Intel S2600CO Family Configuration guide

Intel®Server Board S2600CO Family
Technical Product Specification
Intel order number G42278-002
Revision 1.0
February, 2012
Enterprise Platforms and Services Division –Marketing

Revision History Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
ii
Revision History
Date
Revision
Number
Modifications
February, 2012
1.0
Initial release.
Disclaimers
Information in this document is provided in connection with Intel®products. No license, express or implied, by
estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's
Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any
express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to
fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property
right. Intel products are not intended for use in medical, lifesaving, or life sustaining applications. Intel®may make
changes to specifications and product descriptions at any time without notice. Designers must not rely on the
absence or characteristics of any features or instructions marked "reserved" or "undefined." Intel®reserves these for
future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future
changes to them.
The products described in this document may contain design defects or errors known as errata which may cause the
product to deviate from published specifications. Current characterized errata are available on request.
This document and the software described in it are furnished under license and may only be used or copied in
accordance with the terms of the license. The information in this manual is furnished for informational use only, is
subject to change without notice, and should not be construed as a commitment by Intel Corporation. Intel
Corporation assumes no responsibility or liability for any errors or inaccuracies that may appear in this document or
any software that may be provided in association with this document.
Except as permitted by such license, no part of this document may be reproduced, stored in a retrieval system, or
transmitted in any form or by any means without the express written consent of Intel Corporation.
Contact your local Intel®sales office or your distributor to obtain the latest specifications before placing your product
order.
Intel, Pentium, Itanium, and Xeon are trademarks or registered trademarks of Intel Corporation.
*Other brands and names may be claimed as the property of others.
Copyright © 2012 Intel Corporation

Intel® Server Board S2600CO Family TPS Table of Contents
Revision 1.0
Intel order number G42278-002
iii
Table of Contents
1. Introduction ..........................................................................................................................1
1.1 Chapter Outline........................................................................................................1
1.2 Server Board Use Disclaimer ..................................................................................1
2. Product Overview.................................................................................................................3
2.1 Server Board Connector and Component Layout....................................................5
2.2 Server Board Dimensional Mechanical Drawings..................................................10
3. Functional Architecture Overview....................................................................................15
3.1 Processor Support.................................................................................................16
3.1.1 Processor Socket Assembly ..................................................................................16
3.1.2 Processor Population Rules ..................................................................................16
3.1.3 Processor Initializion Error Summary ....................................................................17
3.2 Processor Function Overview................................................................................19
3.2.1 Intel®QuickPath Interconnect................................................................................20
3.2.2 Integrated Memory Controller (IMC) and Memory Subsystem ..............................21
3.2.3 Processor Integrated I/O Module (IIO)...................................................................30
3.3 Intel®C600-A Chipset Functional Overview ..........................................................34
3.3.1 Low Pin Count (LPC) Interface ..............................................................................34
3.3.2 Universal Serial Bus (USB) Controller ...................................................................35
3.3.3 On-board Serial Attached SCSI (SAS)/Serial ATA (SATA)/RAID Support and
Options 35
3.3.4 Manageability.........................................................................................................37
3.4 Integrated Baseboard Management Controller Overview......................................38
3.4.1 Super I/O Controller...............................................................................................39
3.4.2 Graphics Controller and Video Support .................................................................40
3.4.3 Baseboard Management Controller.......................................................................41
4. Technology Support ..........................................................................................................43
4.1 Intel®Trusted Execution Technology.....................................................................43
4.2 Intel®Virtualization Technology –Intel®VT-x/VT-d/VT-c.......................................43
4.3 Intel®Intelligent Power Node Manager..................................................................44
4.3.1 Hardware Requirements........................................................................................45
5. System Security .................................................................................................................46
5.1 BIOS Password Protection ....................................................................................46
5.2 Trusted Platform Module (TPM) Support...............................................................47
5.2.1 TPM security BIOS ................................................................................................47
5.2.2 Physical Presence .................................................................................................48
5.2.3 TPM Security Setup Options .................................................................................48
5.3 Intel®Trusted Execution Technology.....................................................................50
6. Platform Management Functional Overview....................................................................52
6.1 Baseboard Management Controller (BMC) Firmware Feature Support.................52

Table of Contents Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
iv
6.1.1 IPMI 2.0 Features ..................................................................................................52
6.1.2 Non IPMI Features.................................................................................................53
6.1.3 New Manageability Features .................................................................................54
6.2 Advanced Configuration and Power Interface (ACPI) ...........................................56
6.3 Power Control Sources..........................................................................................56
6.4 BMC Watchdog......................................................................................................57
6.5 Fault Resilient Booting (FRB) ................................................................................57
6.6 Sensor Monitoring..................................................................................................58
6.7 Field Replaceable Unit (FRU) Inventory Device ....................................................58
6.8 System Event Log (SEL) .......................................................................................59
6.9 System Fan Management......................................................................................59
6.9.1 Thermal and Acoustic Management......................................................................59
6.9.2 Fan Profiles............................................................................................................60
6.9.3 Thermal Sensor Input to Fan Speed Control .........................................................60
6.9.4 Memory Thermal Throttling....................................................................................62
6.10 Messaging Interfaces.............................................................................................62
6.10.1 User Model ............................................................................................................63
6.10.2 IPMB Communication Interface .............................................................................63
6.10.3 LAN interface.........................................................................................................64
6.10.4 Address Resoluton Protocol (ARP) .......................................................................70
6.10.5 Internet Control Message Protocol (ICMP)............................................................70
6.10.6 Virtual Local Area Network (VLAN) .......................................................................70
6.10.7 Secure Shell (SSH)................................................................................................71
6.10.8 Serial-over-LAN (SOL 2.0).....................................................................................71
6.10.9 Platform Event Filter ..............................................................................................71
6.10.10 LAN Alterting..........................................................................................................72
6.10.11 Altert Policy Table..................................................................................................72
6.10.12 SM-CLP (SM-CLP Lite) .........................................................................................73
6.10.13 Embeded Web Server ...........................................................................................73
6.10.14 Virtual Front Panel .................................................................................................75
6.10.15 Embedded Platform Debug ...................................................................................75
6.10.16 Data Center Management Interface (DCMI)..........................................................78
6.10.17 Lightweight Directory Authentication Protocol (LDAP) ..........................................78
7. Advanced Management Features Support (RMM4).........................................................79
7.1 Keyboard, Video, and Mouse (KVM) Redirection ..................................................79
7.1.1Remote Console....................................................................................................80
7.1.2 Performance ..........................................................................................................80
7.1.3 Security..................................................................................................................81
7.1.4 Availability..............................................................................................................81
7.1.5 Usage ....................................................................................................................81
7.1.6 Force-enter BIOS Setup ........................................................................................81

Intel® Server Board S2600CO Family TPS Table of Contents
Revision 1.0
Intel order number G42278-002
v
7.2 Media Redirection..................................................................................................81
7.2.1 Availability..............................................................................................................82
7.2.2 Network Port Usage...............................................................................................82
8. On-board Connector/Header Overview............................................................................83
8.1 Power Connectors .................................................................................................83
8.1.1 Main Power............................................................................................................83
8.1.2 CPU Power Connectors.........................................................................................83
8.1.3 PCIe Card Power Connectors ...............................................................................84
8.2 Front Panel Headers and Connectors ...................................................................84
8.2.1 SSI Front Panel Header.........................................................................................84
8.2.2 Front Panel USB Connector ..................................................................................88
8.2.3 Intel Local Control Panel Connector ......................................................................88
8.3 On-Board Storage Connectors ..............................................................................88
8.3.1 SATA Only Connectors: 6 Gbps............................................................................88
8.3.2 SATA/SAS Connectors..........................................................................................89
8.3.3 SAS SGPIO Connectors........................................................................................89
8.3.4 Intel®RAID C600 Upgrade Key Connector............................................................89
8.3.5 HSBP_I2C Header.................................................................................................89
8.3.6 HDD LED Header ..................................................................................................90
8.3.7 Internal Type-A USB Connector ............................................................................90
8.3.8 Internal 2mm Low Profile eUSB SSD Connector...................................................90
8.4 Management and Security Connectors .................................................................90
8.4.1 RMM4_Lite Connector...........................................................................................90
8.4.2 RMM4_NIC connector ...........................................................................................91
8.4.3 TPM Connector......................................................................................................91
8.4.4 PMBUS Connector ................................................................................................91
8.4.5 Chassis Intrustion Header .....................................................................................91
8.4.6 IPMB Connector ....................................................................................................92
8.5 Fan Connectors .....................................................................................................92
8.5.1 System FAN Connectors .......................................................................................92
8.5.2 CPU FAN Connector .............................................................................................93
8.6 Serial Port Connectors...........................................................................................93
8.6.1 Serial Port A connector (DB9) ...............................................................................93
8.6.2 Serial Port B Connector .........................................................................................93
8.6.3 Video Connector....................................................................................................93
8.7 Other Connectors and Headers.............................................................................94
8.7.1 FAN BOARD_I2C Connector.................................................................................94
8.7.2 IEEE 1394b Connector..........................................................................................94
9. Reset and Recovery Jumpers...........................................................................................96
9.1 BIOS Default (a.k.a CMOS Clear) and Password Reset Usage Procedure ..........97
9.1.1 Set BIOS to default (a.k.a Clearing the CMOS).....................................................97

Table of Contents Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
vi
9.1.2 Clearing the Password...........................................................................................97
9.2 Integrated BMC Force Update Procedure .............................................................98
9.3 ME Force Update Jumper......................................................................................98
9.4 BIOS Recovery Jumper .........................................................................................99
10. Light Guided Diagnostics................................................................................................100
10.1 5-volt Stand-by LED.............................................................................................100
10.2 Fan Fault LEDs....................................................................................................100
10.3 DIMM Fault LEDs ................................................................................................102
10.4 System ID LED, System Status LED and POST Code Diagnostic LEDs ............102
10.4.1 System ID LED ....................................................................................................103
10.4.2 System Status LED..............................................................................................104
10.4.3 POST Code Diagnostic LEDs..............................................................................104
11. Environmental Limits Specification ...............................................................................106
11.1 Processor Thermal Design Power (TDP) Support...............................................106
11.2 MTBF...................................................................................................................106
12. Power Supply Specification Guidelines.........................................................................108
12.1 Power Supply DC Output Specification ...............................................................108
12.1.1 Output Power/Currents........................................................................................108
12.1.2 Cross Loading......................................................................................................108
12.1.3 Standby Output....................................................................................................109
Appendix A: Integration and Usage Tips..............................................................................114
Appendix B: Compatiable Intel®Server Chassis .................................................................115
Appendix C: Integrated BMC Sensor Tables........................................................................122
Appendix D: Intel®Server Board S2600CO Family Specific Sensors................................135
Product ID ..........................................................................................................................135
ACPI S3 Sleep State Support ............................................................................................135
Processor Support for Intel®Server Board S2600CO........................................................135
Supported Chassis.............................................................................................................135
Hot-plug fan support...........................................................................................................136
Fan redundancy support ....................................................................................................136
HSC Availability..................................................................................................................138
Power unit support .............................................................................................................138
Redundant Fans only for Intel®Server Chassis .................................................................139
Fan Fault LED support .......................................................................................................139
Memory Throttling support .................................................................................................139
Appendix E: Management Engine Generated SEL Event Messages .................................140
Appendix F: POST Code Diagnostic LED Decoder..............................................................142
Appendix G: POST Code Errors............................................................................................147
Glossary...................................................................................................................................154
Reference Documents............................................................................................................157

Intel® Server Board S2600CO Family TPS List of Figures
Revision 1.0
Intel order number G42278-002
vii
List of Figures
Figure 1. Major Board Components..............................................................................................6
Figure 2. Intel®Light Guided Diagnostic LED Identification..........................................................7
Figure 3. Jumper Block Identification............................................................................................8
Figure 4. Rear I/O Layout .............................................................................................................9
Figure 5. Mounting Hole Locations (1 of 2).................................................................................10
Figure 6. Mounting Hole Locations (2 of 2).................................................................................11
Figure 7. Major Connector Pin-1 Locations ................................................................................12
Figure 8. Primary Side Keep-out.................................................................................................13
Figure 9. Secondary Side Keep-out............................................................................................14
Figure 10. Intel®Server Board S2600CO Functional Block Diagram .........................................15
Figure 11. Processor Socket Assembly......................................................................................16
Figure 12. Integrated Memory Controller Functional Block Diagram ..........................................21
Figure 13. Intel®Server Board S2600CO DIMM Slot Layout......................................................24
Figure 14. Functional Block Diagram of Processor IIO Sub-system...........................................31
Figure 15. Functional Block Diagram - Chipset Supported Features and Functions ..................34
Figure 16. Intel®RAID C600 Upgrade Key Connector................................................................35
Figure 17. Integrated BMC Functional Block Diagram................................................................38
Figure 18. Integrated BMC Hardware.........................................................................................39
Figure 19. Setup Utility –TPM Configuration Screen .................................................................49
Figure 20. High Level Fan Speed Control Structure ...................................................................61
Figure 21. Server Board Jumper Block Locations (J1E2, J1E3, J1E4, J1E6, J2J2)...................96
Figure 22. 5-volt Stand-by Status LED Location.......................................................................100
Figure 23. Fan Fault LED’s Location ........................................................................................101
Figure 24. DIMM Fault LED’s Location .....................................................................................102
Figure 25. Location of System Status, System ID and POST Code Diagnostic LEDs..............103
Figure 26. Differential Noise test setup.....................................................................................111
Figure 27. Output Voltage Timing .............................................................................................112
Figure 28. Turn On/Off Timing (Power Supply Signals)............................................................113
Figure 29. Intel®Server Chassis P4308XXMFEN.....................................................................115
Figure 30. Intel®Server Chassis P4308XXMHGC....................................................................116
Figure 31. Chassis/System Product Code Naming Conventions..............................................117

List of Tables Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
viii
List of Tables
Table 1. Intel®Server Board S2600CO Family Feature Set .........................................................3
Table 2. Mixed Processor Configurations Error Summary..........................................................18
Table 3. UDIMM Support Guidelines ..........................................................................................22
Table 4. RDIMM Support Guidelines ..........................................................................................22
Table 5. LRDIMM Support Guidelines ........................................................................................23
Table 6. Intel®Server Board S2600CO DIMM Nomenclature.....................................................24
Table 7. Supported Intel®Integrated RAID Modules...................................................................32
Table 8. Supported Intel®Riser Card..........................................................................................33
Table 9. External RJ45 NIC Port LED Definition.........................................................................33
Table 10. Intel®RAID C600 Upgrade Key Options.....................................................................36
Table 11. Video Modes...............................................................................................................40
Table 12. Video mode.................................................................................................................41
Table 13. Data Center Problems ................................................................................................44
Table 14. Setup Utility –Security Configuration Screen Fields ..................................................50
Table 15. ACPI Power States .....................................................................................................56
Table 16. Power Control Initiators...............................................................................................56
Table 17. Fan Profile Mapping....................................................................................................60
Table 18. Standard ID Channel Assignments.............................................................................63
Table 19. Factory Configured PEF Table Entries .......................................................................71
Table 20. Diagnostic Data...........................................................................................................77
Table 21. Additional Diagnostics on Error...................................................................................77
Table 22. Intel®RMM4 options kits.............................................................................................79
Table 23. Enabling Advanced Management Features................................................................79
Table 24. Main Power Connector Pin-out (“MAIN PWR”) ...........................................................83
Table 25. CPU Power Connector Pin-out (“CPU_1 PWR” and “CPU_2 PWR”) .........................83
Table 26. PCIe Card Power Connector Pin-out (“OPT_12V_PWR”) ..........................................84
Table 27. SSI Front Panel Header Pin-out (“SSI Front Panel”) ..................................................84
Table 28. Power/Sleep LED Functional States...........................................................................85
Table 29. NMI Signal Generation and Event Logging.................................................................86
Table 30. System Status LED State Definitions..........................................................................86
Table 31. Front Panel USB Connector Pin-out (USB5-6) ...........................................................88
Table 32. Intel Local Control Pane Connector Pin-out (LCP) .....................................................88
Table 33. SATA Only Connector Pin-out (SATA_0 and SATA_1) ..............................................88
Table 34. SATA/SAS Connector Pin-out (SATA/SAS_0 to SATA/SAS_7).................................89
Table 35. SAS SGPIO Connector Pin-out (SAS_SPGIO_0 and SAS_SPGIO_1)......................89
Table 36. Intel®RAID C600 Upgrade Key Connector Pin-out (STRO UPG KEY)......................89
Table 37. HSBP_I2C Header Pin-out (HSBP_I2C).....................................................................89
Table 38. Hard Drive Acitivity Header Pin-out (HDD_LED) ........................................................90
Table 39. Internal Type-A USB2.0 Connector Pin-out (USB_4) .................................................90

Intel® Server Board S2600CO Family TPS List of Tables
Revision 1.0
Intel order number G42278-002
ix
Table 40. Internal eUSB Connector Pin-out (eUSB_SSD) .........................................................90
Table 41. RMM4_Lite Connector Pin-out (RMM4_Lite)..............................................................91
Table 42. RMM4_NIC Connector Pin-out (RMM4_NIC) .............................................................91
Table 43. TPM Connector Pin-out (TPM) ...................................................................................91
Table 44. PMBUS Connector Pin-out (SMB_PMBUS) ...............................................................91
Table 45. Chassis Intrusion Header Pin-out (CHAS INTR) ........................................................92
Table 46. Chassis Instrusion Header State Description .............................................................92
Table 47. IPMB Connector Pin-out (IPMB).................................................................................92
Table 48. 6-pin System FAN Connector Pin-out (SYS_FAN_1 to SYS_FAN_6)........................92
Table 49. 4-pin System FAN Connector Pin-out (SYS_FAN_7) .................................................92
Table 50. CPU Fan Connector Pin-out (CPU_1 FAN and CPU_2 FAN) ....................................93
Table 51. Serial Port A Connector Pin-out (SERIAL_A) .............................................................93
Table 52. Serial-B Connector Pin-out (SERIAL_B).....................................................................93
Table 53. Rear VGA Video Connector Pinout (VGA)..................................................................93
Table 54. HSBP 4-PIN I2C BUS Connector pin out(FAN BOARD_I2C).....................................94
Table 55. IEEE 1394b Connector pin out ...................................................................................95
Table 56. Server Board Jumpers (J1E2, J1E3, J1E4, J1E6, J1J2) ............................................96
Table 57. System Status LED...................................................................................................104
Table 58. POST Code Diagnostic LEDs...................................................................................105
Table 59. Server Board Design Specifications .........................................................................106
Table 60. MTBF Estimate .........................................................................................................107
Table 61. Over Voltage Protection Limits .................................................................................108
Table 62. Loading Conditions ...................................................................................................108
Table 63. Voltage Regulation Limits .........................................................................................109
Table 64. Transient Load Requirements...................................................................................109
Table 65. Capacitive Loading Conditions .................................................................................110
Table 66. Ripples and Noise.....................................................................................................110
Table 67. Output Voltage Timing ..............................................................................................111
Table 68. Turn On/Off Timing ...................................................................................................112
Table 69. Intel®Server Chassis P4000M family Features ........................................................118
Table 70. BMC Core Sensors ...................................................................................................124
Table 71. Chassis-specific Sensors..........................................................................................135
Table 72. Fan Domain Definition ..............................................................................................136
Table 73. Power Supply Support ..............................................................................................138
Table 74. Server Platform Services Firmware Health Event.....................................................140
Table 75. Node Manager Health Event.....................................................................................141
Table 76. POST Progress Code LED Example ........................................................................142
Table 77. Diagnostic LED POST Code Decoder ......................................................................143
Table 78. MRC Progress Codes ...............................................................................................145
Table 79. MRC Fatal Error Codes ............................................................................................145
Table 80. POST Error Codes and Messages ...........................................................................147

List of Tables Intel® Server Board S2600CO Family TPS
Revision 1.0
Intel order number G42278-002
x
Table 81. POST Error Beep Codes ..........................................................................................152
Table 82. Integrated BMC Beep Codes....................................................................................153

Intel® Server Board S2600CO Family TPS List of Tables
Revision 1.0
Intel order number G42278-002
xi
<This page is intentionally left blank.>

Intel® Server Board S2600CO Family TPS Introduction
Revision 1.0 1
Intel order number G42278-002
1. Introduction
This Technical Product Specification (TPS) provides board-specific information detailing the
features, functionality, and high-level architecture of the Intel®Server Board S2600CO.
Design-level information related to specific server board components and subsystems can be
obtained by ordering External Product Specifications (EPS) or External Design Specifications
(EDS) related to this server generation. EPS and EDS documents are made available under
NDA with Intel and must be ordered through your local Intel® representative. See the Reference
Documents section for a list of available documents.
1.1 Chapter Outline
This document is divided into the following chapters:
Chapter 1 –Introduction
Chapter 2 –Product Overview
Chapter 3 –Functional Architecture Overview
Chapter 4 –Technology Support
Chapter 5 –System Security
Chapter 6 –Platform Management Functional Overview
Chapter 7 –Advanced Management Feature Support (RMM4)
Chapter 8 –On-board Connector/Header Overview
Chapter 9 –Reset and Recovery Jumpers
Chapter 10 –Light Guided Diagnostics
Chapter 11 –Environmental Limits Specifications
Chapter 12 –Power Supply Specification Guidelines
Appendix A: Integration and Usage Tips
Appendix B: Compatible Intel®Server Chassis
Appendix C: Integrated BMC Sensor Tables
Appendix D: Intel®Server Board S2600CO Family Specific Sensors
Appendix E: Management Engine Generated SEL Event Messages
Appendix F: POST Code Diagnostic LED Decoder
Appendix G: POST Code Errors
Glossary
Reference Documents
1.2 Server Board Use Disclaimer
Intel Corporation server boards support add-in peripherals and contain a number of high-density
VLSI (Very-large-scale integration) and power delivery components that need adequate airflow
to cool. Intel ensures through its own chassis development and testing that when Intel®server
building blocks are used together, the fully integrated system will meet the intended thermal
requirements of these components. It is the responsibility of the system integrator who chooses
not to use Intel developed server building blocks to consult vendor datasheets and operating
parameters to determine the amount of airflow required for their specific application and

Introduction Intel® Server Board S2600CO Family TPS
2 Revision 1.0
Intel order number G42278-002
environmental conditions. Intel Corporation cannot be held responsible if components fail or the
server board does not operate correctly when used outside any of the published operating or
non-operating limits.

Intel® Server Board S2600CO Family TPS Product Overview
Revision 1.0 3
Intel order number G42278-002
2. Product Overview
The Intel®Server Board S2600CO is a monolithic printed circuit board (PCB) assembly with
features designed to support the pedestal server markets. It has two board SKUs, namely
S2600CO4 and S2600COE. These server boards are designed to support the Intel®Xeon®
Processor E5-2600 product family. Previous generation Intel®Xeon®processors are not
supported. Many of the features and functions of these two SKUs are common. A board will be
identified by name when a described feature or function is unique to it.
Table 1. Intel®Server Board S2600CO Family Feature Set
Feature
Description
Processor Support
Two LGA 2011 (Socket R) processor sockets
S2600CO4 - Support for one or two Intel®Xeon®Processor(s) E5-2600 product with
a Thermal Design Power (TDP) of up to 135W.
S2600COE - Support for one or two Intel®Xeon®Processor(s) E5-2600 product
family with a Thermal Design Power (TDP) of up to 150W with possible
configuration limits.
Memory
16 DIMM slots –2 DIMM slots/channel –4 memory channels per processor
Channels A, B, C, D, E, F, G and H
Support for Registered DDR3 Memory (RDIMM), LV-RDIMM, Unbuffered DDR3
memory ((UDIMM) with ECC and Load Reduced DDR3 memory (LR-DIMM)
Memory DDR3 data transfer rate of 800, 1066, and 1333 MT/s and1600 MT/s
DDR3 standard I/O voltage of 1.5V and DDR3 Low Voltage of 1.35V
Chipset
Intel® C600-A chipset with support for optional Storage Option Select keys
Rear I/O connections
One DB15 Video VGA connector
One DB9 Serial connector
Four USB2.0 connectors
Four RJ-45 Network Interface Connectors supporting 10/100/1000Mb
Internal I/O
connectors/headers
One 2x5 pin connector providing front panel support for two USB ports
One internal type A USB 2.0 connector
One internal low-profile 2mm USB port for USB Solid State Drive
One 2x15 pin SSI-EEB compliant front panel connector
One DH-10 Serial Port B connector
Two internal IEEE 1394b connectors (Intel®Server Board S2600COE only.)
Cooling Fan Support
Two 4-pin managed CPU fan headers
Six 6-pin managed system fan headers
One 4-pin managed rear system fan header
One 4-pin I2C header that is intended to be used for third party fan control circuits
using a Maxim 72408 controller. (Intel®Server Board S2600CO4 only.)

Product Overview Intel® Server Board S2600CO Family TPS
4 Revision 1.0
Intel order number G42278-002
Feature
Description
Add-in Card Slots
Support up to six expansion slots
Slot 1: PCIe Gen II x4 electrical with x8 physical connector, routed from Intel®C600
Chipset, support half-length card
Slot 2: PCIe Gen III x16 electrical with x16 physical connector, routed from CPU1,
support full length card
Slot 3: PCIe Gen III x16 electrical with x16 physical connector, routed from CPU2,
support full length, double width card
Slot 4: PCIe Gen III x8 electrical with x8 connector, routed from CPU2, support full
length card; support Intel designed SAS RAID on Card (ROC) Module (PCIe slot
form factor)
Slot 5: PCIe Gen III x16 electrical with x16 connector, routed from CPU1, support
full length, double width card
Slot 6: PCIe Gen III x16 electrical with x16 connector, routed from CPU2, support
half-length card, Intel designed PCIe riser card
Storage
One low-profile eUSB 2x5 pin connector to support 2mm low-profile eUSB solid
state devices
Two AHCI SATA connectors capable of supporting up to 6Gb/sec
AHCI SATA 0 supports high profile, vertical SATA DOM with onboard power.
Eight SCU SAS/SATA connectors capable of supporting up to 3Gb/sec
Intel SAS ROC module support (Optional, PCIe slot form factor)
Intel®RAID C600 Upgrade Key support providing optional expanded SAS/SATA
RAID capabilities
RAID Support
Intel®RSTe SW RAID 0/1/10/5
LSI SW RAID 0/1/10
Video Support
Integrated Matrox G200 2D Video Graphics controller
LAN
Four Gigabit through Intel®I350-AM Quad 10/100/1000 integrated GbE MAC and PHY
controller
Security
Trusted Platform Module (Accessory Option)
Server Management
Integrated Baseboard Management Controller, IPMI 2.0 compliant
Support for Intel®Server Management Software
Intel®Remote Management Module 4 support (Accessory Option)
Intel®Remote Management Module 4 Lite support (Accessory Option)
Form Factor
SSI EEB (12”x13”)
Compatible Intel®Server
Chassis
Intel®Server Chassis P4000M family

Intel® Server Board S2600CO Family TPS Product Overview
Revision 1.0 5
Intel order number G42278-002
2.1 Server Board Connector and Component Layout
The following illustrations provide a general overview of the server board, identifying key feature
and component locations. Each connector and major component is identified by a number or
letter, and the description is given below the figure.
Callout
Description
Callout
Description
A
Chassis Intrusion
AH
System Fan 1 Connector
B
Slot1, PCI Express* Gen2
AI
LCP
C
RMM4 Lite
AJ
Optional 12V Power Connector
D
Slot 2, PCI Express* Gen3
AK
BIOS Default
E
Slot 3, PCI Express* Gen3
AL
SMB_PMBUS

Product Overview Intel® Server Board S2600CO Family TPS
6 Revision 1.0
Intel order number G42278-002
Callout
Description
Callout
Description
F
Battery
AM
Main Power
G
Slot 4, PCI Express* Gen3
AN
USB_4 (Internal Type A USB
Connector)
H
Slot 5, PCI Express* Gen3
AO
Storage Upgrade key connector
I
Slot 6, PCI Express* Gen3
AP*
FAN BOARD_I2C (Intel®Server
Board S2600CO4 only)
J
DIMM E1/E2/F1/F2
AQ
SATA_0 connector
K
Status LED
AR
SATA_1 Connector
L
ID LED
AS
SAS/SATA_7 Connector
M
Diagnostic LED
AT
SAS/SATA_6 Connector
N
NIC 3/4
AU
SAS/SATA_5 Connector
O
USB 0/1/2/3, NIC 1,2
AV
SAS/SATA_4 Connector
P
VGA
AW
SAS/SATA_3 Connector
Q
CPU 2 Power connector
AX
SAS/SATA_2 Connector
R
System Fan 7
AY
SAS/SATA_1 Connector
S
Serial Port A
AZ
SAS/SATA_0 Connector
T
CPU 2 Fan Connector
BA
SAS SGPIO 0
U
DIMM H1/H2/G1/G2
BB
SAS SGPIO 1
V
DIMM A1/A2/B1/B2
BC
IPMB
W
CPU 1 Power connector
BD
HSBP_I2C
X
CPU 1 Fan Connector
BE
USB 5-6 (front panel USB connector)
Y
DIMM C1/C2/D1/D2
BF
ME Force Update
Z
USB port to support SSD
BG
BMC Force Update
AA
HDD LED Header
BH**
IEEE_1394B_0 Connector (Intel®
Server Board S2600COE only)
AB
TPM Connector
BI
Password Clear
AC
System Fan 6 Connector
BJ
BIOS Recovery
AD
System Fan 5 Connector
BK**
IEEE_1394B_1 Connector (Intel®
Server Board S2600COE only)
AE
System Fan 4 Connector
BL
Serial B connector
AF
System Fan 3 Connector
BM
RMM4 NIC
AG
System Fan 2 Connector
BN
SSI Front Panel
Figure 1. Major Board Components

Intel® Server Board S2600CO Family TPS Product Overview
Revision 1.0 9
Intel order number G42278-002
Callout
Description
Callout
Description
A
Serial Port A
E
NIC Port 3 and 4
B
Video
F
Diagnostics LED’s
C
NIC Port 1, USB Port 0 (top) and 1
(bottom)
G
ID LED
D
NIC Port 2, USB Port 2 (top) and 3
(bottom)
H
Status LED
Figure 4. Rear I/O Layout
This manual suits for next models
1
Table of contents
Other Intel Server Board manuals

Intel
Intel S5000PAL User manual

Intel
Intel SE7500CW2 Configuration guide

Intel
Intel S2600CO series User manual

Intel
Intel SE7525RP2 User manual

Intel
Intel S3200SH Installation guide

Intel
Intel S5500BC Setup guide

Intel
Intel S3000AH User manual

Intel
Intel SE7230NH1-E User manual

Intel
Intel SE7221BK1 User manual

Intel
Intel S5000VCL - Server Board Motherboard Configuration guide