Protective Mask
FFP2 · KN95 · N95
inveox is a registered trademark owned by inveox GmbH in the European Union, the USA, Switzerland, Canada and the People’s Republic of China
Description The protective mask is comfortable to wear, soft on the skin and designed to lter out up to 95% of the dust, bacteria, viruses,
and mold in the air. It is made up of 4 layers (nonwoven fabric, meltblown fabric, needle-punched cotton, nonwoven fabric)
and can be easily adjusted to the face of the user. In addition, the mask ts well with goggles of various types.
Size 10.7 x 16 cm (4.21 x 6.3 in)
Storage 41–77 °F (5–25 °C)
Expiration 3 years
Precautions 1. Please read the wearing instructions carefully before use.
2. Please do not use the mask if the packaging is damaged.
3. The mast is limited to respiratory protection against non-oily particles only, and is not applicable to special
industries such as anoxic environment, underwater operation, re control and industrial dust protection or
infant respiratory protection.
4. People with abnormal heart and lung function should use the mask with caution.
5. If you feel a signicant increase in breathing resistance, replace it in time.
6. If you have any discomfort or adverse reaction during use, please stop using it immediately.
7. Please keep the mask in a dry, ventilated, non-corrosive environment with a humidity below 80%. Keep
away from ignition sources and ammable materials.
How to use
Open the mask to make the nose
clip at the top, and pull the ear
straps with both your hands.
4.
5.
1. 2.
3.
Hold the mask against your
chin to completely cover
your nose and mouth.
Pull the ear straps behind
your ears and adjust them to
make you feel comfortable.
Use both hands to adjust the shape of the nose
clip. Place your ngers in the middle of the
nose clip and press it inwards while moving
your ngertips along both sides of the nose clip
until it is pressed to t the bridge of your nose.
(Making the nose clip get a seal with only one
hand may affect the tightness of the mask).
Cover the mask with your hand and exhale
vigorously. If you feel the air escaping from the
nose clip, it is required to tighten the nose clip;
if the air escapes from the edge of the mask,
readjust the headband to ensure tightness.
To place an order, please get in touch via email: sampling@inveox.com
Due to high demand and the need to integrate and optimize various supply chains,
the delivered product may vary in appearance and packaging from item in this description.
inveox GmbH • Lichtenbergstraße 8, 85748 Garching bei München, Deutschland
www.inveox.com • Telefon: +49 (0) 89 / 57 84 76 01 • Fax: +49 (0) 89 / 41 41 60 543
inveox is a registered trademark owned by inveox GmbH in the European Union, the USA, Switzerland, Canada and the People’s Republic of China
Execution
Standards
Certication N95 FFP2 KN95
Filter Performance ≥ 95% ≥ 94% ≥ 95%
Total inward leakage* –
tested on human subjects
performing exercise
N/A ≤ 8% leakage
(arithmetic mean)
≤ 8% leakage
(arithmetic mean)
Inhalation resistance
– max pressure drop
≤ 343 Pa ≤ 70 Pa (at 30 L/min)
≤ 240 Pa (at 95 L/min)
≤ 500 Pa (clogging)
≤ 350 Pa
Exhalation resistance
– max pressure drop
≤ 245 Pa ≤ 300 Pa ≤ 250 Pa
Force applied -245 Pa N/A -1180 Pa
CO2 clearance requirement N/A ≤ 1% ≤ 1%
* Total inward leakage (TIL) – the amount of a specic aerosol that enters the tested respirator facepiece via
both lter penetration and faceseal leakage, while a wearer performs a series of exercises in a test chamber.

This manual suits for next models

2

Popular Respiratory Product manuals by other brands

Invacare IRC 1740 Manual del operador

Invacare

Invacare IRC 1740 Manual del operador

Moldex 9000 Series quick start guide

Moldex

Moldex 9000 Series quick start guide

Pulmodyne GO-PAP 313-4600 manual

Pulmodyne

Pulmodyne GO-PAP 313-4600 manual

3M Adflo 35-5401-01 User instructions

3M

3M Adflo 35-5401-01 User instructions

Dräger PSS AirBoss Connect quick start guide

Dräger

Dräger PSS AirBoss Connect quick start guide

AOSafety Respirator Fit Testing Kits and Accessories Specifications

AOSafety

AOSafety Respirator Fit Testing Kits and Accessories Specifications

Air Liquide Respireo N user guide

Air Liquide

Air Liquide Respireo N user guide

Xupermask XUPERFAB user manual

Xupermask

Xupermask XUPERFAB user manual

NIOSH N95 User instruction

NIOSH

NIOSH N95 User instruction

Procare 240392 instruction manual

Procare

Procare 240392 instruction manual

Dpi Sekur SNM 600/1 manual

Dpi Sekur

Dpi Sekur SNM 600/1 manual

Oxyline OxyPro X7 Series quick start guide

Oxyline

Oxyline OxyPro X7 Series quick start guide

SilverCloud Respiro 300 Pro user manual

SilverCloud

SilverCloud Respiro 300 Pro user manual

BLS 8400 Instructions for the use

BLS

BLS 8400 Instructions for the use

Sperian 2000 Series manual

Sperian

Sperian 2000 Series manual

Suzhou Fangtian Industries FT-N062 User instructions

Suzhou Fangtian Industries

Suzhou Fangtian Industries FT-N062 User instructions

MPV Medical MicroDrop Family2 instruction manual

MPV Medical

MPV Medical MicroDrop Family2 instruction manual

Pulmodyne VT Select manual

Pulmodyne

Pulmodyne VT Select manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.