Inter-m ECS-6216MS User manual

Operation Manual
Emergency Combination System
ECS-6216MS
* Rack mount products in the Western Hemisphere(North America, South America, and the Caribbean)
do not have handles installed due to customer preference.

EMERGENCY COMBINATION SYSTEM
Welcome
Welcome
A personal welcome to you rom the management and employees o Inter-M
All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value,
and we are delighted you have purchased one of our products.
We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete
satisfaction, we will endeavor to make things right.
Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!
RI K OF ELECTRIC HOCK
DO NOT OPEN
CAUTION
CAUTION: TO REDUCE THE RI K OF ELECTRIC HOCK.
DO NOT REMOVE COVER (OR BACK).
NO U ER- ERVICEABLE PART IN IDE.
REFER ERVICING TO QUALIFIED ERVICE PER ONNEL.
WARNING
To prevent fire or shock hazard, do not
expose the unit to rain or moisture.
*WARNING FOR YOUR PROTECTION PLEA E READ THE FOLLOWING-WATER AND MOI TURE: Unit should not be used near water(e.g.
near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do
not fall and liquids are not spilled into the enclosure through openings.
*Do not install this equipment in a confined space such as a book case or similar unit.
*This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
*This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
*
It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.
*
The socket-outlet shall be installed near the equipment and shall be easily accessible.
CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing
other than that contained in the operating instructions unless you are qualified to do so.
NOTE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful
interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
This symbol is intended to alert the user to the
presence of uninsulated “dangerous voltage” within
the product’s enclosure that may be of sufficient
magnitude to constitute a risk of electric shock to
persons.
This symbol is intended to alert the user to the
presence of important operation and maintenance
(servicing) instructions in the literature accompanying
the appliance.
Caution: To prevent electric shock do not use this (polarized) plug with
an extension cord, receptacle or other outlet unless the
blades can be fully inserted to prevent blade exposure.
Attentions: Pour prévenir les chocs électriques ne pas utiliser cette
fiche polarisée avec un prolongateur, une prise de courant
on une autre sortie de courant, sauf si les lames peuvent
étre insérées à fond sans en laisser aucune partie à
découvert.

EMERGENCY COMBINATION SYSTEM
1
ECS-6216MS
Contents
Contents
Unpacking....................................................................................................................................... 2
Installation
Environment....................................................................................................................................2
Important Safety Instructions.............................................................................................................2
Features........................................................................................................................................... 3
Equipment Setup and Inspection................................................................................................. 4
Front Panel...................................................................................................................................... 5
Rear Panel....................................................................................................................................... 6
Applications.................................................................................................................................... 9
Block Diagram.............................................................................................................................. 10
Speci ications................................................................................................................................ 11
Service............................................................................................................................................12
Procedures....................................................................................................................................12
Schematic.....................................................................................................................................12
Parts List....................................................................................................................................... 12
Variations and Options............................................................................................................... 12
Warranty....................................................................................................................................... 12

EMERGENCY COMBINATION SYSTEM
2ECS-6216MS
Installation
Unpacking
Unpacking
Although your ECS-6216MS is neither complicated nor difficult to operate, we recommend you take a few
minutes to read this brief manual and familiarize yourself with the important information regarding product
features, setup and operation.
As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event
the product must be returned for servicing, the original packaging (or reasonable equivalent) is required.
Installation
Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such
environments usually include high levels of heat, dust, moisture, and vibration.
IMPORTANT SAFETY INSTRUCTIONS
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including
amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult
an electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and
the point where they exit from the apparatus.
11. Only use attachments/accessories specified by the manufacturer.
12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
13. Unplug this apparatus during lightning storms or when unused for long periods of time.
14. Refer all servicing to qualified service personnel. Servicing is required when the
apparatus has been damaged in any way, such as power-supply cord or plug is
damaged, liquid has been spilled or objects have fallen into the apparatus, the
apparatus has been exposed to rain or moisture, does not operate normally, or has
been dropped.
S3125A
3125A

EMERGENCY COMBINATION SYSTEM
3
ECS-6216MS
Features
Features
Features
- COMPREHENSIVE SYSTEM
It is the system which has RELAY GROUP, SPEAKER SELECTOR, TERMINAL BOARD functions.
- AUTOMATIC FIRE DETECTING FUNCTION
It sends the fire warning automatically with the channel by the fire contact point signal of 16 channels
interlocking with PX-6216.
- MANUAL BROADCAST CONTROL
It can control the broadcasting of the channel you want by controlling the switches on the front side.
- CONTROL THE 3 LINE TYPE SPEAKER TRACK
It consists of the channels for the common and emergency broadcastings to make 3 line type broadcast possible.
- RS-485 COMMUNICATION AND CHANNEL EXPANSION
Long distance transmission is possible and it can be expanded to 160 zones by connecting ECS-6216MS.
- INSTALLATION TIME AND SPACE
It is the comprehensive system and installation is easy. Installation time and space can be saved.

EMERGENCY COMBINATION SYSTEM
4ECS-6216MS
Equipment Setup and Inspection
Equipment Setup and Inspection
1. Setup the Equipment Number
1) Setup the equipment number in accordance with wiring conditions by using rear panel DIP switch.
2) Setup method is shown in below table, and number on the ON switch will be the equipment number.
?Caution Zone display LED will brink if equipment number is not set.
Communication will not be available if equipment numbers are duplicated.
Check the equipment number setting in above case.
3) Zone allocations of set equipment are as follow.
2. TERMINATION Switch (LOAD/OPEN) Setting
1) Termination switch on the rear panel should be set (Load/Open) to stabilize the data transfer in case of
the system linked by using RS-485 communication.
2) Setup the termination switch to LOAD in the equipment which link is started first time and equipment which
link is ended. Setup the other equipment to Open.
?Caution Communication error may occur if setup is wrong.
DIP Switch 1 2 3 4 5 6 7 8 9 10
1 ON
2 ON
Equipment 3 ON
No.
10 ON
Equipment No. 1 2 3 4 5 6 7 8 9 10
ZONE Allocation 1~16 17~32 33~48 49~64 65~80 81~96
97~112 113~128 129~144 145~160
Equipment 1
S/W: LOAD
IN OUT
Equipment 2
S/W: OPEN
IN OUT
Equipment 3
S/W: OPEN
IN OUT
Equipment N
S/W: LOAD
IN OUT

EMERGENCY COMBINATION SYSTEM
5
ECS-6216MS
Front Panel
Front Panel
1. SPEAKER ZONE SELECT BUTTON AND DISPLAY (1~16)
LED will be on the zone selected by the button which selects the individual broadcasting zone.
For emergency broadcast (ES), red light will be pm and green will be on for the common broadcast (PS).
The zone broadcast can be selected only if more than 1 zone in the same bus is being broadcasted.
(Refer to system operation manual)
1

EMERGENCY COMBINATION SYSTEM
6ECS-6216MS
Rear Panel
Rear Panel
1. FIRE SENSOR INPUT TERMINAL
It is the terminal connected to the sensor output in the fire receiving panel and sends the emergency and
evacuation broadcasting to the zone.
1) Through the macro function, broadcasting zones can be memorized for each input channel.
However, it can be set in only Windows program and set information is downloaded from PC to PX-6216
and saved in the internal memory of PX-6216.
2) Maximum 160 zones can be selected and memorized in one input channel.
3) For example, if you want to select and memory the zone 1, 2, and 3 into number 1 channel, and if fire
sensor in number 1 channel is on, emergency broadcasting will be transmitted to number 1, 2, and 3
zones in a same time.
2. PD, COM TERMINAL
1) It is the contact point output terminal used for controlling the operations of the power distributor.
If speaker zone is on or there is no fire sensor input, contact point will be output.
It is connected with REMOTE SW terminal of the power distributor.
2) Com Terminal
It is connected to COM terminal of fire receiving panel.
3. LINK IN/OUT TERMINAL
Link In terminal is connected to previous equipment and Link Out terminal is connected to next equipment.
LINK IN LINK OUT UPGRADE SOURCE 1
RS 232
ADDRESS
12345678910
1234 5678
910 11 12 13141516
1234 5678
91011 12 13 14 15 16
TERM.
LOAD OPEN
1 2 3 4 5 6 7 8
91011 12 13 14 15 16
FIRE
SENSOR
SPEAKER
OUTPUT
AMP
INPUT
H E HCEC E H C E H C E EH C E H C E HC HC HCHCHCHC HCHCHCHC
PD TIMER
EXTCOM
DC 24V
1 2 3
10
4 5 6
7 8 9

EMERGENCY COMBINATION SYSTEM
7
ECS-6216MS
4. TERMINATION SWITCH (LOAD/OPEN)
It is the switch to be set for stabilized data receiving and transmitting of link in/out.
Please refer to Equipment Setting and Inspection (Page 3) for detail information.
?Caution Communication error may occur if setup is wrong.
5. UPGRADE TERMINAL (ISP)
It is the terminal to upgrade the software of the equipment and is not used generally.
6. VOICE FILE CONTROL TERMINAL
It is the communication terminal to be used for controlling our company’s voice file equipment on Windows
program.
1) Connectable Source Equipment products which have RS-232 communication terminal
2) Maximum communication distance is about 12 meter.
3) PIN OUT Specification
7. SPEAKER OUT TERMINAL
It is the terminal which connects the channel speaker. It consists of 3 line type.
1) In PS mode, it is output only from HOT terminal.
2) In ES mode, it is output from both HOT/EM terminal.
8. AMP IN TERMINAL
It is the terminal connected to amp output.
9. ADDRESS SETTING SWITCH
It is the switch to setup the system roles if equipment is expanded and interlocked.
Please refer to Equipment Setting and Inspection (Page 3) for detail information.
PIN NO. Functions
1 RS-485 Data - A
2 RS-485 Data - B
3 RS-485 Data - Z
4 NA
5 GND
6 RS-485 Data - Y
7 NA
8 NA
Pin No. 1 2 3 4 5 6~9
Purpose Not Used Receive Transmit Not Used Ground Not Used

EMERGENCY COMBINATION SYSTEM
8ECS-6216MS
10. POWER INPUT TERMINAL
It is the power input terminal. Caution to polarity and connect DC 24V.
If it is connected with PD(POWER DISTRIBUTOR), connect it to UNSWITCHED Terminal.

EMERGENCY COMBINATION SYSTEM
9
ECS-6216MS
Applications
Applications
LINK IN LINK OUT UPGRADE SOURCE1
RS 232
ADDRESS
12345678910
1 2 34 5 6 78
910 11 12 13141516
12 3 4 5 6 7 8
91011 12 13 14 15 16
TERM.
LOAD OPEN
1 2 3 4 5 6 7 8
9 10111213141516
FIRE
SENSOR
SPEAKER
OUTPUT
AMP
INPUT
H E HCEC E H C E H C E EH C E HCEHC HC HCHCHCHC HCHCHCHC
PDTIMER
EXTCOM
DC 24V
LINK IN LINK OUT UPGRADE SOURCE1
RS 232
ADDRESS
12345678910
1 2 34 5 6 78
91011 12 13 14 15 16
1 2 3 4 5 6 7 8
91011 12 13 14 15 16
TERM.
LOAD OPEN
12345678
9 10111213141516
FIRE
SENSOR
SPEAKER
OUTPUT
AMP
INPUT
H E HCEC E H C E H C E EH C E HCEHC HC HCHCHCHC HCHCHCHC
PD TIMER
EXTCOM
DC 24V
DC OUT
24V
MATRIX
12 0
SIREN/VOLUME
PRE IN REMOTE IN 2 REMOTE IN 1 TIMER INAUTOANN IN PRE OUT
CONTROLOUT (TOAUTO ANN)
EXT INT
AUTO.ANN
REMOTE MIC
MIC SW
EXT INT
HPF
ON OFF
~
AC INPUT
FUSE
DC INPUT
24V
BALANCED
INPUT
1V/10K
LINK
INPUT(ADJ)
12dB 0dB
100V(20.8 )
43.8V(4)
OUTPUT
COM
A
B
70V(10.2)
FRAMEFLOAT
GROUND
LIFT
INPUT OUTPUT
INPUT OUTPUT
LINE
LINK
TERM.
OPEN
LOAD
GND.
FLOAT
FRAME
RM 1 RM 2 RM 3 RM 4 RM 5 RM 6 RM 7 RM 8
INPUT
OUTPUT
DC 24V
SPEAKER
SPEAKER
RME-6108
PROGRAM
TIMER
(PW-6242)
(PW-6242A)
EMERGENCY
PANEL
(EP-6216)
ECS-6216MS
PX-6216
SOURCE
(CD, TUNER
DECK, MIC, ETC.)
ECS-6216MS
POWER
AMPLIFIER
HPF
ON OFF
~
AC INPUT
FUSE
DC INPUT
24V
BALANCED
INPUT
1V/10K
LINK
INPUT(ADJ)
12dB 0dB
100V(20.8 )
43.8V(4)
OUTPUT
COM
A
B
70V(10.2)
FRAMEFLOAT
GROUND
LIFT
POWER
AMPLIFIER
DIB-6000
RM-6024+RM-6012KP
RM #1
RM #1
RM #8
RM #2
RM #3
DIRECT BOX
DIB 6000
+
VOL INPUT OUTPUT
POWER
TOPC
MUTE
LEVEL
INPUT
VOL
+
MIC
PRI.
OFF
ONMAXMIN
LINE
RM-01 PC(GUI)
VOICE FILE
(PV-6242)
PHANTOM
OFF ON
PHANTOM
OFF ON
SOURCE 1 (RS-232) SOURCE3 (RS-232)
VOICE FILE (RS-232) SOURCE 2 (RS-232)
3
4
1
2
CH 8
CH 9
CH 10
CH 7 CH 6 CH 5 CH 4 CH 3
CH 1CH 2CH 3CH 4CH 5CH 6CH 7CH 8
CH 2 CH1 EP
TO EP
TIMER
DATA
INPUT
OUTPUT
RM
DC 24V
IN
OUT

EMERGENCY COMBINATION SYSTEM
10 ECS-6216MS
Block Diagram
Block Diagram
ADDRESS SWITCH
TIMER INPUT
EXT INPUT
KEY INPUT
AMP INPUT
CH1
AMP INPUT
CH2
AMP INPUT
CH16
FIRE CONTACT
INPUT CH1~16 RELAY CONTROL
MCU
EP CONTROL JACK
RS232 COMM PORT1
RS232 COMM PORT2
RS485 COMM
RS485 TERMINATION
SWITCH
FRONT
LED DISPLAY
AMP OUTPUT
CH1
AMP OUTPUT
CH2
AMP OUTPUT
CH16

EMERGENCY COMBINATION SYSTEM
11
ECS-6216MS
ECS-6216MS
Channel 16CH
Communications Protocol LINK IN/OUT RS-485 (1km)
Source & Voice File RS-232 (12m)
Fire Sensor Dry Contact
Operating Temperature -10°C ~ +40°C/14°F~104°F
Power Source DC 24V, 600mA
Weight (Set) 4.3kg/9.5lbs
Dimensions (Set) 482(W)x88(H)x280(D)mm/19(W)x3.5(H)x11(D)in
?Specifications and design are subject to change without notice.
Speci ications
Speci ications
? DIMENSIONS
280
482
88 280
88
482
440

EMERGENCY COMBINATION SYSTEM
12 ECS-6216MS
Service
Service
Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information
provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the
problem is related to the product contact your warranty provider as described in the warranty section of this
manual.
Schematic
A Schematic is available by contacting your warranty provider.
Parts List
A Parts List is available by contacting your warranty provider.
Warranty
Warranty
Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions
of warranty for a given product may be determined first by locating the appropriate country which the product
was purchased in, then by locating the product type.
To obtain specific warranty information and available service locations contact Inter-M directly or the
authorized Inter-M Distributor for your specific country or region.
Variations and Options
Variations and Options
Variations
Variations of this product exist to reflect the variations in AC power requirements throughout the world. Product
supplied through local sources are compatible with local AC power requirements.
Options
No optional items are available for this product.

EMERGENCY COMBINATION SYSTEM
13
ECS-6216MS

MADE IN KOREA
December 2012 129771
Inter-M, Ltd. (Korea) began operations in 1983.
Since then, Inter-M has grown to become one of the largest manufacturers
of professional audio and commercial sound electronics equipment in the world.
Inter-M has gained worldwide recognition for its own branded products,
as well as private label manufacturing of electronics sold under other names (OEM).
The company is no longer just a Korean company, but rather a global company
that is truly international in scope, with factories and offices in Korea and China,
and sales and marketing operations located in Japan, Europe, and the U.S.A.
With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.
Inter-M Americas, INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA
TEL +1-562-921-0313, FAX +1-562-921-0370
Inter-M Corporation
SEOUL OFFICE 653-5 BANGHAK-DONG, DOBONG-KU, SEOUL, KOREA
TEL +82-2-2289-8140~8, FAX +82-2-2289-8149
Other manuals for ECS-6216MS
1
Table of contents
Popular Computer Hardware manuals by other brands

Cobalt Digital Inc
Cobalt Digital Inc 9084 product manual

Intel
Intel X3350 - Xeon 2.66 Ghz 12M L2 Cache 1333MHz FSB LGA775 Quad-Core... specification

Renesas
Renesas SH7147 user manual

iWave
iWave i.MX6 Qseven PMIC SOM Hardware user's guide

GigaDevice Semiconductor
GigaDevice Semiconductor GD32350G-START user guide

Kantech
Kantech IP Link installation manual