Congratulations, you have just purchased a product with Intelbras quality and safety.
The XAS 8000 opening sensor is indicated for protecting doors and windows, monitoring their opening and closing. Easy
installation product, it has a low consumption circuit, providing a longer battery life. It also has a tamper key for tamper
protection, making your environment even more secure, a key for registration and a status indicator LED. These features set
the XAS 8000 aperture sensor apart from other wireless aperture sensors on the market. Carefully read the introductory
product information for the correct use of the sensor.

Care and safety
» LGPD – Data processing by Intelbras: Intelbras does not access, transfer, capture or perform any type of processing of
personal data from this product.
» This product is intended for indoor environments.
» Respect the distance of the GAP (distance between the sensor is the magnet).
» Conrm the installation location is stable and appropriate.
» Wireless communication technology, when exposed to environments with high power radiation, may suffer interference
and have its performance impaired, for example: places close to TV towers, AM/FM radio station, amateur radio station,
etc.
» Do not expose the XAS 8000 magnetic sensor to direct sunlight, rain and moisture.
» Avoid installing the sensor directly under metal surfaces so that there are no changes in its operating characteristics.
» For your safety, test the product and systems at least once a week. This is necessary due to changing environmental
conditions, electrical or electronic outages and violations. Take all necessary precautions for the safety and protection
of your property.

Summary
1. Technical specications 5
2. Features 5
3. Product 6
4. Sensor opening 6
5. Enrolling the XAS 8000 sensor 7
5.1. Deleting sensor registration ...................................................................7
6. Identied the best location for installation 8
7. Installation 8
8. Conguring the XAS 8000 sensor 10
8.1. Conguring the sensor via the keyboard.........................................................10
8.2. Information about LED operation ..............................................................10
9. Battery 12
10. Test 12
11. Homologation 12
Warranty term 13

5
1. Technical specications
Operating voltage 3V Lithium battery, model CR2450
Operating current 3uA
RF range 1000 meters without barrier
Transmission frequency 915 MHz – 928 MHz
Power 11 dBm
Modulation DSSSS BPSK 40 Kbps
Compatibility AMT 8000 alarm panel
Anti jamming Against invasive signs
Anti-violation Rear tamper
Installation environment Internal
Maximum GAP 20 mm ± 15%
Operating Temperature -10 °C to 50 °C
Sensor Dimensions (W × H × D) 34,4 × 18,6 × 69,2 mm
Magnet Dimensions (W × H × D) 22,5 × 18,3 × 69,2 mm
2. Features
» Anti-tamper (tamper key);
» Low battery indication;
» Easy installation;
» Key for registration;
» Drive status indication LED;
» Protection against malicious signals;
» Encryption in the transmission of data between devices;
» Transmission frequency 915 MHz – 928 MHz;
» Wireless communication with range of up to 1000 meters with direct sight in open eld.

6
3. Product
1. Sensor base
2. Screw hole for xing
3. Button for registration
4. Light conductor (LED)
5. Sensor cover
6. Magnet cover
7. Battery contact
8. Sync key
9. Tamper key
10. Magnet base
4. Sensor opening
To access the XAS 8000 board for registration, battery replacement or to unregister it from the control unit, simply open
the lock with the help of a screwdriver and remove its base. This way the board will be exposed and ready for handling.
Magnet Sensor

7
Remove the plate, then insert the battery (model CR2450), respecting the polarity.
5. Enrolling the XAS 8000 sensor
The sensor registration can be performed through the AMT 8000 Desktop Programmer software, remote AMT mobile
application, keyboard commands and synchronization button on the alarm center.
Follow the procedure below for registration through the synchronization button on the control panel.
In this type of registration, the address of the sensors follows the registration sequence, Example: First sensor will be
registered in zone 1, the second sensor in zone 2 and so on. For other forms of registration, please consult the complete
manual of the AMT 8000 control panel.
1. Press the alarm control panel synchronization button;
2. LED 3 on the control unit stays on for 3 minutes, indicating that it is waiting for the sensor to register;
3. Insert the battery into the sensor;
4. Press the sensor synchronization key;
5. The status LED will ash green indicating the correct registration. If it ashes red, the registration was not carried out
and the procedure must be repeated.
5.1. Deleting sensor registration
To remove the device from the control panel, two steps are necessary, one directly on the sensor and the other on the
control panel.
» Sensor: press and hold the sensor timing switch for approximately 10 seconds, watching the status LED blink red twice
slowly.
» Alarm control panel: enter the programming mode and type the command below:
01 to 64
Enter71Enter Zone N° +++
For other ways to remove the sensor from the control panel, please consult the complete manual of the AMT 8000 control
panel.

8
6. Identied the best location for installation
The XAS 8000 sensor has signal level indications for communication with the AMT 8000 control panel, this will help you
to choose the best installation location. Follow the procedure:
1. After duly registered, take the sensor to the environment you want to protect;
2. Once chosen, position the sensor in the exact place where it will be installed and carry out a transmission through an
opening and a closing, if the sensor is in a door or window for example, just open and close it.
Note: It is very important to check the LED status when opening and closing.
3. Observe a cor que o LED irá acender e verique na tabela a seguir se o sensor poderá ser instalado nesse local;
LED status Communication level
Green Excellent signal level (recommended installation location)
Orange Regular signal level Not recommended location for installation (communication failure may occur)
Red No communication (Do not install on site)
4. If the signal level is not excellent, reposition the sensor and perform the procedure again.
7. Installation
The XAS 8000 sensor can be secured using double-sided tape or screw. If the option with double-sided tape is chosen,
clean the surface that will be in direct contact with the tape and then glue it to the base of the product. If you are going
to use screws, just open the sensor and use the holes for the screw located on the base of the product, as shown in the
following gure.
The recommended screw for xing the product is 18×3 mm.
Screw installation
Sensor base Base magnet Base magnet
Sensor base
Reset Sync
Installation with double-sided tape
Tape

9
Important: check that the GAP distance (distance between the sensor and the magnet) is within the specied range, to
avoid unwanted triggering if any vibration occurs in the structure in which the sensor is installed.
Maximum GAP: 20 mm ±15%.
To close the sensor and the magnet, simply t the locks and then press the other side for complete closure.
Reset Sync
Press to lock
Mount the latches

10
8. Conguring the XAS 8000 sensor
The adjustment of sensor settings can be done in two ways, below we present the step by step of each one.
8.1. Conguring the sensor via the keyboard
Using the AMT 8000 control panel keypad, enter programming mode with the installer password, then enter the following
command:
000 = Off
010 = On
Zone in which the sensor
is registered from 01 to 64
LED Enter66Enter Zone + +++
8.2. Information about LED operation
» LED Off: the LED only lights up for the rst 15 minutes after inserting the battery. Factory standard.
Note:
even with the LED Off setting, a rapid blinking of the LED may be noticeable during each transmission.
» LED on: the LED lights up every time it is opened and closed.
Conguring the LED through the app
After the app is properly connected to the alarm center, select Congure center on the main screen of the app.
Menu
Congure central >
Online >
Events >
Then select sensors:
Settings
General >
Zones >
Passwords >
Communication >
Event codes >
IP monitoring >
Ethernet/Wi-Fi >
GPRS >
Scheduled activation/deactivation >
Sensors >
Table of contents
Other Intelbras Security Sensor manuals

Intelbras
Intelbras IVP 1000 PET User manual

Intelbras
Intelbras IVP 2000 SF User manual

Intelbras
Intelbras IVP 3000 PET User manual

Intelbras
Intelbras IVP 4101 PET User manual

Intelbras
Intelbras IVP 4101 PET User manual

Intelbras
Intelbras IVP 8000 EX User manual

Intelbras
Intelbras IVP 1000 PET User manual

Intelbras
Intelbras VP 5311 MW Pet User manual

Intelbras
Intelbras IVP 8000 EX User manual