InterVac garage vac GF-120 User manual

RECORD THIS INFORMATION FOR
FUTURE REFERENCES
IF YOU SHOULD HAVE ANY QUESTIONS OR EXPERIENCES A PROBLEM WITH YOUR
INTERVAC PRODUCT,
PLEASE CALL OUR CUSTOMER SERVICE DEPT. AT: 1-888-499-1925
WARNING:
This manual must be read and understood before installation, adjustment, service or
maintenance is performed. This unit should be installed by a qualified technician.
Modification of this product can be extremely hazardous and could result in
personal injury or property damage.
DO NOT RETURN THIS PRODUCT TO THE STORE OR DEALER
Owner read carefully.
Instructions must stay with unit.
InterVac Design Corp., Palm City, FL 34990
Phone 772-463-1400 • USA & Canada toll free 888-499-1925
MODEL NUMBER _______________________
DATE OF PURCHASE ___________________
PLACE OF PURCHASE__________________
1
Manual # W498, rev: 3/18/10
by
MODEL GH-120 (230)
FOR SURFACE ONMOUNTING WALL
OR CABINET
MODEL GF-120 (230)
FOR RECESS/FLUSH MOUNTING IN A
WALL OR CABINET
AS/NZS
RoHs

IMPORTANT SAFETY INSTRUCTIONS
When using an electrical vacuum cleaner, basic precautions should always be followed including the following:
Read all instructions carefully before using this vacuum cleaner.
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Unplug from electrical outlet when not in use and before
servicing.
Do not use on wet surfaces.
Never operate this vacuum cleaner without a dust bag and filters
in place.
Close attention is necessary when used by or near children.Do
not allow unit to be used as a toy.
Use only for intended use as described in this manual. Use only
the manufacturer's recommended attachments and dust bag.
Do not use with damaged cord or plug. If appliance is not working
as it should, has been dropped, damaged, left outdoors, or fell into
water, return the vacuum cleaner to InterVac or an authorized
service dealer for examination and repair.
Do not put any object into openings. Do not use with any openings
blocked; keep free of dust, lint, hair and any other material that
may reduce air flow. If the secondary filter becomes dirty,
rinse in warm water or replace with a new filter. Filter should be
completely dry before using.
Never drop or insert any object into any opening.
Turn off all controls before unplugging.
Do not pull or carry by cord, do not use cord as a handle, do not
close a door on the cord, or pull cord around sharp edges or
corners. Do not run over cord. Keep cord away from
heated surfaces.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
Do not unplug by pulling on cord. To unplug, grasp the plug, not
the cord.
Keep hair, loose clothing, fingers, and all parts of body away
from any openings and all moving parts.
Do not pick up anything that is burning or smoking, such as
cigarettes, matches, or hot ashes.
Use extra caution when cleaning on stairs.
Do not handle plug or appliance with wet hands.
Do not pick up flammable or combustible liquids such as
gasoline, or use in areas where they may be present.
Do not place objects against the vacuum cleaner. Keep area
clear.
Do not step on the hose or pull the hose forcibly.
Do not pick up large objects such as waste paper or cloth,
which may clog the hose.
Do not install this vacuum cleaner in an area exposed to high
temperatures.
Install this vacuum cleaner in a dry place.
Do not attempt to service the vacuum cleaner. Unit is sealed
and cannot be opened without damage to the unit. For service,
call your local authorized service dealer, or InterVac Design's
Customer Care Center.
SAVE THESE INSTRUCTIONS
2
LIMITED WARRANTY
LIMITS AND EXCLUSIONS
InterVac Design Corp. will repair the power unit with new or rebuilt parts, free of charge for six (6) years from the date of original
purchase in the event of a defect in materials or workmanship. No cash refunds. Excluded are the following items that require
normal replacement:
Disposable dust bags, filters, vacuum cleaner tools and vacuum hoses.
This warranty is extended only to the original purchaser. A purchase receipt or other proof of date of original purchase will be
required before warranty performance is rendered.
.
This warranty only covers failures due to defects in materials or workmanship which occurs during normal use and does not
cover damage which occurs in shipment or failures which are caused by products not supplied by InterVac Design, or failures
which result from accident, misuse, abuse, neglect, mishandling, misapplication, alteration, modification, or commercial use
such as hotel, office, restaurant or rental use of the product, or service by anyone other than an authorized service center, or
damage that is attributable to acts of God.
There are no expressed warranties except as listed above.
INTERVAC DESIGN SHALL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM
THE USE OF THIS PRODUCT, OR ARISING OUT OF ANY BREACH OF THIS WARRANTY
. ALL EXPRESSED AND
IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE,ARE LIMITED TO THEAPPLICABLE WARRANTY PERIOD SET FORTHABOVE.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an
implied warranty lasts, so the above exclusions or limitations may not apply to you. This warranty gives you specific legal rights
that vary from state to state. If a problem with this product develops during or after the warranty period, you may contact your
dealer or our service center. If the problem is not handled to your satisfaction, then write to the Customer Service Center at the
company address.
You must return your warranty card or register on our website in order to be covered under these provisions
:
Polarization Instructions for models GH120 volt only.
These appliances have a polarized plug (one blade is wider than the other). This plug will fit in a
polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not
fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.

3
MODEL: GH-120 and GH220
Surface mounting to Wood
Surface mounting to Drywall (½thick) Surfaces: (see Fig.: A)
Step 1a.
Step 2a.
very accurately
Step 3a.
Step . without
Step 5a.
Step 6a
NOTE The hose retainer will fit onto the front panel only if you can read the Warning’ impression correctly.
Step 7a.
Step 1b.
Step 2b.
Step 3b. accurately
Step 4b.
Step 5b.
Step 6b. Very lightly
Step 7b.
Step 8b.
Follow steps 4a through 7a above.
4a
For maximum coverage, choose a wall or surface that is centrally located and has an electrical outlet close by
Remove paper template from the back page of the instruction manual and tape to the wall or surface from step 1.
GarageVac must be installed a minimum of 6 inches from the floor. Mark the centers of the keyholes
with an awl or similar object
Carefully remove template from the wall and place it with the manual for future reference .
Attach four of the #8 screws to the wall as marked on the template leaving the screw heads 1/8” from the
surface of the wall.
To insure the screws are in the proper place, install GarageVac the tool caddy attached by aligning the
keyholes on the back of the unit with the screw heads on the wall and push down on the GarageVac to secure
it in place. If the vacuum cleaner is loose you will need to tighten the screws further
Remove GarageVac from the wall and attach the tool caddy by sliding the “dove tails” on the bottom of the caddy
into the grooves on top of the unit. You will hear a click when the pin on top of the unit clicks into the
corresponding hole on the tool caddy. Install the GarageVac with the tool caddy onto the screw heads as
described in Step 4.
. Place the hose retainer on the front of GarageVac by attaching first the double sided tape to the retainer, watch-
out that the radii match the retainer radii, and press-on firmly.
: ‘
Check to be sure the dust bag and motor filter (located under the dust bag) are in place.
The motor filter should be laying flat in all four corners.
For maximum coverage, choose a wall or surface that is centrally located and has an electrical outlet close by
Remove paper template from the back page of the instruction manual and tape to the wall or surface from step 1.
GarageVac must be installed a minimum of 6 inches from the floor. Align the template so that 2 vertical center points
of the template are aligned with center of a 2x4 stud behind the dry-wall for additional stability.
With an awl or similar pointed object mark the center of the key holes . Carefull remove template
from the wall and place with the manual for future reference.
a 3/32 drill bit, pre-drill all 4 holes.
se a 5/16 drill bit to enlarge the 2 holes which go through the dry-wall without stud support. These are the
holes that require drywall anchors.
Squeeze the two arms of the plastic anchor together and insert through the hole. hammer the anchor
with the dry-wall surface.
Insert the red key-pin and push firmly to toggle the anchor open behind the dry-wall. Remove red pin.
Attach all four #8 screws through the marked keyholes. Keep the screw heads 1/8” from the wall surface.
.
.
.
.
y
Using
Uonly
flush
Specification: 120 Volt, 11 Amp 50/60Hz, Weight 9 lb
230/240 Volt, 6 Amp, 50/60 Hz
Parts List:
Tool Caddy #B051
Hose Retainer #B052
Floor Tool #X404 see page 11
Dash Board Brush #X251 3 dry-wall anchors
Upholstery Tool #X300 1 red push pin
Crevice Tool #X200 6 #8 screws
Telescoping Wand #X154 40” Stretch Hose
Wand Holder #X153
2 high filtration dust bags
Paper Template
#Y08
W600

Fig: A
Fig: B
4
WAND HOLDER Installation:
1:
2:
for wood surface use the 2 screws
supplied with the wand holder package.
for dry-walls use two 1-1/2 long screws
from the fastener package. NOTE: the
wand holder should be mounted against
a wall stud for extra strength.

MODEL: G
Recessed into Wood Surface Installation:
Recessed (flush) installation into Drywall
F-120 and GF220
Specification: 120 Volt, 11 Amp 50/60Hz, Weight 9 lb
230/240 Volt, 6 Amp, 50/60 Hz
GROUNDING INSTRUCTIONS for GF-120 volt only , WHEN PERMANENTLY WIRED
WARNING:
TIP:
Parts List:
Tool Caddy #B051 Hose Hanger #B055 Hose Retainer #B053
Floor Tool #X404 Dash Board Brush #X251 Upholstery Tool #X300
Crevice Tool #X200 Telescoping Wand #X154 Wand Holder #X153
2 Dry-wallAnchor, 1 Red Push Pin 6x #8 Screws 2 Dust Bags #Y08
40” Stretch Hose Paper Template #W605 Double Side Tape
22” long Wood Strip 3 Wire Connectors
Disconnect all electrical power to the wall area before installing!
Do not drill near studs where electrical cable may be secured to studs adjacent to receptacles.
This appliance must be connected to a grounded metal, permanent wiring system; or an
equipment-grounding conductor must be run with the circuit conductors and connected
to the equipment-grounding terminal or lead on the appliance.
Find a place that is close to the garage door so that you can clean your car in the drive
way as well as inside the garage. After you cut the hole for the vacuum you may prefer to
paint the back wall inside the opening with a color matching the vacuum.
Note:
We recommend that the vacuum cleaner be mounted against the side of a wall stud for added stability.
The four mounting holes in the outer corners of the flange of the Vacuum Cleaner must be drilled
from the back of the unit with a 3/16” drill bit when the unit is to be recessed into a wall.
Step 2. ,
Step 3.
Step 4.
Step 5. a
Step 6.
Step 8.
To reach with the vacuum hose as far as possible, choose a wall or surface that is centrally located and has an
electrical outlet or switch from a 16 amp circuit breaker. Make sure the wall is hollow and there are no pipes or
other obstructions in the section you choose.
Tape the template against the wall at a comfortable operating height keep the exhausting air of the vacuum clear
Install 14 or 16 gage(1.0mm) AWG, 300V minimum Romex cable (use wires rated for at least 95C) from the
electrical power supply and pull the power cable through the wall cut-out.
Check to be sure dust bag and motor filter (under dust bag) are in place.
Same procedure as above, but do not use the drywall anchors. Pre-drill the 4 outer holes 3/32 dia. and secure
vacuum cleaner with the 4 painted screws.
:(see Fig.: B)
(see Fig.: B)
TIP:
Step 1 NO
TIP:
W605 - .
b North American installations
c black to black white to white green bare ground conductor
European installations,
double
Drywall installation: with a 3” dia. hole saw, cut a hole first and check for obstructions! It is easier to
re-plaster the 3” dry-wall slug than a large cut-out if you do encounter an obstruction.
The vacuum cleaner should be mounted to the side of a wall stud for added stability. Make sure electrical
switches or outlets are on the installation side of the 2X4, because the body of the vacuum cleaner will be tight
against the stud when installed. Having the power supply in the same cavity of the cut-out will shorten
installation time.
Refer to the paper template # for the cut out
) Open the 2 3/4" x 1 3/8" side cover and pull the 3 inside wires through the opening.
) , Insert your 120 volt power supply cable through the Romex clamp
and out through the side opening.
) With 3 wire nuts connect , and to wires.
(230/240 volt) do not require a ground wire, connect the power
cable to the terminal block inside the housing. The vacuum cleaner is insulated.
d) Tighten the Romex clamp or insert with a pair of plier the plastic clamp and replace the side cover.
Slide the unit, bottom first, into the opening and secure with the four screws.
Use 2 screws for the 2X4 and 2 screws for the 2 anchors. Do not over-tighten.
Step 7.
NOTE The hose retainer will fit onto the front panel only if you can read the Warning’ impression correctly.
Attach the hose retainer to the front of GarageVac by removing the protective paper from the double sided tape
and press-on firmly.
: ‘
The motor filter has to lay flat in all 4 corners, please check.
5

HOW TO OPERATE YOUR
InterVac Design Corporation Palm City, Florida, 34990
in North America toll free 1-888-499-1925
NOTE: THE LOWER PART OF THE VACUUM CLEANER WILL BE QUITE WARM WHEN IN USE.
.
IF THE VACUUM STOPS RUNNING DUE TO OVERHEATING: turn the switch to “O” position
THE THERMAL PROTECTOR ON THE MOTOR WILL RESET AUTOMATICALLY AFTER ABOUT 1-1/2 HOURS.
Replacement bag: Part # Y08 high filtration with Hepa Quality
PLEASE SEE TROUBLE SHOOTING GUIDE.
A. Connecting and disconnecting the hose
B. On / Off Switch
C: How to change the dust bag,
D: To change motor filter, Replacement Part # Y21
1. Lift the inlet valve cover on the front of the door.
2. Insert hose cuff with a o secure.
3. To remove, turn hose in either direction while pulling hose towards you.
1. To start the vacuum cleaner, push the switch to the “I” position.
2. To stop the vacuum cleaner, push the switch to the “O” position.
1. Remove door and dust bag.
2. Reach into the cavity towards the bottom of the vacuum cleaner and remove the motor filter.
3. Replace the filter with a new filter and tuck in the corners so that the on the grid,
4. If necessary, clean the dirty filter by vacuuming or washing in mild soap by hand.
. Let filter dry completely and reuse as needed.
twist and a firm push t
filter lays flat
1. Open the door on the vacuum cleaner by pushing the latch upward and remove both door and dust bag.
2. Carry door and dust bag to the trash container. Remove full bag and discard.
3. Place a new dust bag all the way over the scoop .
4. When closing door, tuck in the top part of the bag, so the door is properly sealed and the latch
clicks into place.
: If you break off the vacuum hose inlet cover, simply reattach it by lining up one of the small dimples located on
the inside of the inlet cover and then press hard on the other side to click into position.
(see Fig.: E)
tight against the door
TIP
Do not clean in washing machine
6

TROUBLE SHOOTING:
NOTE: IF MOTOR SUDDENLY STOPS:
TIP:
CLEANING THE STRETCH HOSE:
TIP :
2.
3.
4.
even if the bag is new.
5.
6.
The stretch hose, besides all its conveniences, has a tendency to get clogged, especially if you have pets.
a)
b)
c)
d)
If you use our very convenient stretch hose, but require more suction power or do not like the pull-back of
the hose we recommend you try our standard 30 foot central vacuum hose. Part # A002-G-CV
1. The most common cause is a clogged hose. See cleaning instructions.
Disconnect vacuum hose from cleaner, hold one end high up in the air and drop a quarter or similar object into
the hose. If the quarter gets stuck the hose is clogged. Try to unclog the hose with a long stick.
The bag is overfilled or fine dust has clogged the bag.
The vacuum cleaning tools are clogged.
Vacuuming large amounts of dust other than household dirt, such as dry-wall or fine wood dust can
block the bag’s pore’s fast,
The motor filter is dirty and should be cleaned or replaced.
If vacuum unit is installed in a tight compartment and air cannot exhaust, the motor can overheat and
shut off until it cooled down.
lift the hose up on both ends and dispense some liquid detergent into both ends.
with a garden hose, holding both ends still up, fill ¾with water.
shake hose up and down, let detergent loosen the dirt.
stretch the hose as far as you can ( 2 people required ) and wash the dirt out with the full pressure of the
garden hose. Repeat if necessary.
E. Replacing motor filter
Part # Y21
tuck-in the corners and sides
carefully under the vertical ribs
CAUTION:
DO NOT PICK UP LIQUIDS, LIT CIGARETTES, HOT ASHES,
RAZOR BLADES, NEEDLES, PINS OR OTHER SHARP OBJECTS!
7
Fig.: E

2 Part Upholstery
Tool with horse hair
PART # X300
Telescoping Wand PART # X154
,
Vacuum Tools supplied
interVac reserves the right to make improvements and modifications without notice.
REPLACEMENT DUST BAGS:
PART # Y08-5 (5 pack) HEPA Type 5 layer fiber filtration
bags for all Intervac Models
NOTE: All Power Units come with 2 Dust Bags
OPTIONAL VACUUM TOOLS
for more information
please go to our web site
30 Foot Traditional
Central Vacuum Hose
PART # A002-G-CV Air Turbo Nozzle
for upholstery
PART # X452
Crevice Tool
PART # X200
8
40’ Stretch Hose with
short grip.
Assembly PART# A002-G
Elongated Brush for Car
Dash Board PART# X251.
Floor Tool with horse hair
PART# X404
Wand Holder
Part # X153
24” Snake Wand to vacuum
in the tightest spaces.
PART # X511

9

10
GF-120
In-wall installation
where the unit fits
flush into a 2x4
stud wall.
Space saving.
Can also be flush
mounted into a
garage cabinet.
Minimum wall
space required.
GH-120
surface
mounted in the
hobby shop.
Can easily be
moved to an
other location.
Compact and
very fast
excess to
vacuum tools
and hose
GH-120
Garage installation
close to the garage
door. This way
cars can be
reached inside and
outside the garage.
Most effective
installation.
Requires minimal
wall space.
Model F120
(GF120 without
the tool caddy)
Installed in the
hallway of a town
house.
Easiest and lowest
cost of having a
central vacuum in
your home.
see our website:
www.intervacdesign.
com
Model RMG120
Installed as a
traditional central
vacuum system with
a vacuum valve in the
living room and the
power unit on the
other side of the wall,
it could be the garage
utility room or closet.
see our website:
www.intervacdesign.
com
INSTALLATION POSSIBILITIES FOR GARAGEVAC
GarageVac Models
other InterVac Models


12
This manual suits for next models
1
Table of contents
Other InterVac Vacuum Cleaner manuals