 Amps maximum with convection cooling.
5. A suffix may be added to the model number to indicate the following optional configurations:
(CH-chassis, CO-cover, IO-isolated outputs, RE-remote inhibit, TS-terminal strip)
6. Output is ES3 type.
Model
Output 1(1)
Output 2(1)
Output 3(2)
Output 4(2)
REL-185-4001
+3.3VDC/20A(3)
+5VDC/10A
+12VDC/2A
-12VDC/2A
REL-185-4002
+5VDC/20A(3)
+3.3VDC/10A
+12VDC/2A
-12VDC/2A
REL-185-4003
+5VDC/20A(3)
+3.3VDC/10A
+15VDC/2A
-15VDC/2A
REL-185-4004
+5VDC/20A(3)
-5VDC/10A
+12VDC/2A
-12VDC/2A
REL-185-4005
+5VDC/20A(3)
-5VDC/10A
+15VDC/2A
-15VDC/2A
REL-185-4006
+5VDC/20A(3)
+24VDC/3A
+12VDC/2A
-12VDC/2A
REL-185-4007
+5VDC/20A(3)
+24VDC/3A
+15VDC/2A
-15VDC/2A
REL-185-4008
+3.3VDC/20A(3)
+6.7VDC/5A
+12VDC/2A
-6.7VDC/2A
REL-185-4009
5VDC/15A
12VDC/4A
28VDC/0.8A(6)
12VDC/2A
REL-185-4010
5VDC/20A
5VDC/10A
24VDC/1A(6)
24VDC/1A(6)
REL-185-3001
+5VDC/20A(3)
+12VDC/5A
-----
-12VDC/3A
REL-185-3002
+5VDC/20A(3)
+15VDC/4A
-----
-15VDC/3A
REL-185-2001
+3.3VDC/20A(3)
+5VDC/10A
-----
-----
REL-185-2002
+5VDC/20A(3)
+12VDC/8A
-----
-----
REL-185-2003
+5VDC/20A(3)
+24VDC/4A
-----
-----
REL-185-2004
+12VDC/10A
-12VDC/4A
-----
-----
REL-185-2005
+15VDC/8A
-15VDC/5A
-----
-----
REL-185-2006
+15VDC/6A
+24VDC/4A
-----
-----
REL-185-2007
+35VDC/3.5A
+12VDC/5.2A
-----
-----
REL-185-1001
2.5VDC/37A(4)
-----
-----
-----
REL-185-1002
3.3VDC/37A(4)
-----
-----
-----
REL-185-1003
5VDC/37A(4)
-----
-----
-----
REL-185-1004
12VDC/15.4A
-----
-----
-----
REL-185-1005
15VDC/12.3A
-----
-----
-----
REL-185-1006
24VDC/7.7A
-----
-----
-----
REL-185-1007
28VDC/6.6A
-----
-----
-----
REL-185-1008
48VDC/3.8A
-----
-----
-----
REL-185-1009
6.3VDC/29A
-----
-----
-----
REL-185-1010
31VDC/6A
-----
-----
-----
DECLARATION OF CONFORMITY
Manufacturer: Integrated Power Designs, Inc.
Manufacturer’s Address: 300 Stewart Road, Wilkes-Barre, PA 18706 USA
Product Type: Switchmode AC-DC Power Supply
Declares all models listed above including all options are in compliance with the following European Community Directives:
Low Voltage Directive 2014/35/EU of 26 February 2014
RoHS Directive 2015/863/EU of 31 March 2015
As well as with the requirements set out in the Laws of the United Kingdom relating to and applying the following standards:
Electrical Equipment (Safety) Regulations 2016 SI No. 1101
BS EN 62368-1:2014
Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations 2012 SI No. 3032 + 2019 SI No.492
In addition, all models are Certified to be in compliance with applicable requirements of UL 62368-1:2014, ANSI/AAMI ES60601:2005/(R) 2012, IEC 62368-
1:2014 and IEC 60601-1:2005/A1:2012 including all EU national deviations, CAN/CSA-C22.2 No. 62368-1-14, CAN/CSA- C22.2 No. 60601-1:2014, EN
62368-1:2014 and EN 60601-1:2006/A1:2013.
BY:
Steven Thompson- President
EUROPEAN CONTACT:
UK CONTACT:
Compumess Elektronik GmbH
Lise-Meitner-Strasse 1
85716 Unterschleiβheim
Telephone (089) 32 15 01-0
ALL PSU LTD
Laser Quay, Culpeper Close
Rochester Kent ME2 4HU
Tel : 01634 725527
PLACE:
Integrated Power Designs
300 Stewart Road, Wilkes-Barre, PA 18706 USA
DATE:
February 16, 2021

INTEGRATED
POWER DESIGNS
300 Stewart Road
Wilkes-Barre, PA 18706 USA
Phone: (570) 824-4666
Web: www.ipdpower.com
Email: sales@ipdpower.com
Fax: (570) 824-4843
DRAWING NO: 1080023
REVISION: 34
CLASSIFICATION: 1. Protection against electric shock –Class I.
2. Protection against harmful ingress of water –IPXO (Non-protected), ordinary.
3. Methods of sterilization –None.
4. Suitability for use in an oxygen rish environment –End user responsibility, not evaluated.
5. Mode of operation –Continuous.
WARNING! An open internal fuse indicates a catastrophic failure of circuit component(s). Repair must be by authorized IPD personnel only.
RISK OF FIRE! Refer to fuse rating on power supply circuit board for rating.
WARNING! Dangerous voltages are present on some components, printed circuit board traces and heatsinks.
SHOCK HAZARD!
INPUT FUSE: This product includes a single fuse in the phase lead only. In consideration of IEC 60601-1:2005 Clause 8.11.5, a second fuse may
be required in the neutral lead of the end use equipment
SEPERATION: Primary to secondary creepage distance is 8mm minimum, clearance 5mm minimum (2MOPP). Primary to ground creepage
distance is 4mm minimum, clearance 2.5mm minimum (1MOPP). Secondary to ground creepage is 2.3mm minimum, clearance is
1.4mm minimum (Operational Insulation). Required seperation must be maintained in the end use equipment to preserve the
established means of protection.
OUTPUTS: The outputs are not acceptable for patient connection without additional isolation. All outputs are ES1 under normal and single
fault conditions unless otherwise indicated.
TEMPERATURES: The maximum operating temperatures of safety components as defined in the applicable safety standards must not be exceeded
after installation in the end use equipment. Output power, ambient air temperature and convection or forced air cooling availability
should be considered in the end use equipment.
HIPOT: In consideration of IEC 60601-1:2005 Clause 8.8.3, care must be taken to insure the voltage applied to a reinforced insulation does
not overstress different types and levels of insulation. Breakdown of basic insulation and catastrophic failure of the power supply
may result if a test voltage of greater than 1800 VAC is applied between primary and secondary circuits. Each isolating component
is factory tested at 4000 VAC minimum prior to installation. Primary and secondary to ground capacitors may need to be
disconnected prior to performing a dielectric strength test on the power supply or the end product.
INSTALLATION: The power supplies included in model listing on reverse side are considered components intended for professional installation into
end use equipment. The protective earth (ground) terminal must be bonded to protective earth in the end use equipment.
EMISSIONS: This product was tested for compliance with EN 55022 and EN 55011 Class B conducted and radiated emissions using the
techniques listed below and non-inductive load resistors to simulate operation in a typical installation. All or a combination of the
following requirements may be necessary to insure compliance in the end use equipment.
1. Installation of the power supply, output cables and loads in a shielded enclosure.
2. Use of optional chassis and cover.
3. Use of shielded I/O cables.
4. Use of ferrite beads on I/O cables.
5. Grounded output returns.
CONNECTIONS /
DIMENSIONS:
AIR FLOW 1. Recommended 2. Good 3. Fair
DIRECTION:
CONNECTORS: P1: AC Input –0.156 inch friction lock header mates with Molex 09-50-3031 or equivalent crimp terminal housing with Molex
2478 or equivalent crimp terminal.
P2: DC Output (Single Output) –6-32 screw-down terminal mates with #6 ring-tongue terminal (10 in.-lb. max.).
P2: DC Output (Multiple Output) –0.156 inch friction lock header mates with Molex 09-50-3161 or equivalent crimp terminal
housing with Molex 2478 or equivalent crimp terminal.
G: Protective Earth (Ground) –0.187 quick disconnect terminal.
P3: Option / Sense (Single Output) –0.100 friction lock header mates with Molex 50-57-9008 or equivalent crimp terminal
housing with Molex type 71851 or equivalent crimp terminal.
P3: Option / Sense (Multiple Output) - 0.100 breakaway header mates with Molex 22-55-2081 or equivalent crimp terminal
housing with Molex type 71851 or equivalent crimp terminal.
This manual suits for next models
28
Other Integrated Power Designs Power Supply manuals
Popular Power Supply manuals by other brands

Videx
Videx 520MR Installation instruction

Poppstar
Poppstar 1008821 Instructions for use

TDK-Lambda
TDK-Lambda LZS-A1000-3 Installation, operation and maintenance manual

TDK-Lambda
TDK-Lambda 500A instruction manual

Calira
Calira EVS 17/07-DS/IU operating instructions

Monacor
Monacor PS-12CCD instruction manual