intensity KJR-12B/DPBG(T)-E User manual

WIRED CONTROLLER OF
AIR CONDITIONER
MAN-O-KJR12B-0615
intensity.mx
OWNER´S MANUAL
KJR-12B/DPBG(T)-E, KJR-12B/DPBG(T)-E(H)
Please read this manual carefully before operation and keep it for future reference.

CONTENTS
1.SAFETY PRECAUTION---------------------------------------------------1
2.SUMMARIZE
-----------------------------------------------------------------
2
3.FUNCTION SUMMARY----------------------------------------------------2
4. NAME AND FUNCTION OF INDICATORS ON THE WIRE
CONTROLLER ---------------------------------------------------------------3
5.INSTALLATION METHOD------------------------------------------------4
6.NAME AND OPERATION OF THE BUTTON ON THE WIRE
CONTROLLER ----------------------------------------------------------------5
7. USING METHOD ------------------------------------------------------------7
AUTOMATIC OPERATION ------------------------------------------7
COOLING/HEATING/FAN ONLY OPERATION -----------------8
DRY OPERATION -----------------------------------------------------8
TIMER SETTING-------- -----------------------------------------------8
TIMER ON AND TIMER OFF BOTH ------------------------------9
CHANGE TIMER-------------------------------------------------------9
8.TECHNICAL INDICATION AND REQUIREMENT ------------------9

NO
I
TAL
LA
TSNI
GNINRAW
Installation
commitment
Users can t install the units by themselves, or the electrical
shock or fire may be caused.
WARNING
Please entrust the dealer or the professional person to do the
installation.
!
Markers Icons
Icon s Indication
The sign shows the risk of
death or serious injury will
be caused due to the wrong
operation .
The sign shows the risk of
injury or the damage to the
property will be caused due
to the wrong operation.
Please read the safety precaution carefully before using. Do observe the following safety
precautions,for they are very important.
Before you come to the text, please be familiar with the following markers and icons, and
comply with the precautions.
WARNING
CAUTION
Followed by the detailed illustration
Followed by the detailed illustration
ENFORCE
FORBID
Indication
1. Injury means causing from the harm, burn and electrical shock , but not serious for the
hospitalization.
2. The damage of material means the disrepair of property and material.
NOTE :
Markers
NO
I
TARE
PO
NO
I
T
U
A
C
FORBID
Do not spray inflammable liquid on the Wire Controller, or
fire may be caused.
Do not operate with wet hands. Do not let water go into the
Wire Controller, or electric shock hazard may have.
SAFETY PRECAUTION
!
!
1

Usage condition:
1.Power supply:5V DC.
2.Operation temperature:-15°C(-5°F) ~ +43°C(+109°F)
3.Operation humidity:40%-90%,RH.
Main function:
1.Connecting to indoor unit by A,B,C,D,E termina.;
2.Button setting action mode.
3.LCD display.
4.Timer for rest time.
2
SUMMARIZE
FUNCTION SUMMARY
If you want to move or re-install your Wire Controller,
please contact with local dealer.
Do not disassemble your Central Controller at will. If it is
needed, please contact the local dealer.
A random disassembly may cause abnormal operation or
heating, which may result in fire.
RI
A
PE
R
DNAEVOM
NOITUAC
!
FORBID

1
O p e r a t i o n m o d e i n d i c a t i o n
3
F o l l o w m e f u n c t i o n
4
O N / O F F i n d i c a t i o n
2
T i m e r O N / O F F
7
T e m p e r a t u r e d i s p l a y z o n e
6
L o c k
5
F a n s p e e d i n d i c a t i o n
NAME AND FUCTION OF INDICATORS ON THE CONTROLLER
1.Operation mode indication:When press "MODE" button,
the following mode can be selected in circle.
Auto Cool Dry Heat Fan only Auto.
For cooling only model,heat mode is skipped.
2.Timer : When adjust setting on time or only on time is
set,the " ON " is lighted.When adjust setting off time or
only off time is set , the "OFF" is lighted. If on and off
timer are both set,the " ON " and " OFF " are both lighted.
3. Follow me function:There is a temperature sensor in-
side the wire controller, after setting temperature, the
ambient temperature induced by the temperature sen-
sor will compare with the setting temperature, and the
ambient temperature will achieve the same with the
setting temperature. It is available under cooling, heat-
ing,auto mode.
3

4.ON/OFF indication : When it is on, the icon display,
otherwise it is extinguished
5.Fan speed indication :There are four fan modes : low,
middle, high, auto.For some models,no middle fan then
the middle fan is seen as high speed.
6.Lock:When the"LOCK"button is pressed,the icon appear
and other buttons is unable, press again, the icon dis-
appear.
7.Temperature display zone : Generally it displays setting
temperature,it can be adjusted by press temperature
button and. But in fan mode,no display here.
4
INDOOR UNIT
RUN GND
+5
When a wire controller is needed, a small 5-way
terminal should be added,fix an infrared emitter with
gumwater near the receiver on the switch board.
Connect its anode and cathode to A and B,and +5V,
GND,RUN to C,D,E on the switch board.
Wire controller
5-way terminal Emitter tube
Indoor switch board
5-core shield wire
INSTALLATION METHOD

5
1.Mode botton:When press this botton,the operation mode
change as the following sequence:
Remark : For the cooling only model, the heating mode is
skipped.
2.Timer on button : Press this button, timer on function is
active. Then every press, the time increase 0.5h, after
10h, 1h increasement after each press. If cancel this
NAME AND OPERATION OF THE BUTTON ON THE WIRE CONTROLLER
AUTO
COOL
DRY
HEAT
FAN
TIMER
TEMP
RESET LOCK
MODE FAN
TURBO
DIRECT
ON/OFF BUTTON
AJUDSTMENT BUTTON
DIRECT/
HORIZONTAL SWING BUTTON
VERTICAL SWING BUTTON
LOCK BUTTON
FAN SPEED SELECTION
AJUDSTMENT BUTTON
ON
OFF
TIMER
ECO
FOLLOW
ME
SPEED
MODE BUTTON
TIMER ON BUTTON
TIMER OFF BUTTON
ECONOMY OPERATION BUTTON
FOLLOW ME BUTTON
RESET BUTTON
TURBO BUTTON

6
Function,just set it to "0.0" .
3. Timer off button: Press this button, timer off function is
active. Then every press, the time increase 0.5h, after
10h, 1h increasement after each press. If cancel this
function, just set it to "0.0" .
4 . Economy operation button:press this button,the indoor
unit operates in economy mode, press again, exit this
mode (it may be ineffective for some models)
5. Follow me button:When under cool,heat and auto mode,
press this button, follow me function is active. Press
again,this function is ineffective.
6. Turbo button :If press this button in cooling mode, the
fan speed will increase (available to some model with
powerful function). If press this button in heatmode,
electrical heater function become ineffective.
7. Reset button(hidden): Use a 1mm stick to press in the
little hole , then the current setting is canceled . The
wire controller enter into original state.
8. ON/OFF button:When in off state, press this button, the
indicator is on, the wire controller enter into on state,
and send setting information to in door Pcb . When in
on state,press this button,the indicator is off,and send
instruction.If timer on or timer off has been set,it concel
this setting then send instruction to stop the machine.
9 . Fan speed button: press this button consecutively, the
fan speed will circle as follow:

7
10. Adjust button : Set indoor temperature up. If press
and hold on, it will increase at 1°C(2°F) per 0.5 second.
11. Adjust button : Set indoor temperature down . If
press and hold on,it will decrease at 1°C(2°F) per 0.5
second.
12 .Vertical swing button: First press, start vertical swing
function;second press, stop vertical swing. (Match to
some model with vertical swing function).
13.Direct/horizontal swing button:Press the button every
time, the louver swings 6 degrees . Press and hold
for over 2 seconds ,it turns into horizontal swing mode,
press it again to quit .
14.Lock button(hidden):When you push the LOCK button,
all current settings are locked in and the wire controller
does not accept any operation except that of the LOCK
button. Use the lock mode when you want to prevent
setting from being changed accidentally or play fully.
Push the LOCK button again when you want to cancel
the LOCK mode.
Connect to power,indoor operation lamp flash.
1.Press "MODE" button, select " AUTO " ;
2.Press the button"" and " ", set temperature you want,
generally it is among 17°C(62°F) ~ 30°C(88°F)
3.Press " ON/OFF" button, operation lamp is on, the air-
conditioner work in auto mode, indoor fan is auto, and
USING METHOD
AUTOMATIC OPERATION

8
1.Press "MODE" button, select "COOL", "HEAT" or "FAN
ONLY" mode.
2.Press temperature adjust button to select setting temp.
3.Press "FAN SPEED" button to select high/mid/low/auto.
4.Press "ON/OFF" button, indoor unit operation lamp on, it
works in selected mode. Press "ON/OFF" button again,
it stops to work.
Remark:When in fan mode, no temperature can be set.
1.Press "MODE" button,select "DRY" mode.
2.Press temperature adjust button to select setting temp.
3.Press "ON/OFF" button, indoor unit operation lamp on,
it works in dry mode. Press ON/OFF button again, it stops
to work.
4.In dry mode, economy operation and fan speed are ineff-
ective.
COOL/HEAT/FAN MODE OPERATION
DRY OPERATION
can not be changed.
Auto is displayed on LCD. Press ON/OFF button again to
stop.
4.Economy operation is valid in auto mode.
TIMER SETTING
Timer on only:
1.Press "TIME ON" button, it display "SET" on LCD,and
display "H" and "ON", it is waiting for timer on setting.
2.Press "timer" on button repeatedly to adjust time setting.
3.If press this button and hold on, the time will increase at
0.5h, after 10h, it increase at 1h.
4.After setting 0.5 second, the wire controller send timer on
information, it is finished.

9
Timer off only:
1.Press "TIME OFF" button, it display "SET" on LCD,
and display "H" and ON, it is waiting for timer on setting.
2.Press "TIME OFF" button repeatedly to adjust time setting.
3.If press this button and hold on, the time will increase at
0.5h, after 10h, it increase at 1h.
4.After setting 0.5 second, the wire controller send timer off
information, it is finished.
TIMER ON AND TIMER OFF BOTH
1.Set timer on time as the corresponding step1 and 2.
2.Set timer off time as the corresponding step1 and 2.
3.Timer off time must be longer than timer on time.
4.0.5 second after setting,the wire controller send
information the setting is finished.
1.EMI and EMC comply to CE
CHANGE TIMER
If there is a need of changing timer time, press corres-
ponding button to revise it. If concel timer, change timer
time to 0.0.
Note:the timer time is relative time,that is delay after setting
time(i,e: setting time is 8:05 A,M). So when timer is set,
the standard time can not be adjusted.
TECHNICAL INDICATION AND REQUIREMENT
This manual suits for next models
1
Table of contents
Other intensity Controllers manuals
Popular Controllers manuals by other brands

Tecomotive
Tecomotive tinyCWA user manual

Toro
Toro Tempus Air RS4 user guide

Greenheck
Greenheck Microprocessor Controller reference guide

CKD
CKD ER300 instruction manual

Honeywell
Honeywell FAST-ACTING, TWO-POSITION ACTUATORS ML4202 installation instructions

Panasonic
Panasonic CZ-RD517C operating instructions