ISOMAG MS2410 Operating and maintenance instructions

ELECTROMAGNETIC FLOW METER
“FULL BORE” SENSORS MODEL MS2410
INSTALLATION MANUAL
Authorization
n. 1035

Pag. 2 ESENS_FULLBORE_R01_MS2410_IS
INDEX
INTRODUCTION___________________________________________ 3
START UP AND MAINTENANCE OF THE INSTRUMENTS _____________ 3
SAFETY _________________________________________________ 4
GENERAL INFORMATION ON THE SENSORS INSTALLATION _________ 5
ELECTRICAL CONNECTIONS OF SENSOR TO CONVERTER ___________ 6
GROUNDING INSTRUCTIONS ________________________________ 6
OVERALL DIMENSIONS _____________________________________ 7
THREADED CONNECTIONS __________________________________ 7
CLAMP CONNECTIONS ______________________________________ 8
INSPECTION SCREWS ______________________________________ 9
CONFORMITY DECLARATION____ ERRORE. IL SEGNALIBRO NON È DEFINITO.
ADDRESSES _____________________________________________ 12

Pag. 3 ESENS_FULLBORE_R01_MS2410_IS
INTRODUCTION
-This manual is integral part of the product. Read carefully the instructions
contained since it contains important indications for the safety of use and
of maintenance.
-The technical information and the relative products of this manual could be
modified without any previous notice.
-The flow meter must be used for the use it has been built for. The improper
use, possible tampering of the instrument or parts of it and substitutions of
any components not original, makes the warranty to decay automatically.
-The manufacturer is considered responsible only if the instrument is used in
its original configuration and setting.
-The flowmeter makes measures of liquids with conductivity greater than
5µS/cm; it consists of a sensor (described in this manual) and a converter,
for it see the manual provided.
-If the sensor is supplied in compact version to the converter, consider the
operating temperatures more restrictive, otherwise refer to the respective
manuals (page 5).
-When transporting, unpacking and handling the flowmeter, be careful and
care.
-In the case of prolonged storage and of transport, use and store in the
original container in a dry place, do not place more than 3 packs one above
the other. It is possible pallets storage and transport (in case of wooden
crates do not place one above the other).
-For the cleaning of the device use only a damp cloth, and for the
maintenance/repairs, contact the customer service.
-For the disposal of the device and of the packaging make strict reference to
the regulations.
-It is forbidden the reproduction of the present manual and of possible
software supplied with the instrument.
START UP AND MAINTENANCE OF THE INSTRUMENTS
-Before starting up the instrument, always make a sure connection to
ground as suitable to page 6.
-Verify periodically: the cables integrity, the tightening of the sealing
elements (cable glands, covers, etc.), the mechanical fixing of the
instrument on the pipe or on the wall stand.

Pag. 4 ESENS_FULLBORE_R01_MS2410_IS
SAFETY
Before using the instrument, always make a sure connection to
the ground
Avoid any attempt to repair the instrument. If the instrument is
not functioning properly, please call the nearest assistance
service
Pay maximum attention during the operations
ATTENTION !!!
DANGER !!!

Pag. 5 ESENS_FULLBORE_R01_MS2410_IS
Before install the sensor locate the direction of the liquid in the piping
The sign of the flow rate is positive, when the flow direction is from –to + as
printed on the tag plate.
If after the installation, for plant request becomes necessary reverse the sign of the
flow, it is enough reverse the sign of the coefficient KA
GENERAL INFORMATION ON THE SENSORS INSTALLATION
ANTIVIBRATION
3 X DN
2 X DN
LONG PIPE
FITTING SENSOR
FITTING PIPE
NUT
FITTING SENSOR
FITTING PIPE
NUT
In vertical installations an ascending flow is preferable. For vertical installations with descending flow direction contact
the manufacturer
For installations in long pipe lines, please use anti vibration joints
Avoid a partially empty pipe, during operation the pipe must be either completely full of liquid
or completely empty
Install the sensor away from bends and hydraulic accessories
Avoid positioning fittings by tigthening the clamps.
The manufacturer recommend to clean the instruments before use
Flow direction

Pag. 6 ESENS_FULLBORE_R01_MS2410_IS
For correct operation of the meter is NECESSARY that the sensor and the liquid
are equipotential, so ALWAYS connect the sensor and converter to ground:
GROUNDING INSTRUCTIONS
ELECTRICAL CONNECTIONS OF SENSOR TO CONVERTER
(CONNECTIONS TO CONVERTER: SEE PROPER MANUAL)

Pag. 7 ESENS_FULLBORE_R01_MS2410_IS
A
L
D100
FITTINGS
FITTINGS
DN
100
33
THREADED CONNECTIONS
NB :With DIN connection use suitable gasket for cleaning in place (CIP) application
SMS 1146 connection is only suitable for cleaning out of place (COP)
DIN 11851
DIMENSIONS
mm (inches)
DN
3
(1/8")
6
(1/4)
10
(3/8)
15
(1/2")
20
(3/4")
25
(1")
32
(1"1/4)
40
(1"1/2)
50
(2")
65
(2"1/2)
80
(3")
100
(4”)
A
77
(3.03)
77
(3.03)
77
(3.03)
77
(3.03)
77
(3.03)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
L
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
180
(7.09)
180
(7.09)
180
(7.09)
180
(7.09)
180
(7.09)
200
(7.87)
200
(7.87)
D
76
(3)
76
(3)
76
(3)
76
(3)
76
(3)
76
(3)
89
(3.50)
89
(3.50)
114
(4.49)
140
(5.51)
140
(5.51)
168
(6.61)
CONNECTIONS
DN 10
DN 10
DN 10
DN 15
DN 20
DN25
DN 32
DN 40
DN 50
DN 65
DN 80
DN
100
SMS-1146
DIMENSIONS mm
(inches)
10
(3/8)
15
(1/2")
20
(3/4")
25
(1")
40
(1"1/2)
50
(2")
65
(2"1/2)
80
(3")
100
(4")
A
77
(3.03)
77
(3.03)
77
(3.03)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
L
128
(5.04)
128
(5.04)
128
(5.04)
180
(7.09)
180
(7.09)
180
(7.09)
180
(7.09)
200
(7.87)
200
(7.87)
D
76
(3)
76
(3)
76
(3)
76
(3)
89
(3.50)
114
(4.49)
140
(5.51)
140
(5.51)
168
(6.61)
CONNECTIONS
DN 25
DN 25
DN 25
DN25
DN 38
DN 51
DN 63
DN 76
DN 104
OVERALL DIMENSIONS

Pag. 8 ESENS_FULLBORE_R01_MS2410_IS
FITTINGS
FITTINGS
I ( Ø INTERNAL FITTING )
33
100
A
L
D100
F
CLAMP CONNECTIONS
CLAMP ISO 2852
DIMENSIONS mm
(inches)
DN
3
(1/8")
6
(1/4)
10
(3/8)
15
(1/2")
20
(3/4")
25
(1")
40
(1"1/2)
50
(2")
65
(2"1/2)
80
(3")
100
(4")
A
77
(3.03)
77
(3.03)
77
(3.03)
77
(3.03)
77
(3.03)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
L
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
180
(7.09)
180
(7.09)
180
(7.09)
180
(7.09)
200
(7.87)
200
(7.87)
D
76
(3)
76
(3)
76
(3)
76
(3)
76
(3)
76
(3)
89
(3.50)
114
(4.49)
140
(5.51)
140
(5.51)
168
(6.61)
I
12.7
(0.5)
12.7
(0.5)
12.7
(0.5)
17.2
(0.68)
21.3
(0.84)
22.6
(0.89)
35.6
(1.40)
48.6
(1.91)
60.3
(2.37)
72.9
(2.87)
97.6
(3.84)
F
34
(1.34)
34
(1.34)
34
(1.34)
34
(1.34)
34
(1.34)
50.5
(1.99)
50.5
(1.99)
64
(2.52)
77.5
(3.05)
91
(3.58)
119
(4.69)
CLAMP BS 4825 Part3
DIMENSIONS mm
(inches)
DN
3
(1/8")
6
(1/4)
10
(3/8)
15
(1/2")
20
(3/4")
25
(1")
40
(1"1/2)
50
(2")
65
(2"1/2)
80
(3")
100
(4")
A
77
(3.03)
77
(3.03)
77
(3.03)
77
(3.03)
77
(3.03)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
100
(3.94)
L
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
128
(5.04)
180
(7.09)
180
(7.09)
180
(7.09)
180
(7.09)
200
(7.87)
200
(7.87)
D
76
(3)
76
(3)
76
(3)
76
(3)
76
(3)
76
(3)
89
(3.50)
114
(4.49)
140
(5.51)
140
(5.51)
168
(6.61)
I
9.5
(0.37)
9.5
(0.37)
9.5
(0.37)
15.85
(0.62)
22.2
(0.87)
22.2
(0.87)
34.9
(1.37)
47.6
(1.87)
60.3
(2.37)
73
(2.87)
97.6
(3.84)
F
25.4
(1)
25.4
(1)
25.4
(1)
25.4
(1)
50.5
(1.99)
50.5
(1.99)
50.5
(1.99)
64
(2.52)
77.5
(3.05)
91
(3.58)
119
(4.69)

Pag. 9 ESENS_FULLBORE_R01_MS2410_IS
Inspection
screw
3°
INSPECTION SCREWS
Verify periodically the sensor’s seals integrity:
with piping full of liquid, unscrew the
Inspection screws (see drawing aside) and
verify the total absence of liquid from
inspection hole!
After the above operation, REMEMBER to
close again the holes.
In case of leakage contact immediately our
Customer Service.
When flow meter is installed horizontally, ensure minimum angle of 3° for self-draining purposes

Pag. 10 ESENS_FULLBORE_R01_MS2410_IS
At the end of its lifetime, this product shall be disposed of in full compliance with the
environmental regulations of the state in which it is located.

Pag. 11 ESENS_FULLBORE_R01_MS2410_IS

ADDRESSES
Isoil Industria spa
Head office
20092 Cinisello Balsamo (MI) Italy
27, via F.lli Gracchi
Phone +39-02-66027.1
Fax +39-02-6123202
E-mail: [email protected]
Web: www.isoil.com
Service
Isoil Industria spa
20092 Cinisello Balsamo (MI) Italy
27, via F.lli Gracchi
Phone +39-02-66027.1
Fax +39-02-6123202
E-mail: isomagservice@isoil.it
Table of contents
Other ISOMAG Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

Electro-Sensors
Electro-Sensors SG1000RA user manual

Spectra
Spectra Precision HD150 user manual

Omega
Omega VSHYe Series Installation and operation manual

Schiltknecht Messtechnik
Schiltknecht Messtechnik MiniAir20 Operating instruction

Triplett
Triplett FOX instruction manual

Camax
Camax Powercom3 user manual

Siemens
Siemens sitrans PROBE LU Quick start manual

WAGNER
WAGNER RAPID RH user manual

National Instruments
National Instruments PXIe-5603 Getting started guide

NI
NI PXIe-4137 SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION

Gemu
Gemu 1211 Installation, operating and maintenance instructions

Milwaukee
Milwaukee MW13 user manual