IS Technologies ULM-1000C User manual

©ISTechnologiesCo.,Ltd. PAGE1/ 41
Please read this manual attentively before installation

©ISTechnologiesCo.,Ltd. PAGE2/ 41
Contents
ABOUT THIS MANUAL ......................................................................................... 4
I. SAFETY GUIDE INSTRUCTION ......................................................................... 6
1. Authorized Personnel ............................................................................................................ 6
2. Operation ................................................................................................................................. 6
3. Cautions ................................................................................................................................... 6
4. Product Inspection ................................................................................................................ 6
5. Symbols .................................................................................................................................... 7
II
. PRODUCT ............................................................................................................ 9
1. Principle of operation .........................................................................................................10
2. Specification ..........................................................................................................................11
3. Product Package ..................................................................................................................12
4. Dimension .............................................................................................................................12
III. INSTALLATION .............................................................................................. 14
1.
General Guide .......................................................................................................................14
2. Mounting ...............................................................................................................................15
3. Installation Condition .........................................................................................................17
IV. WIRING ........................................................................................................... 19
1. Wiring .....................................................................................................................................19
2. Power ......................................................................................................................................19
V. OPERATION ..................................................................................................... 21
1. Start-up Display ...................................................................................................................21
[Pic1. Start-up Display] ...........................................................................................................21
[Pic2. Start-up Display .............................................................................................................21
2. Display ....................................................................................................................................22
3. Buttons ...................................................................................................................................24

©ISTechnologiesCo.,Ltd. PAGE3/ 41
VI. PROGRAMING ............................................................................................... 27
1. Application Menu ................................................................................................................27
2. Current Output Menu .........................................................................................................29
3. Compensation Menu ...........................................................................................................31
4. Outputs Simulation Menu .................................................................................................34
5. Password Menu ....................................................................................................................35
VII. MAINTENANCE ............................................................................................ 37
Warranty Period ........................................................................................................................37
Repair Service ............................................................................................................................37
VIII. TROUBLE SHOOTING ................................................................................ 39

©ISTechnologiesCo.,Ltd. PAGE4/ 41
About this Manual
This manual provides important information about the installation, wiring,
operation, and control of ULM-1000C. Please read this manual before
installing or operating the product. In addition to operating the product, this
manual is very important. Please keep it in a safe place for easy reference.
This manual is provided an electronic version only. The electric version is
provided with the product package or it can be downloaded through our
website (www.sondar.com).
Please note that the contents of this manual are subject to change without
prior notice if the product is modied, upgraded or improved.
Although we have checked all contents of this manual but there would be the
possibility to remain errors. Therefore the contents of this manual are
regularly updated. We welcome all suggestions for improvement.
SONDAR is a registered trademark of IS Technologies Co., Ltd.
Without our prior written permission, reproduction, distribution or any use
of manual contents are strictly prohibited.
Copyright IS Technologies Co., Ltd. 2013. All right reserved.

©ISTechnologiesCo.,Ltd. PAGE5/ 41
Safety Guide Instruction

©ISTechnologiesCo.,Ltd. PAGE6/ 41
I. Safety Guide Instruction
1. Authorized Personnel
The installation and operation of the product must be carried out by licensed
experts or qualied personnel. Please always wear protective equipment when
operating the products.
2. Operation
Before operating the unit, please read this manual thoroughly. The
manufacturer isn’t responsible for ’accidents caused by user s misuse or
’modication of the product without manufacture s permission. Conduct
periodic inspection of the product.
3. Cautions
This manual provides all information you need to operate ULM-1000C,
maintain and trouble oot. Please follow the instructions in this manual.
The manufacturer is not responsible in any way for the risk of an accident
when user doesn’t follow the instructions.
4. Product Inspection
When opening the product package box, look carefully to determine if the
products or accessories have been damaged or contaminated. If the product
has been damaged, it may not function properly.

©ISTechnologiesCo.,Ltd. PAGE7/ 41
5. Symbols
Caution:
If it is ignored, faults or malfunctions could be result.
Warning:
If it is ignored, injury to people and serious damage to
the instrument could be result.
Electric Shock
If it is ignored, the product could be damaged by
electric ock
Information:
It provides additional information.

©ISTechnologiesCo.,Ltd. PAGE8/ 41
Product Description
ULM-1000C

©ISTechnologiesCo.,Ltd. PAGE9/ 41
II
. PRODUCT
ULM-1000C is an ultrasonic non-contacting level meter which will increase
the eectiveness of your liquid management process. It is designed its sensor
and controller in one compact housing. ULM-1000C is two-wire loop-powered
instrument and its measurement range is 6 meters.
ULM-1000C menu makes the user easy and simple for calibration. All
functions are optimized which enables you to eectively monitor the liquid
level and keep your facilities running safely and reliably.
Application:
ULM-1000C is suitable for liquids level monitoring in all industries,
particularly in the water and wastewater industry.
• Depending on the sensor material, the application can be
restricted. Before installing the sensor, please check the chemical
compatibility chart.

©ISTechnologiesCo.,Ltd. PAGE10 / 41
1. Principle of operation
The sensor transmits ultrasonic pulses to the measurement target. The pulses
are reected from the surface of the target and received back by the sensor.
The running time is converted into the distance and it ows as level or
volume on the display.
=D(C•T)/2
D: DISTANCE
C: SOUND VELOCITY
T: TIME OF FLIGHT
•
Distance: from the sensor bottom to surface of the target
•
Level: from the bottom of storage to surface of the target
•
Empty: from the sensor bottom to the bottom of storage

©ISTechnologiesCo.,Ltd. PAGE11 / 41
2. Specification
ULM-1000C
Measurement Ultrasonic non-contacting
Measuring Range 0.3 to 6.0m (0.98 to 19.6)
Accuracy %0.2 of F.S
Bean Angle 8˚at -3dB
Resolution 1mm or 0.03% of F.S
Damping Rate 0.1m/min - 100m/min adjustable
Output Analog Analog ~4 20mA, into max 60 Ω0
Display 5 Digit LCD
Material Polypropylene
IP Rating IP67
Process Connection 2” PF
Temperature -20℃~70℃(-4℉~158℉) for Sensor
-20℃~60℃(-4℉~140℉) for LCD
Temperature Compensation by a built-in temperature sensor
Dimension 117 ×(W) 120(H)x209(D) mm
Weight ca. 1kg
Power Supply DC 20~30V
Power Consumption less than 0.022A
* The Specication is subject to change without prior notice.

©ISTechnologiesCo.,Ltd. PAGE12 / 41
3. Product Package
(PG13.5)
ULM-1000C
Manual CD Cable Grand
X
1TestReport
4. Dimension
The enclosure material is polypropylene and the protection grade is IP67.

©ISTechnologiesCo.,Ltd. PAGE13 / 41
INSTALLATION

©ISTechnologiesCo.,Ltd. PAGE14 / 41
III. Installation
1. General Guide
Before installing the product, read this manual and specication. It is
installed in a place that is within the temperature range specied in this
manual and that is suitable to the enclosure rating and materials. If the
products are installed improperly, it may cause malfunction.
This is general guide for installing SONDAR ultrasonic products.
Remove the obstacles in the space between the sensor and the measured target
such as ladders, limit switches, heating spirals etc.
When mounting the sensor, keep the distance to the vessel wall.
The bottom of the sensor ould be perpendicular to the surface of water.
Do not set the maximum level into the Dead Zone range.
Avoid the intense winds and excessive exposure to direct sunlight. The strong
winds change the path of ultrasound and may cause a malfunction. If you need
to install the unit in a spot exposed to direct sunlight, sun screen must be
installed.
Keep the distance from the place where are strong noise by high voltage, high
current etc.
Install the unit in the place vibration free.
Use the product in accordance with its specications.

©ISTechnologiesCo.,Ltd. PAGE15 / 41
2. Mounting
ULM-1000C can be mounted with a mounting bracket or with screw in ange
or in many other ways. This manual explains two typical mounting types of
ULM-1000C.
2-1. Installation with mounting bracket
• If the equipment is installed or used in a manner not specified in
this manual, then the protection provided by the equipment may
be impaired.

©ISTechnologiesCo.,Ltd. PAGE16 / 41
2-1. Installation with screw in a flange
• The nozzle length shouldn’t be exceeded the maximum length
above. Shorter setting is better.
• The nozzle should be free of obstructions such as weld seams.
Nozzle Diameter(D) Maximum Nozzle Length(L)
80mm 240mm
100mm 300mm
150mm 430mm
200mm 570mm
D L

©ISTechnologiesCo.,Ltd. PAGE17 / 41
3. Installation Condition
Do not install the sensor in or
above a lling ow outlet. Secure
enough distance from the lling
ow.
When mounting the sensor, keep
the distance to the vessel wall.
The bottom of the sensor ould be
perpendicular to the surface of
water.
Do not set the maximum level(100
%
of Span)
into the Dead Zone range

©ISTechnologiesCo.,Ltd. PAGE18 / 41
Wiring

©ISTechnologiesCo.,Ltd. PAGE19 / 41
IV. Wiring
1. Wiring
The ULM-1000C Series terminal connection is as detailed below. Wiring
details are also given on the terminals under the access cover.
• If the equipment is installed or used in a manner not specified in
this manual, then the protection provided by the equipment may
be impaired.
2. Power
The standard power type is DC power. The power range is DC20-30V.
• When turning on the power of ULM-1000C for the first time,
make sure any connected devices are disabled until all system
functions are confirmed and to be operating properly.

©ISTechnologiesCo.,Ltd. PAGE20 / 41
Operation
This manual suits for next models
1
Table of contents
Other IS Technologies Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Casella
Casella dBadge2 HB4056-07 user manual

Lumantek
Lumantek WEIVER 2.0 Operation manual

Brooks
Brooks SLA5850 Installation and operation manual

Ludlum Measurements
Ludlum Measurements 4530-4200 installation manual

HT Instruments
HT Instruments FLASHMETER PRO user manual

Bosch
Bosch FSA 720 instruction manual

Extech Instruments
Extech Instruments SL250W quick start

PCB Piezotronics
PCB Piezotronics 393M89 Installation and operating manual

PDK
PDK PDR100 user manual

Endress+Hauser
Endress+Hauser Micropilot FMR62 technical information

WEBTEC
WEBTEC HPM110 operating instructions

iSystem
iSystem Infineon AGBT user manual