IP DOOR ENTRY BATICONNECT IPGUARD MINI User manual

4G/IP/GSMSMART VISITOR ENTRY PANEL
INSTALLATION MANUAL
4G/IP/GSM SMART
Visitor Door Entry
IPGUARD MINI IPGUARD MINI PLUS IPGUARD MINI TOUCH
IPGUARD®& BATICONNECT®

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
1
-
+
E1
GND
D2D2
SIM
CARD
-
+
-
+
2
1
E2
C
NC
RJ45
NO
EXIT BUTTON
RESET
BUTTON
POWER IN
3-core 1.5mm² flex cable (3183Y)
12VDC / 5A
EVE196-X3-RS
PROXIMITY
CONTROL
UNIT
(Only used if integral proximity reader
and EVE196-X3-RS control unit is not used)
LOCK OUTPUT RELAY
Lock circuit cable ref.
4 x 1 YY/LSZH per lock
(4-core, 1mm²/core)
INTERNAL OR
EXTERNAL AERIAL
LOCK RELAY 1
12VDC
TRIGGER
RELAY 1
4G/IP ROUTER CONNECTION
Class E (CAT6) U/UTP
(Option 2. Only required if 4G
aerial needs to go on the roof)
PRE-INSTALLED
Class E (CAT6) U/UTP IPGUARD PANEL
IPGUARD PANEL
TOP
4G/IP ROUTER
CONNECTION
(OPTIONAL)
SIM CARD
EVE196-X3-RS
CONNECTION
EXIT BUTTON
POWER IN
LOCK OUTPUT
RELAY 1
RESET
BUTTON
INTERNAL OR
EXTERNAL
AERIAL
SCREW ON
CONNECTOR
Unscrew nut to remove internal default aerial and
screw-on the external aerial cable in its place.
INTERNAL
AERIAL
ZAN1055 external
remote aerial. Used if
4G signal to the panel
is low, or simply to
improve signal strength
Supplied with 5 metres
of cable.

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
2
-
+
E1
GND
D2
SIM
CARD
-
+
E2
C
NC
RJ45
NO
INTERNAL OR
EXTERNAL AERIAL
12VDC
TRIGGER
RELAY 1
PROXIMITY READER
CONTROL UNIT
12V DC ELECTRIC
FAIL SECURE RELEASE
EXIT
BUTTON
IPGUARD PANEL
AR125
AR122
EVE196-X3-RS
LOCK RELAY 1*
-
+
-
+
+NO C NC 4 5 6 7 8 9-
D2D1
EXIT
BUTTON
COAX
PROX
LOCK OUTPUT
RELAY
12VDC
Class E (CAT6) U/UTP
1 2
+ -
3-core 1.5mm2 ex cable (3183Y)
+
-
VARISTOR
OR DIODE
4 x 1 YY/LSZH per lock
(4-core, 1mm2/core)
AR125 (12VDC/5A)
for IPGUARD
and EVE196-X3-RS
AR122 (12VDC/2A)
for locking
IPGUARD PANEL WITH INTEGRAL PROXIMITY READER
FAIL SECURE LOCKING
*The lock relay output on the EVE196-X3-RS
is normally used to control the lock.
*The EVE196-X3-RS used for the IPGUARD
needs to have the RS485 protocol 5.

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
3
-
+
E1
GND
D2
SIM
CARD
-
+
E2
C
NC
RJ45
NO
12VDC
TRIGGER
RELAY 1
PROXIMITY READER
CONTROL UNIT
12V DC MAGNET
OR FAIL SAFE RELEASE
EXIT
BUTTON
IPGUARD PANEL
AR125
AR122
EVE196-X3-RS
EMEX
If your fail safe locking requires an Emergency Breakglass
Exit Device (EMEX with a normally closed contact) to
comply with Building Safety regulations, please t as shown.
LOCK RELAY 1*
INTERNAL OR
EXTERNAL AERIAL
-
+
-
+
+NO C NC 4 5 6 7 8 9-
D2D1
EXIT
BUTTON
COAX
PROX
LOCK OUTPUT
RELAY
12VDC
Class E (CAT6) U/UTP
1 2
+ -
3-core 1.5mm2 ex cable (3183Y)
+
-
VARISTOR
OR DIODE
4 x 1 YY/LSZH per lock
(4-core, 1mm2/core)
IPGUARD PANEL WITH INTEGRAL PROXIMITY READER
FAIL SAFE LOCKING
*The lock relay output on the
EVE196-X3-RS is normally
used to control the lock.
AR122 (12VDC/2A)
for locking
EVE196-X3-RS’s connected to the
IPGUARD need to be programmed
as the rst in the chain (i.e RS485
address =1).
Each IPGUARD & EVE196-X3-RS
needs to be installed in their own bus
chains/network (not wired together).
AR125 (12VDC/5A)
for IPGUARD
and EVE196-X3-RS

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
4
The EVE196-X3-RS’s connected to the IPGUARD need to be
programmed as the first in the chain (i.e RS485 address =1)
Each IPGUARD and EVE196-X3-
RS needs to be installed in their
own bus chain/network (not
wired together).
The network/chains are
programmed and linked
together in the cloud via
www.baticonnect.com
RS485 = 1 ✔
RS485 = 1 ✔RS485 = 2 ✘
RS485 = 1 ✔
✘✘
✔✔

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
5
EVE196-X3-RS PROXIMITY READER CONTROL UNIT
FOR PROXIMITY READER INTERNAL TO IPGUARD PANEL
+NO C NC 4 5 6 7 8 9-
D2D1
EXIT
BUTTON
COAX
PROX
LOCK OUTPUT
RELAY
POWER FOR EVE196-X3
(NOT FOR LOCKING)
12VDC / 2AMP POWER
3-core 1.5mm
ex cable (3183Y)
EXIT
BUTTON
12VDC
Class E (CAT6) U/UTP
EVE196-X3
1 2
+ -
+-
EVE196-X3-RS
(Network address 01)
TOP
IPGUARD PANEL
BOTTOM
EXIT BUTTON
D2 ON IPGUARD
12VDC / 5AMP POWER
LOCK
OUTPUT
RELAY*
- +
*The lock relay output on the EVE196-X3-RS
is normally used to control the lock.

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
6
EVE196-X3-RS PROXIMITY READER CONTROL UNIT
WITH MLP8-RS PROXIMITY READER ANTI-VANDAL
EXTRA PROX
DOORS ONLY
+NO C NC 4 5 6 7 8 9-
D2D1
D2
D1
EXIT
BUTTON
COAX
PROX
LOCK OUTPUT
RELAY
POWER FOR EVE196-X3-RS
(NOT FOR LOCKING)
12VDC / 2AMP POWER
3-core 1.5mm
ex cable (3183Y)
EXIT
BUTTON
12VDC
+-+-
12VDC
Class E (CAT6) U/UTP Class E (CAT6) U/UTP
RS PROXIMITY READER
EVE196-X3-RS
CONTROL UNIT
NEXT EVE196-X3-RS
ON NETWORK
1 2
+ -
Class E (CAT6) U/UTP
NEXT EVE196-X3-RS
EVE196-X3-RS
1 2
+ -
LPERS
All proximity readers are installed in the same manner (LPERS, LPMRS and LPTRS)
*The EVE196-X3-RS used for the PROXIMITY READER needs to have the RS485 protocol 3.

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
7
NETWORKING EXTRA DOORS ONTO IPGUARD PANEL
-
+
E1
GND
D2
RT
ON OFF
SIM
CARD
-
+
E2
C
NC
RJ45
NO
LOCK RELAY 1
12VDC
TRIGGER
RELAY 1
IPGUARD PANEL
DOOR 1
IPGUARD DOOR
(Network address 01)
DOOR 4
(Network address 04)
DOOR 2
(Network address 02)
DOOR 3
(Network address 03)
LAST DOOR
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
COAX
PROX
COAX
PROX
COAX
PROX
COAX
PROX
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT FOR
PROXIMITY READER INTEGRAL TO IPGUARD
Class E (CAT6) U/UTP
Class E (CAT6) U/UTP
1 2
+ -
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
Class E (CAT6) U/UTP
1 2
+ -
+NO C NC 4 5 6 7 8 9-
D2
EXIT
BUTTON
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
Class E (CAT6) U/UTP
Fit a 120Ω (OHM) resistor
1 2
+ -
+NO C NC 4 5 6 7 8 9-
D2
D1
D1
D1
D1
EXIT
BUTTON
120Ω
LOCK OUTPUT
RELAY
12VDC
EVE196-X3-RS CONTROL UNIT
1 2
+ -
INTERNAL OR
EXTERNAL AERIAL
PRE-PROGRAMMED by IP
Door Entry ltd as Door 1,
Door 2, Door 7 etc.
Trained installers equipped
with TELU programmer
can program default
EVE196-X3-RS door
setting themselves. All
actual system operational
programming is via
www.baticonnect.com
When networking multiple
doors to the IPGUARD,
switch on RT on the
IPGUARD’s board.
Maximum 10 doors per IPGUARD®
panel. Additional doors can be added
by creating additional networks in
conjunction with our IGSM data modems.
At the end of the bus chain / network, YOU MUST add resistance
either by switching on RT2 on the last EVE only or by adding a
120 (OHM) resistor, as shown above.

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
8
FOR
INFORMATION
ONLY
NO C NC 4 5
+-
12V DC MAGNET
OR FAIL SAFE RELEASE
VARISTOR
OR DIODE
EXIT BUTTON
EMEX
LOCK OUTPUT RELAY
If your fail safe locking requires an Emergency
Breakglass Exit Device (EMEX with a normally
closed contact) to comply with Building Safety
regulations, please t as shown.
TO +
+
-
12VDC/2AMP
DEDICATED PSU
EVE196-X3-RS CONTROL UNIT
FAIL SECURE LOCKING
EVE196-X3-RS CONTROL UNIT
AUTOMATION CONTROL / VOLT-FREE
EVE196-X3-RS CONTROL UNIT
FAIL SAFE LOCKING
NO C NC 4 5
+
-
12V DC
FAIL SECURE
ELECTRIC RELEASE
VARISTOR
OR DIODE
EXIT BUTTON
12VDC/2AMP
DEDICATED PSU
FOR
INFORMATION
ONLY
TO +
+ -
FOR
INFORMATION
ONLY
NO C NC 4 5
TO AUTOMATION
CONTROL
EXIT
BUTTON
IMPORTANT!
1. A diode or varistor must be
tted across the lock power
terminals as clearly shown.
2. Use separate power supplies
for (a) the electric locking
(b) the IPGUARD panel.
3. The IPGUARD back box and/or
any metal work connected to
the IPGUARD must be earthed.
Failure to comply invalidates all
warranties.

4G/IP/GSM SMART
Visitor Door Entry INSTALLATION CABLING
9
NO
C
NC
+
-12V DC FAIL SECURE
ELECTRIC RELEASE
VARISTOR
OR DIODE
LOCK OUTPUT
RELAY
FOR
INFORMATION
ONLY
TO +
+ -
12VDC/2AMP
DEDICATED PSU
FOR
INFORMATION
ONLY
NO
C
NC
VARISTOR
OR DIODE
LOCK OUTPUT
RELAY
+
-
12V DC MAGNET OR
FAIL SAFE RELEASE
If your fail safe locking requires an Emergency
Breakglass Exit Device (EMEX with a normally
closed contact) to comply with Building Safety
regulations, please t as shown.
EMEX
TO +
+ -
12VDC/2AMP
DEDICATED PSU
FOR
INFORMATION
ONLY
NO
C
NC
LOCK OUTPUT
RELAY
TO AUTOMATION
CONTROL
FAIL SECURE LOCKING
IPGUARD RELAY 1
FAIL SAFE LOCKING
IPGUARD RELAY 1
AUTOMATION CONTROL / VOLT-FREE
IPGUARD RELAY 1
This manual suits for next models
2
Table of contents