Lumissil Microsystems – www.lumissil.com 1
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
IS31SE5118A EvB User
Manual
Revision: C
Publication: June 28, 2023
Copyright © 2020~2023 Integrated Silicon Solution, Inc. All rights reserved. ISSI reserves the right to make
changes to this specification and its products at any time without notice. ISSI assumes no liability arising out of
the application or use of any information, products or services described herein. Customers are advised to
obtain the latest version of this device specification before relying on any published information and before
placing orders for products.
Integrated Silicon Solution, Inc. does not recommend the use of any of its products in life support applications
where the failure or malfunction of the product can reasonably be expected to cause failure of the life support
system or to significantly affect its safety or effectiveness. Products are not authorized for use in such
applications unless Integrated Silicon Solution, Inc. receives written assurance to its satisfaction, that:
a.) the risk of injury or damage has been minimized;
b.) the user assumes all such risks; and
c.) potential liability of Integrated Silicon Solution, Inc is adequately protected under the circumstances
Lumissil Microsystems – www.lumissil.com 2
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
1. HARDWARE ENVIRONMENT
1.1 Evaluation Board (EvB)
Figure 1-1: Photo of IS31SE5118A Evaluation Board
Figure 1-2: Photo of Standard 6 Touch Key Board
Lumissil Microsystems – www.lumissil.com 3
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
System Block Diagram
Figure 1-3: IS31SE5118A Evaluation Board Connection Block Diagram
1.2 Schematic of Evaluation Board
Figure 1-4: Schematic of IS31SE5118A Evaluation Board
Title
Size Document Number Rev
Date: Sheet of
1.0
IS31SE5118A EBGUI
A3
1 1Thursday, May 11, 2023
+5V
SDA
GND
SCL
RSTN
IRQ
GND
MicroUSB(+5V DC POWER SUPPLY)
4P DIP Switch
IRQ
Shield
P06
Function Option
RSTN
1 and 2 → Shield (by SGND)
2 and 3 → Shield (by P06)
3 and 4 → IRQ (P06)
4 and 5 → IRQ (P13)
Float2
Float1
SCREW HOLE is Floating
Float4
Float3
VMCU
BZ_POW
P13_LED
P13
P13_LED
1 and 2 → LED
2 and 3 → BZ_POW
SCREW HOLE
Note: Power Consumption = (12V - 5V) * (0.1A) = 0.7W
Thermal Resistance(TO-252) = 16℃/W
Junction Temperature = (0.7 * 16) + 25 = 44.2℃
P03
MCU_VSS
MCU ISP INTERFACE / I2C INTERFACE
RESET
VMCU
TouchKey CREF P00
RSTN
TDO P04_SDA
P05_SCL
MCU_VSS
RSTN
P05_SCL
TCK
P04_SDA
TDI
CS
P12
P13
P03
P00
VDDC
P11
P07
P06
P02
P01
VMCU
P10
Input Voltage Maximum is 25V
VMCU
VMCU
MCU
MCU_VSS VDDC
BZ_POW
NC
BZ_POW
BUZZER Output
BUZZER / MELODY
0Ror Bead
TCK
TDO
VMCU
Linear Regulator (DC+12V to DC+5V @100mA)
IRQ
P00
P01
CS
TDI P03
P04_SDA
MCU WRITER INTERFACE
POWER SUPPLY JACK (+12V)
P07
Shield
P02
P01
P10
P12
P11P05_SCL
10X2_2.54mm Pin Header10X2_2.54mm Pin Header
RSTN
P13
P04_SDA
ACCESSORY BOARD CONNECTOR
MCU_VSS
10X2_2.54mm Female Header
R28 0R
R0805
D3
LED_Green
LED-MR03
R19 470R R0603
R2 20R
R2512
J8
PH7X1_2.54
1
2
3
4
5
6
7
R9 1K
R0603
R24 470R R0603
C3
10uF/50V
C1210
R25 470R R0603
P2
MUYF-051T-4BH81
MicroUSB_5PP
VBUS 1
D- 2
D+ 3
ID 4
GND 5
S
8
S
7
S
6S9
C9 2.2nF
C0603
J4
CONN IDC_2.54 5X2
CONN_IDC_5X2_2.54
1 2
3 4
5 6
7 8
910
C11
4.7uF
C0603
J2
CONN10X2_2.54
20
19
18
17
16
15
14
13
12
11
1
2
3
4
5
6
7
8
9
10
R10 470R R0603
C2
10uF/25V
C1206
R12 470R R0603
C7
10uF/25V
C1206
R16
NC
R0603
JT2
Chassis_Drill_3.5mm
R23 4.7K
R0603
J10
PH5X1_2.54
1
2
3
4
5
R1 20R
R2512
R7 NC
R0603
JT4
Chassis_Drill_3.5mm
R3
1K
R0603
Q1
QP_MMBT3906
C12
0.1uF
C0603
S1
SW PUSHBUTTON
2
13
4
SW1
SW_SPDT
SW_SPDT
2 3
JT1
Chassis_Drill_3.5mm
C4
10uF/50V
C1210
+C8
22uF/16V
D6 D_CD4148WP
1206
J6
PH3X1_2.54
1
2
3
SW2
SW DIP-4/SM
U1 LDO_AS7805
TO-252
GND
2
VIN
1VOUT 3
+C15
47uF/16V
D2
DS_SS24
DO-214AA
C10
0.1uF
C0603
C13
4.7uF
C0603
R8 0R
R0805
R27
10K
R0603
D5
TVS_SMBJ24A
DO-214AA(SMB)
C14
0.1uF
C0603
R5
1M
R0603
R4 0R
R0603
C5
0.1uF
C0805
JT3
Chassis_Drill_3.5mm
R13 4.7K
R0603R17 470R R0603R15
4.7K
R0603
D7 LED_Red
LED0805
R26
10K
R0603
R6 NC
R0603
D4
DS_SS24
DO-214AA
R20 470R R0603
R14
4.7K
R0603
C6
0.1uF
C0805
D1 DS_ZHCS400AP1
HEADER1
Q2
QN_MMBT3904
+C1
220uF/35V
EC-10
U2
IS31SE5118A_TSSOP16
VDD
1
RSTN
2
P05/SCL
3
P04/SDA
4
P03
5
P13
6
P12
7
P11
8P10 9
P02 10
P01 11
P07 12
P06 13
P00 14
VDDC 15
VSS 16
J1
CONN10X2_2.54
20
19
18
17
16
15
14
13
12
11
1
2
3
4
5
6
7
8
9
10
R22 4.7K
R0603
R21
100R
R0603
R18 1K
R0805
P1
DC_PowerJack
PowerJack_DC005
1
2
3
J3
CONN10X2_2.54
20
19
18
17
16
15
14
13
12
11
1
2
3
4
5
6
7
8
9
10
+
-
BZ1
OBO-1212C-A2
Buzzer
Q3
QN_MMBT3904
F1 Fuse
R11
10K
R0603
+12V
S_GND
+5V
+12V
P_GND
+5V
+5V
S_GND
S_GND
S_GND
S_GND
S_GNDP_GND
S_GNDS_GNDS_GND
P_GND
+5V
P_GND
+5V
S_GND
P_GND P_GND
BZ_GND
+12V
+5V
BZ_GNDS_GND
S_GND
BZ_GND
P_GND
S_GND
Lumissil Microsystems – www.lumissil.com 4
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Figure 1-5: Schematic of Standard 6 Touch Key Board
SCREW HOLE
ACCESSORY Board
(6 * TouchKey & 1 * Shield)
Float1
Float2
Float3
Float4
SCREW HOLE is Floating
J1
CONN10X2_2.54
20
19
18
17
16
15
14
13
12
11
1
2
3
4
5
6
7
8
9
10
Title
Size Document Number Rev
Date: Sheet of
1.0
MCU 6 Touch Keys Board
A4
1 1Thursday, May 11, 2023
B4 BTN4
TouchKey_Pad_Input
B1 BTN1
TouchKey_Pad_Input
JT1
Chassis_Drill_3.5mm
SH1 TouchKey_Pad
Shield
B2 BTN2
TouchKey_Pad_Input
JT2
Chassis_Drill_3.5mm
JT3
Chassis_Drill_3.5mm
B0 BTN0
TouchKey_Pad_Input
B3 BTN3
TouchKey_Pad_Input
JT4
Chassis_Drill_3.5mm
B5 BTN5
TouchKey_Pad_Input
Lumissil Microsystems – www.lumissil.com 5
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Figure 1-6: Key setting of Standard 6 Touch Key Board
1.3 ORDERING INFORMATION
Table 1: Ordering Information
Part No.
Temperature Range
Package
IS31SE5118A-ZNLS3-EBGUI
-40°C ~ +105°C
TSSOP-16, Lead-free
For pricing, delivery, and ordering information, please contact LUMISSIL’s marketing and sales team at
https://www.lumissil.com/company/office-locations or (408) 969-6600.
Lumissil Microsystems – www.lumissil.com 6
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
2. SOFTWARE SUPPORT
2.1 Software Requirements
Before starting up SE5118A Touch Key GUI software, it is required that the PC be installed with the EzISP
USB driver and related files (for example Microsoft Framework and C++ library). Users can unzip file
EzISP_V3.3.3.zip and use the setup file for installation. But this installation needs Windows login users with
administrator privileges.
Figure 2-1: Photo of EzISP Board
Windows Software Requirements:
EzISP tool supports Win XP, Vista, Windows 7, Windows 8, Windows 10, and Windows 11. It is required
that the Windows-based PC be installed with Microsoft .NET Framework 3.5, Microsoft .NET Framework
4.8, Microsoft Visual C++ 2008, and Silicon Labs’ USB driver version 6.7.2.0. After running EzISP setup
version 3.3.8 or a later version, Windows will ask the user to install Microsoft .Net Framework or Microsoft
Visual C++ 2008 if this PC was not installed with the redistributable packages. Users can follow the pop-
up instructions to finish the installation.
Users might need up to seven steps to finish the EzISP installation and configuration after installation for
normal operation.
Step 1: For customers who have installed EzISP setup version earlier than 3.3.8 with Silicon Labs’ USB
driver version 3.2.0.0, USB driver version 3.2.0.0 needs to be uninstalled as the four steps in the
below figure before installing the new EzISP setup version 3.3.8.
Lumissil Microsystems – www.lumissil.com 7
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Step 2: Install EzISP setup program. After the installation is done and EzISP is run, users might get
below pop-up message and please update with the newer BIOS as Step 3 ~ Step 7.
Users can check whether the Silicon Labs’ USB driver version 6.7.2.0 is correctly installed
or not as the two steps in the below figure.
Step 3: Go to “Tool(T)”–> “Update EzISP BIOS(U)”
Lumissil Microsystems – www.lumissil.com 8
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Step 4: Below figure pops out. Click “Open” button.
Step 5: Click “Browse” button.
Lumissil Microsystems – www.lumissil.com 9
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Step 6: Below figure pops out. Choose the default pop-out hex file under C:\Program Files
(x86)\Lumissil\EzISP\Release\EzISP bios &bootloader and click “Open” button.
Step 7: Follow the four steps in the below figure to load Bootloader. Reset the EzISP
device to start operation.
Lumissil Microsystems – www.lumissil.com 10
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
2.2 Start up the GUI with EvB
Three-step setup (Please refer to Figure 1-3 IS31SE5118A Evaluation Board Connection Block
Diagram.)
1. Connect USB cable between the USB port of the EzISP Board and the USB port of the PC.
2. Connect a 10-pin 2x5 Socket-Socket 2.54mm IDC cable from the connector on the EzISP Board
to the connector S1 of the IS31SE5118A Evaluation Board.
3. Execute SE5118A Touch Key GUI program (file name: MC10_SE5118A_GUI_rev3.0.exe).
Figure 2-2: Connection of IS31SE5118A Evaluation Board and EzISP Board
Table 2: I2C Slave Address Definition
Lumissil Microsystems – www.lumissil.com 11
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
I2C Slave Address*
Write Command
Read Command
0x78
0x79
* I2C Slave Address: 7-bit Address + 1 bit(R/W)
2.3 Upgrade Boot Code and Standard Code
This section can help users to upgrade Boot code and Standard code of SE5118A EvB. In case, Boot
code or Standard code of SE5118A EvB is ruined, users can follow the below 4 steps to program the
code.
Step 1: Turn the DIP switch SW2 ON
Turn the DIP switch SW2 1/2/3/4 to ON as the highlighted red rectangles in the below SE5118A EvB
figure.
Step 2: Program boot code
Program boot code “ MC10B1C_IS31CS8975-ZNLS2-TR_revD.hex” to IS31SE5118A EvB.
a. Execute the EzISP Tool
b. Select “Writer” and “IS31SE5118A” from drop-down menu
c. Click “Load” to load boot code file “MC10B1C_IS31CS8975-ZNLS2-TR_revD.hex”
d. Click “Auto Run”
e. Close the EzISP program
Lumissil Microsystems – www.lumissil.com 12
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Step3: Turn DIP switch SW2 off
Turn the DIP switch SW2 1/2/3/4 to OFF as the highlighted red rectangles in the below SE5118A EvB
figure.
Lumissil Microsystems – www.lumissil.com 13
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Step 4: Program Device Standard Code/Firmware
Program Device Firmware into SE5118A EvB
a. Run SE5118A GUI Tool V3.0
b. Click the Program Device FW from the File drop-down menu
c. Click “Select” to open firmware file “MC10_SE5118A_STD_revC.hex”, and then click “Program”
d. Close Update Code window and click “Connect” button
e. Connect Status will be displayed as "Connect" with a green box and this GUI will display the current
firmware version after clicking the “Connect” button.
Lumissil Microsystems – www.lumissil.com 14
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Lumissil Microsystems – www.lumissil.com 15
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
3. SE5118A TOUCH KEY GUI INTERFACE
3.1 Before Use
IS31SE5118A EvB board should have standard code/firmware inside, but users can follow below step 1 to
step 3 to program firmware to start evaluation of this board in case there is no standard code firmware
inside.
Step 1. Click the Program Device FW from the File drop-down menu.
Step 2. Click Select to open the firmware file then click Program. If Configuration File is not selected,
then the default settings will be programmed. Users can click “Export Configuration to File” to
save the current configuration and choose the preferred configuration file before performing
“Program Device FW”.
Step 3. Close the “Update Code”window and click the “Connect” button if the “Connect” status box is
not green. (If IS31SE5118A EvB kit is not connected to the PC before this software is run,
“Connect” status box will be red after running this software.)
Figure 3-1: Program Device FW Before Use
Lumissil Microsystems – www.lumissil.com 16
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Figure 3-2: Firmware update code
If the GUI looks small, the following method can improve high-DPI support for the GUI.
Users need to find file MC10_SE5118A_GUI_rev3.0.exe, right-click on it and select Properties.
Figure 3-3: Set GUI program Properties
Lumissil Microsystems – www.lumissil.com 17
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Go to the Compatibility tab and click Change high DPI settings. Select Override high DPI scaling
behavior. Scaling performed by: System or System (Enhanced) and click OK.
Restart the GUI to see if there is an improvement.
Figure 3-4: Choose High DPI settings
3.2 Connect Status
Before running Touch Key GUI tool, please make sure SW2 switch of the IS31SE5118A EvB is all OFF.
Users can refer to Section 1.1 Evaluation Board to find SW2.
The I2C slave address is fixed at 0x78, as shown in Figure 3-5: GUI Connect Status Shows Disconnect
with IS31SE5118A EvB connected to PC via EzISP board. If the user finds the “Device” status in red,
please try to re-connect the devices connection with PC USB port, then close and run Touch Key GUI tool
again. If the “Device” status still shows red, it might be because the device’s boot code is not correctly
burned. If the “Connect” status is in yellow color after trying to re-connect devices connection with PC
USB port and running Touch Key GUI tool again, it might be caused by standard code not being correctly
burned.
Lumissil Microsystems – www.lumissil.com 18
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
The “Connect”status box might be red and users cannot change any setting if IS31SE5118A EvB and
EzISP board are not connected to the PC before running the GUI software. Users can click the “Connect”
button and the “Connect” status will turn green.
Figure 3-5: GUI Connect Status Shows Disconnect
As shown in Figure 3.6 below, the “Connect”status box will be green and GUI displays current firmware
version.
Figure 3.6: GUI Connect Status Shows Connect
Lumissil Microsystems – www.lumissil.com 19
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
3.3 Export/Import Configuration File
As shown in Figure 3-7 below, Export Configuration to File is used to export the configuration of
IS31SE5118A and save in a file. By exporting the configuration, we can save the parameters settings in the
GUI to a file (The default file name is an excel file “register values” and users can define file name for
version control). It also simultaneously creates a BIN file in the same folder and the file can be used for
manufacture.
Import Configuration from File is used to import the configuration setting from the preferred IS31SE5118A
GUI settings file into the device. Click Apply to apply the parameters to the device.
Figure 3-7: GUI Import/Export Options
3.4 Update Configuration to Flash
As shown in Figure 3-8 below, users can write the parameters settings in the GUI into the flash of the
IS31SE5118A chip. After clicking the Update Configuration to Flash from the File drop-down menu,
writing configuration settings to the flash can be completed in about 4 seconds.
The embedded Flash Memory has the capability to hold the saved data even if the power is off. When
IS31SE5118A is powered on again, the parameters previously written to the flash will become the default
values.
Lumissil Microsystems – www.lumissil.com 20
Rev. C, 06/28/2023
IS31SE5118A EvB User’s Manual
Figure 3-8: GUI Update Configuration to Flash
3.5 Restore Factory Setting to Device
As shown in Figure 3-9 below, after clicking the Restore Factory Setting to Device from the File drop-
down menu, writing factory default parameters to the flash can be completed in about 4 seconds.
Need to click “Connect”button to refresh parameters in the GUI.
Figure 3-9: Restore Factory Setting to Device

Popular Microcontroller manuals by other brands

ST STM32H5 Nucleo-144 user manual

ST

ST STM32H5 Nucleo-144 user manual

Fujitsu F2MC-16LX Series Hardware manual

Fujitsu

Fujitsu F2MC-16LX Series Hardware manual

DIGITAL-LOGIC SM800/900DK Technical  user's manual

DIGITAL-LOGIC

DIGITAL-LOGIC SM800/900DK Technical user's manual

KANDA STK300 manual

KANDA

KANDA STK300 manual

Xsens MTi  600 Series user manual

Xsens

Xsens MTi 600 Series user manual

Atmel MC320 Getting started guide

Atmel

Atmel MC320 Getting started guide

Luminus DK-236 Series manual

Luminus

Luminus DK-236 Series manual

ST UM2334 Getting started

ST

ST UM2334 Getting started

Winbond W742C813 manual

Winbond

Winbond W742C813 manual

Texas Instruments MSP430x4xx Family user guide

Texas Instruments

Texas Instruments MSP430x4xx Family user guide

onsemi AXM0F343 user manual

onsemi

onsemi AXM0F343 user manual

Intrinsyc Open-Q 660 mSOM user guide

Intrinsyc

Intrinsyc Open-Q 660 mSOM user guide

National Instruments sbRIO-9651 quick start guide

National Instruments

National Instruments sbRIO-9651 quick start guide

Microchip Technology ATSAMR30M18A datasheet

Microchip Technology

Microchip Technology ATSAMR30M18A datasheet

Microchip Technology PD-95-10GC Series user guide

Microchip Technology

Microchip Technology PD-95-10GC Series user guide

Texas Instruments ADC12DJ3200CVAL user guide

Texas Instruments

Texas Instruments ADC12DJ3200CVAL user guide

Samsung S3P80C5 user manual

Samsung

Samsung S3P80C5 user manual

Velleman KSR10/USBN user manual

Velleman

Velleman KSR10/USBN user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.