Interlogix TruVision Multi-Imager User manual

TruVision 20MP (4 x 5MP)
360 Degree Multi
-Imager
Camera Installation Guide
P/N 1073687-EN • REV A • ISS 20FEB20

Copyright © 2020 United Technologies Corporation,
Interlogix is part of UTC Climate, Controls & Security, a unit of United
Technologies Corporation. All rights reserved.
Trademarks and patents Trade names used in this document may be trademarks or registered
trademarks of the manufacturers or vendors of the respective products.
Disclaimer Information in this document is subject to change without notice. No part of
this document may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, without the express written
permission of UTC Fire & Security Americas Corporation, Inc.
Manufacturer Interlogix.
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, The Netherlands
Certification
FCC compliance Class A: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which
case the user will be required to correct the interference at his own expense.
FCC conditions This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
(1) This device may not cause harmful interference.
(2) This Device must accept any interference received, including interference
that may cause undesired operation.
ACMA compliance Notice! This is a Class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Canada This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-0330 du
Canada.

cUL Safety Instruction:
Improper use or replacement of the battery may result in explosion hazard.
Replace with the same or equivalent type only. Dispose of used batteries in
conformance with the local codes.
Instructions de sécurité :
L’utilisation ou le remplacement inadéquats de la pile peuvent entraîner un
risque d’explosion. Remplacez-la par le même type ou l’équivalent du même
type seulement. Jetez les piles usagées conformément aux directives
fournies par le fabricant de la pile.
European Union
directives
This product and - if applicable - the supplied accessories too are marked
with "CE" and comply therefore with the applicable harmonized European
standards listed under the EMC Directive 2014/30/EU, the RoHS Directive
2011/65/EU.
2012/19/EU (WEEE directive): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collection points.
For more information see: www.recyclethis.info.
2013/56/EU & 2006/66/EC (battery directive): This product contains a battery
that cannot be disposed of as unsorted municipal waste in the European
Union. See the product documentation for specific battery information. The
battery is marked with this symbol, which may include lettering to indicate
cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the
battery to your supplier or to a designated collection point. For more
information see: www.recyclethis.info.
Contact information and
manuals/tools/ firmware
For contact information and to download the latest manuals, tools, and
firmware, go to the web site of your region.
EMEA: firesecurityproducts.com
Manuals are available in several languages.
Australia/New Zealand: utcfs.com.au

Product warnings and
disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE TO AND INSTALLATION
BY QUALIFIED PROFESSIONALS. UTC FIRE & SECURITY CANNOT
PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY BUYING
ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER” OR
“AUTHORIZED RESELLER”, IS PROPERLY TRAINED OR EXPERIENCED
TO CORRECTLY INSTALL FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and product safety information,
please check www.firesecurityproducts.com/policy/product-warning/ or scan
the following code:

Installation Guide 1
Content
Introduction 2
Product overview 2
Installation 2
Installation environment 2
Contact information and manuals/firmware 3
Package contents 4
Cable requirements 5
Camera description 6
Install the camera 7
IR illuminators 9
Accessing the micro SD/SDHC/SDXC slot 10
Mounting accessories 10
Install the camera to a mount 13
Using the camera with an Interlogix NVR or another system 15
Using the camera with TruVision Navigator 15
Specifications 15
Pin definitions 16

2 Installation Guide
Introduction
Product overview
This is the installation manual for TruVision Multi-Imager 360 Degree IP
Camera:
SKU
Description
TV
S-5101
TruVision Multi-Imager 360 Degree IP Camera, 20MP/4 x 5MP image
sensors, 2.8 to 12 mm motorized lenses, True D/N, WDR, 30 m IR, Audio,
Alarm, Micro SD/SDHC /SDXC Slot, IP67, IK10, Heater, Hi-PoE/12 VDC
You can download the following manuals from our web site:
•TruVision 20MP (4 x 5MP) 360 Degree Multi-Imager Camera
Installation Guide
•TruVision 20MP (4 x 5MP) 360 Degree Multi-Imager Camera
Configuration Manual
The manuals are available in several languages on the EMEA web site.
Installation
This chapter provides information on how to install the camera.
Installation environment
When installing your product, consider these factors:
•Electrical: Install electrical wiring carefully. It should be done by
qualified service personnel. Always use a proper Hi-PoE switch or a
12 VDC UL listed Class 2 or CE certified power supply to power the
camera. Do not overload the power cord or adapter.
•Ventilation: Ensure that the location planned for the installation of the
camera is well ventilated.
•Temperature: Do not operate the camera beyond the specified
temperature, humidity or power source ratings. he operating
temperature of the camera is between -40°C to +60°C (40°F to
+140°F). Humidity 95% or less (non-condensing) for the camera.

Installation Guide 3
•Moisture: Do not expose the camera to rain or moisture, or try not to
operate it in wet areas. Turn the power off immediately if the camera is
wet and ask a qualified service person for servicing. Moisture can
damage the camera and also create the danger of electric shock.
•Servicing: Do not attempt to service this camera yourself. Please
refer to the instructions in this manual when removing the camera
cover. Refer all servicing to qualified service personnel.
•Cleaning: Do not touch the bubble with fingers. If cleaning is
necessary, use a clean cloth with some ethanol and wipe the camera
bubble gently.
Contact information and manuals/firmware
For contact information and to download the latest installation and
configuration manuals as well as firmware for this camera, go to the web
site of your region:
EMEA: firesecurityproducts.com
Manuals are available in several languages.
Australia/New Zealand: utcfs.com.au

4 Installation Guide
Package contents
Check the package and contents for visible damage. If any components
are damaged or missing, do not attempt to use the unit; contact the
supplier immediately. If the unit is returned, it must be shipped back in its
original packaging.
•Camera
•Cup base
•Torx wrench
•G3/4 cable gland
(Used on the bubble assembly)
•Screws:
•Water joint
Drywall anchor
6 x 29mm (4 pcs)
Screw M4
9.8 x 25mm (4 pcs)
(Provides water resistance to the
network connection)
Screw M5 (attach the camera to the cup
base) x 10mm (4 pcs)
•Hex wrench 80 x 150 mm
•Water resistant tape (6 pcs)
(Used to lock the mount screws)

Installation Guide 5
•Gray cloth
•Installation manual
•Equipment disposal sheet
•Battery disposal sheet
CAUTION: Use direct plug-in UL listed power supplies marked Class 2/CE
certified or LPS (limited power source) of the required output rating as
listed on the unit.
Cable requirements
For proper operation, adhere to the following cable and power
requirements for the cameras. It is recommended to use CAT 5 cabling or
better. All network cabling must be installed according to applicable codes
and regulations.
The recommended power cable requirements to use are a 12 VDC or Hi-
PoE (802.3at) when connecting the camera.

6 Installation Guide
Camera description
Figure 1: Multi-imager camera
1. Cup base
2. Camera base
3. Hi-PoE and network port
4. Power, 12 VDC
5. Alarm input & output 1
6. Alarm input & output 2
7. RS-485 port
8. Audio out
9. Audio in
10. Lens
11. IR transparent cover
12. Camera positioning tray
13. Lens
14. Reset button
15. SD card slot
16. Access cover for SD card slot and
reset button
17. Lens
18. Lens
19. Bubble assembly

Installation Guide 7
Install the camera
Note: Please refer to the camera configuration guide for detailed
information on the camera configuration.
To install the multi-imager camera to a ceiling:
1. Install the camera base to the ceiling.
a) Use the camera base as a template to mark the mounting holes.
b) If running the cables in to the side of the camera install the cable
gland into the side of the camera base.
2. Install the camera base to the ceiling.
a) Route the cables.
b) Attach the camera safety cable to the camera base.
c) Align the ▲ mark of the camera body with the Unlock mark of
the camera base to ensure that the catches in the camera base
and body are correctly aligned. Then push the camera body
upward.

8 Installation Guide
Attach the safety cable
d) Rotate the camera body to the end according to the direction
arrow below. Make sure the ▲ mark of the camera body is aligned
with the Lock mark of the camera base.
3. Insert the screws to secure the camera body to the base.
4. Adjust the position of the lenses.

Installation Guide 9
Rotation axis. Range: 0° to 355°
Tilting axis. Range: 0° to 135°
Pan adjusting wheel.
Range: -180° to +180°
5. Install the bubble assembly.
Use the Torx wrench to fix the captive screws and secure the bubble
assembly to the camera body.
IR illuminators
The camera’s built-in IR illumination provides high-quality video in low-light
environments, even when there is no other illumination available.
You can configure the IR illumination using a web browser or a client
software. If the function is enabled, the IR light is on when the camera
enters night (black and white) mode. If disabled, the IR light is always off.

10 Installation Guide
The visible IR range may vary due to multiple factors, such as weather, IR
reflection, rate of viewing objects, lens adjustment, and camera settings.
Please refer to the camera datasheet for the standard IR range.
Note: Avoid installing the IR camera near large items, such as, a tree or
wall. The reflection will cause over-exposure and impact the quality of the
image.
Accessing the micro SD/SDHC/SDXC slot
Remove the camera cover ring and insert a micro SD/SDHC/SDXC card
in the slot for local storage as a backup in case the network fails. The
micro SD card is NOT supplied with the camera.
Figure 2: Access the micro SD card in the camera
SD card cover
Video and log files stored on the micro SD card can only be accessed via
the web browser. You can access video from the card using TruVision
Navigator or a recording device, but log files must be accessed via the
web browser interface.
Mounting accessories
The camera can be installed on a cup base (included with the camera)
and then attached to a TruVision wall or pendant mount, which are sold
separately.
Note: The wall and pendant mounts are shipped with installation
hardware.
TruVision Multi-imager camera pendant mount (TVMI-PM)
The multi-imager camera can be installed on a TVMI-PM pendent mount.
The mount length is 116.5 × 57 mm (4.59 × 2.24 in.).

Installation Guide 11
Pendent mount Example: Pendent mount with camera
TruVision Multi-imager camera pendent mount (TVMI-PM2)
The multi-imager camera can be installed on a TVMI-PM2 pendent mount.
The mount length is 116.5 × 200 mm (4.59 × 7.87 in.).
Pendent mount Example: Pendent mount with camera
TruVision Multi-imager camera pendent mount (TVMI-PM3)
The multi-imager camera can be installed on a TVMI-PM3 pendent mount.
The mount length is 116.5 × 500 mm (4.59 × 19.68 in.).
Pendent mount Example: Pendent mount with camera
For further information, please refer to the “TruVision Multi-imager Camera
Mount Installation Guide”.

12 Installation Guide
TruVision Multi-imager camera extension pipe (TVMI-PMA)
The multi-imager camera can be installed on a TVMI-PM/ TVMI-PM2/
TVMI-PM3 pendent mount with TVMI-PMA. The mount length is 364.1 ×
182.0 mm (14.3 × 7.2 in.).
Extension pipe Example: Pendent mount and extension
pipe with camera
For further information, please refer to the “TruVision Multi-imager Camera
Mount Installation Guide”.
TruVision Multi-imager camera wall mount (TVMI-WM)
The multi-imager camera can be installed on a TVMI-WM wall mount.
Wall mount Example: Wall mount with camera
For further information, please refer to the “TruVision Multi-imager Camera
Mount Installation Manual”.

Installation Guide 13
Install the camera to a mount
To install the multi-imager camera to a mount:
1. Install the camera base to the cup base using the screws provided.
2. Route the cables.
3. Attach the cup base to the mount and tighten the screw on the mount
to secure the camera to the mount. Attach the camera safety cable to
the mount.
4. Install the camera body to the camera base.
a) Route the cables.

14 Installation Guide
b) Align the ▲ mark of the camera body with the Unlock mark of
the camera base to ensure that the catches in the camera base
and body are correctly aligned. Then push the camera body
upward.
c) Rotate the camera body to the end according to the direction
arrow below. Make sure the ▲ mark of the camera body is aligned
with the Lock mark of the camera base.
Insert the screws to secure the camera body to the base.

Installation Guide 15
5. See the last two steps of “To install the multi-imager camera to a
ceiling” on page 7 for instructions on positioning the lens and installing
the bubble assembly.
Using the camera with an Interlogix NVR or another
system
Please refer to the NVR/DVR user manuals for instructions on connecting
and operating the camera with these systems.
Using the camera with TruVision Navigator
A camera must be connected to an Interlogix NVR in order to be operated
by TruVision Navigator.
Please refer to the TruVision Navigator user manual for instructions on
operating the camera with TruVision Navigator.
Specifications
Electrical
Voltage input
12 VDC ± 20%, 2.3 A
Power consumption
(Hi-PoE) 42.5 VDC to 57 VDC, 0.6 A to 0.8 A, max. 34 W
Miscellaneous
Connectors
12 VDC, RJ45, I/O, alarm, audio, RS-485
Operating t
emperature -
40 °C to +60 °C (40 °F to +140 °F). Humidity 95% or less
(non-condensing)
Dimensions (Ø × H)
290 × 145.5 mm (11.42 × 5.73 in.) (camera
without the cup
base)
Weight
Camera: Approx. 4.7 kg (10.3 lb.)
With package: Approx. 7.7 kg (16.8 lb.)
Env
ironmental rating IP67 and IK10
Camera dimensions
With cup base:

16 Installation Guide
205 mm
Ø208 mm
20 mm
Ø47mm
44 mm
Ø303mm
Without cup base:
145.5 mm
Ø290mm
Ø208 mm
120 mm
86 mm
83 mm
120 mm
86 mm
46 mm
Pin definitions
There are eight wires on a standard UTP/STP cable and each wire is
color-coded. The following shows the pin allocation and color of straight
and crossover cable connection:
Figure 3: Straight-through cable
1
White/Orange
White/Orange
1
2
Orange
Orange
2
3
White-Green
White-Green
3
4
Blue
Blue
4
5
White/Blue
White/Blue
5
6
Green
Green
6
7
White/Brown
White/Brown
7
8 Brown Brown 8
This manual suits for next models
1
Table of contents
Other Interlogix Digital Camera manuals

Interlogix
Interlogix TruVision 12MP User manual

Interlogix
Interlogix TVC-2401 User manual

Interlogix
Interlogix TruVision 360 Instruction sheet

Interlogix
Interlogix TruVision TVC-6110-1-N User manual

Interlogix
Interlogix UltraView UVC-6120-1 User manual

Interlogix
Interlogix TX-2344-03-1 User manual

Interlogix
Interlogix UVD-XP4DNR User manual

Interlogix
Interlogix TVC-2401 User manual

Interlogix
Interlogix Camera User manual

Interlogix
Interlogix UltraView UVC-6130-1 User manual