Product Summary
This module adds 3G or 4G/LTE cellular radio capability to the
ZeroWire to allow reporting of system events.
Note: UTC reserves the right to check if the UTC SIM card is
used in the correct modem. Improper use of the modem or SIM
card can result in the product to stop operating with the
UltraSync infrastructure.
Installing The Module
1. A mobile phone can provide general guidance on mobile
network coverage.
Look at the signal level on a mobile phone to verify there
are 4/5 to 5/5 bars of reception in the location where you
will install the ZeroWire.
1 bar
2 bars
3 bars
4 bars
5 bars
Low
OK
If the signal strength is low, find another location which
has stronger signal levels.
Note that actual signal level can only be determined using
the ZeroWire connected to a specific network, which may
be different than your phone.
2. If a cellular radio module is pre-installed, skip to the Check
Signal Level section. If not, remove the cover on the right.
3. Locate the 10-pin lead inside the ZeroWire and connect
this to the radio module.
Check Signal Level
1.
Select main menu - Option 4,
System Test.
2.
Enter your Installer code.
3.
Check Cellular Signal Level
4.
Exit from the Advanced
system configuration menu.
Low
OK
-121
-107
-98
-89
-76
-51
•If the reported value is -88 to -51 then the signal level is
OK. In this case, please jump to the Completing
Installation section.
•If the reported value is -121 to -89 then installing an
external antenna is recommended. In this case, follow
steps below to install an external antenna to improve
the signal level.
Note: Remember that signal levels vary day to day and are not
absolute values.
Installing The Optional External Antenna
(ZW-ANT3M)
1. Disconnect the antenna cable from the radio module.
Front View Side View
2. Gently push retaining clips outwards and remove rear
circuit board. This is the internal antenna which will no
longer be needed.
4
MENU
ENTER
INSTALLER CODE
5
MENU
MENU
Part: ZW-HSPA (US) ZW-7000 (EU with SIM card) ZW-7001 (EU without SIM card)
ZW-7041, ZW-7041-ETI (4G radio module without SIM card)

2 / 2 P/N 466-2522 • REV J • ISS 20NOV18
Back View
3. Connect the internal antenna cable from the ZeroWire to
the radio module.
4. Connect a high gain antenna to the antenna socket shown below
and retest signal level.
5. Move the ZeroWire or the antenna to another location if
the signal is still too low.
Completing Installation
1. Insert the whole radio module in to the ZeroWire taking
care not to crimp any cables.
2. Replace the modem cover on the ZeroWire
Specifications
Voltage
5 VDC (provided by panel)
Current
40 mA min / 750mA max at 9 V
Maximum power output @
Wireless operating
frequency
37 dBm @ 880-915 MHz / 925-960 MHz
24 dBm @ 1 920-1 980 MHz / 2 110-
2 170 MHz
External connector
MMCX
Dimensions (W × H × D)
28 × 95 × 18 mm
Storage temperature
–34° to 60°C (−30° to 120°F)
Weight
50 g
Operating environment
Temperature
Relative humidity
0° to 49°C (32° to 120°F)
maximum 90% noncondensing
Regulatory information
Manufacturer
Placed on the market by:
UTC Fire & Security Americas Corporation, Inc.
3211 Progress Drive, Lincolnton, NC, 28092, USA
Authorized EU manufacturing representative:
UTC Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
US/C compliance
FCC ID: XPYSARAU260
IC: 8595A-SARAU260
AUS compliance
EU compliance
INCERT C-001-1301
Product warnings
and disclaimers
THESE PRODUCTS ARE INTENDED FOR SALE
TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT
ANY PERSON OR ENTITY BUYING ITS
PRODUCTS, INCLUDING ANY “AUTHORIZED
DEALER” OR “AUTHORIZED RESELLER”, IS
PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL FIRE AND SECURITY
RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/ or scan the QR code.
European Union
directives
UTC Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of all applicable rules
and regulations, including but not limited to the
Directive 2014/53/EU. For more information see:
https://www.utcfssecurityproducts.eu/
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
www.utcfssecurityproducts.eu/recycle/
Contact information
www.utcfireandsecurity.com
Customer support US
Interlogix Technical Support
Tel +1 855 286 8889 (Option 2)
www.interlogix.com
Customer support Europe
For customer support EMEA, see
www.utcfssecurityproducts.eu
External Antenna
Connector
This manual suits for next models
4