INVISICLEAN IC-7028-Black User manual

1
AIR PURIFIER
with TRUE HEPA FILTER
Model No.: IC-7028-Bla k
READ AND SAVE THESE INSTRUCTIONS:

2
Failure to omply with the warnings listed below may result in ele tri sho k or
serious injury
This produ t should be used only in a ordan e with the spe ifi ations outlined
in this manual. Usage other than what has been spe ified here may result in
serious injury.
WARNING: The cords, wires and/or cab es supp ied with this product
contain chemica s, inc uding ead or ead compounds, known to the state
of Ca ifornia to cause cancer and birth defects or other reproductive harm.
Wash hands after using. (Ca ifornia Code of Regu ations Proposition 65)
When using ele tri al applian es, basi pre autions should always be followed to
redu e the risk of fire, ele tri sho k and injury to persons, in luding the following:
• Read all instru tions before using applian e.
• IMPORTANT - This applian e has a polarized plug (one blade is wider than
the other).
• To redu e the risk of ele tri sho k, this plug is intended to fit in a polarized
outlet only one way. If the plug does not fit fully in the outlet, reverse the
plug. If it still does not fit, onta t a qualified ele tri ian. Do not attempt to
defeat this safety feature.
• To avoid fire or sho k hazard, plug the applian e dire tly into a 120V AC
ele tri al outlet.
• Keep the ord out of heavy traffi areas. To avoid fire hazard, NEVER put the
ord under rugs, near heat registers, radiator, stoves or heaters.
• To prote t against ele tri al hazards, DO NOT immerse in water or other
liquids. Do not use near water.
• Children annot re ognize the hazards asso iated with the usage of ele tri al
applian es. For this reason, always supervise hildren when they are near the
unit.

3
• Always unplug the air purifier before moving it, opening the grill, hanging
filters, leaning or whenever the air purifier is not in use. Be sure to pull by
the plug and not the ord.
• NEVER drop or insert any obje t into any openings.
• DO NOT run ord under arpeting.
• DO NOT over ord with throw rugs, runners, or similar overings.
• DO NOT route ord under furniture or applian es. Arrange ord away from
traffi area and where it will not be tripped over.
• DO NOT operate any applian e with a damaged ord or plug, if motor fan
fails to rotate, after the applian e malfun tions, or if it has been dropped or
damaged in any manner.
• Use applian e only for intended household use as des ribed in this manual.
Any other use not re ommended by the manufa turer may ause fire,
ele tri sho k or injury to persons.
• DO NOT use outdoors.
• DO NOT pla e anything on top of unit.
MAIN PARTS

4
OPERATION
PREPARING FOR FIRST USE
1. Carefully unpa k your air purifier from the box and remove from the plasti bag.
2. Sele t a firm, level, and flat lo ation. For proper air flow, pla e the unit at least 1
foot from any wall or furniture. Ensure no grills are blo ked.
3. Plug the power ord into a 120V AC outlet.
4. Always lift your air purifier by the handle of the unit.

5
Figure 1
OPERATING INSTRUCTIONS
The air purifier may be operated by the manual ontrols lo ated on the air purifier
(as shown in Figure 1).
1. Turn the air purifier on by pressing On/Off Button, press On/Off Button
again to turn off the ma hine.
2.
Turn on the UV-C lamp and Ionizer ON or OFF by using UV&ION Button.
Press the UV&ION Button to y le through the following modes:
Mode 1 – Both UV lamp and Ionizer are on.
Mode 2 – Ionizer off, UV lamp on.
Mode 3 – Ionizer on, UV lamp off.
Mode 4 – Both UV lamp and Ionizer are off.
3. Press Fan Speed Button to sele t fan speed MODE 1-3.
(1= lowest speed setting; 3= highest speed setting)
4. To turn the air purifier off, press the On/Off Button.

6
TIMER FUNCTION:
This fun tion will work in any mode. The timer fun tion allows you to set the length
of operation from 1 hour (1H) to 8 hours (8H). Press Timer Button to set your
desired operation time. On e the timer is set, the timer indi ator will lit and the timer
will ount down the hours till the air purifier turn itself off. Pressing Timer Button
on e more after the timer indi ator refle ts 8 hours (8H) will reset the air purifier to
ontinuous running.
HEPA RESET FUNCTION:
If the HEPA filter needs to be repla ed, the HEPA Fi ter Reset Indicator on LCD
will blink. After repla ing the HEPA filter, reset the HEPA Fi ter Indicator by
pressing HEPA RESET Button, and the indi ator will stop blinking. Pressing HEPA
RESET Button during normal use, when the indi ator is not blinking, will not do
anything.
CLEANING AND MAINTENANCE

7
Figure 3
CLEANING or REPLACING HEPA FILTER (See Figure 3)
1. Turn off and unplug the unit. Press the lo k & release button and remove the
rear over from the unit.
2. Take out the used filter and dis ard it properly. (See Figure 4)

8
Figure 4
3.
Atta h the pre-filter to the HEPA filter using Vel ro and insert the new HEPA filter.
4.
Install the rear over ba k onto the unit and se urely lat h in pla e.
(See Figure 5)
Figure 5
NOTE: Do not use water or any other household leaners to lean the HEPA filter.
Due to varying environmental onditions, the filter may need to be repla ed earlier
or later than indi ated by the HEPA Fi ter Reset Indicator. If the HEPA filter turns
from white to dark grey or bla k, it means you need to hange the filter. If the HEPA
filter is still white, it does NOT need to be repla ed, even if the HEPA Fi ter Reset
Indicator on the LCD is blinking. Please onta t the manufa turer to pur hase a
new HEPA filter.

9
CLEANING PRE-FILTER (See Figure 6)
1. Turn off and unplug the unit.
2. Press the Lo k & Release Button and remove the Rear Cover from the unit.
3. Remove the pre-filter from the HEPA Fi ter. Clean the pre-filter with va uum
brush atta hment of your va uum leaner. This will remove lint and dirt from the
filter.
Figure 6
4. After leaning, reatta h the pre-filter to the HEPA Fi ter and install the rear
over ba k to unit and se urely lat h in pla e.
5. To ensure optimal performan e, lean the pre-filter often.
REMOVING/INSTALLING UV LAMP
1. To a ess the UV lamp, remove the rear over and HEPA filter. After removing
HEPA filter, use a s rewdriver to remove the four s rews holding the UV shield
and remove the UV shield. (See Figure 7)

10
Figure 7
2. To remove the UV lamp, rotate it 1/4 turn and then slide it out of the top and
bottom lamp so kets. (See Figure 8)
Figure 8
3. To install the UV lamp, slide it into the top and bottom lamp so kets and rotate it
1/4 turn.
4. The UV lamp should be repla ed on e a year.
MAINTENANCE

11
1. The air purifier should be he ked on e a month.
2. Clean the pre-filter with the va uum leaner, whi h will remove lint and dirt.
3. Use a lean, dry, soft loth to wipe the external surfa e of unit.
NOTE: Do not sti k any foreign obje ts or your fingers into the unit.
CAUTION:
Do not use gaso ine, benzine, thinner, harsh c eaners, etc., as
they wi damage the product. NEVER use ALCOHOL OR SOLVENTS.
TROUBLE SHOOTING TIPS
If the air purifier shuts off unexpe tedly, safety features may have been a tivated to
prevent damage or injury. If this happens:
1. Make sure the air purifier is plugged into a working ele tri al outlet.
2. Make sure the HEPA filter is firmly seated in pla e.
3. Make sure the rear over is lat hed firmly in pla e.
NOTE: IF YOU CONTINUE TO EXPERIENCE A PROBLEM, PLEASE RETURN THE AIR
PURIFIER TO THE PLACE OF ORIGINAL PURCHASE. DO NOT ATTEMPT TO TAKE
APART THE UNIT BY YOURSELF. DOING SO WILL VOID YOUR WARRANTY AND
MAY CAUSE DAMAGE TO THE PRODUCT OR PERSONAL INJURY.

12
3 YEAR LIMITED WARRANTY
To the onsumer, InvisiClean warrants this produ t to be free of defe ts in materials
or workmanship ommen ing upon the date of the original pur hase. Save your
original sales re eipt to validate start of warranty period. Warranty is not valid
without re eipt
.
If this produ t should be ome defe tive within the warranty period, we will repair or
repla e any defe tive parts free of harge. All warranty repairs must be ompleted
by InvisiClean. This warranty does not over unauthorized repairs. The warranty
does not in lude unusual wear, damage resulting from a ident, or unreasonable
use of the produ t. This warranty only overs the produ t when used with genuine
InvisiClean a essories. This warranty overs produ t that was pur hased from
authorized distributors. This warranty gives you spe ifi legal rights and you may
also have other rights (other rights may vary from state to state in the U.S.A.).
To submit produ t under warranty the omplete ma hine must be delivered pre-paid
to InvisiClean. Please in lude omplete information in luding: the problem, the
model number of the produ t, the day of pur hase, and a opy of the original sales
re eipt along with your name, address, and telephone (email optional). Please
onta t the original authorized retailer for return authorization and instru tions.
Table of contents
Other INVISICLEAN Air Cleaner manuals