ITC T-6350 User manual

350/500/650-WATT AMPLIFIER
T-6500
T-6350
T-6650
OPERATION MANUAL
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
PUBLIC ADDRESS SYSTEM
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
350-WATT AMPLIFIER
T-6350
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
500-WATT AMPLIFIER
T-6500
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
650-WATT AMPLIFIER
T-6650

2
TABLE OF CONTENTS
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel .................................................................................................................6
4.2 Rear Panel ..................................................................................................................7
4.3 Rear Panel(24V) ..........................................................................................................8
5. CONNECTIONS
5.1 Speaker Connections ...................................................................................................9
5.2 XLR Connections .........................................................................................................9
6. APPLICATIONS .....................................................................................................10
7. .................................................................................................11
8. SPECIFICATIONS ................................................................................................12
9. DIMENSIONAL DIAGRAM ..................................................................................13
BLOCK DIAGRAM

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
1. SAFETY PRECAUTIONS
3

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
ITC
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
SAFETY PRECAUTIONS
4
Due to product upgrades, while some of the features and specification in the user manual does not
match the actual functions, sorry for any inconvenience and thanks for your kind understanding!

3. FEATURES
Heavy-duty public address power amplifiers deliver clean audio power from 350 to 650 watts RMS with less
than 0.5% distortion. Rugged and overbuilt to provide years of reliable service they are equipped with
torroridal transformers, extensive heat-sinking, forced fan cooling and protective circuits against short-circuit,
clipping and over-temperature.
2. GENERAL DESCRIPTION
1. Rated outputs from 350W to 500W and 650W.
2. 100V/70V lconstant voltage outputs and 4~16 ohms constant resistance outputs.
3. Commercial-grade torroidal transformers produce high performance audio on a wide range of
frequencies with minimal noise and high fidelity, even at high volume.
4. Intelligent limiter can reduce excess signal.
5. Reliable protection against overload, short circuit, and power fluctuation for optimum reliability.
6. Heat sinks and fan protect against overheating, protecting the amplifiers working life.
7. Rubber feet and rack mount ears-may be placed on tables or installed in rack mount cabinets.
5

ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
4. NOMENCLATURE AND FUNCTIONS
1. POWER SWITCH
On top of the opening Power, Press the end, power shut down
2. VOLUME
Channel volume control
3. TEMP
Temperature Indicator
4. PROT
Protection indicator LED Prot lit when over heat,short circuit and overloading.
5. CLIP
Clip lit when max wattage output & output signal distortion.
6. SIGNAL
Signal indicator LED, When lit input signal is detected.
7. POWER
Power Indicator
4.1 T-6350-6500-6650 FRONT PANEL
12
3
4
56
6
7

COM 4-16 70V 100V
OUTPUTS
COMCOM
GND
LIFT
INPUTS LINK
INPUTS LINK
12
3
XLR BAL
1-GND
2-HOT+
3-COLD-
NOMENCLATUREAND FUCTIONS
8. AC POWER INPUT
9. COMMON SPEAKER OUTPUT
Connectors for 4~16 ohms or 70V and 100V speaker
10. LINE INPUT (XLR)
Music signal input balance
11. LINE INPUT (6.35TRS)
Balanced or unbalanced input music signal (unbalanced input, use of non-equilibrium
6.35TRS jack)
12. LINK OUTPUT (6.35TRS)
Balanced or unbalanced output music signal (unbalanced output, use of non-equilibrium 6.35TRS jack)
13. LINE CASCADE OUTPUT (CORLEONE SOCKET)
XLR, output signal of power amplifier
14. FAN
Equipment, exhaust vents, equipment work properly, you must wrap the hole can not have any object
covered, to avoid overheating protection
15. GROUND LIFTER
Earth line ground or lift switch. Enable the switch to "GND" position when one unit is used, disable the switch
"LIFT" when several units are used to avoid noise caused by several earth line grounded.
811 12 149
15
10
7
4.2 T-6350-6500-6650 REAR PANEL
13

GND
LIFT
INPUTS LINK
INPUTS LINK
1122
33
XLR BAL
1-GND
2-HOT+
3-COLD-
COM 4-16 70V 100V
OUTPUTS
NOMENCLATUREAND FUCTIONS
8
813 14 15911
16
4.3 T-6350-6500-6650 REAR PANEL+24V
10 12
8. AC POWER INPUT
9. SPARED (BATTERY) POWER INTERFACE.
10. COMMON SPEAKER OUTPUT
Connectors for 4~16 ohms or 70V and 100V speaker
11. LINE INPUT (XLR)
Music signal input balance
12. LINE INPUT (6.35TRS)
Balanced or unbalanced input music signal (unbalanced input, use of non-equilibrium
6.35TRS jack)
13. LINK OUTPUT (6.35TRS)
Balanced or unbalanced output music signal (unbalanced output, use of non-equilibrium 6.35TRS jack)
14. LINE CASCADE OUTPUT (CORLEONE SOCKET)
XLR, output signal of power amplifier
15. FAN
Equipment, exhaust vents, equipment work properly, you must wrap the hole can not have any object
covered, to avoid overheating protection
16. GROUND LIFTER
Earth line ground or lift switch. Enable the switch to "GND" position when one unit is used, disable the switch
"LIFT" when several units are used to avoid noise caused by several earth line grounded.
BATT SUPPLY
24V 30A

5. CONNECTIONS
100V LINE
100V
(T-6350)
(T-6500)
(T-6650)
14
9.8
7.5
70V LINE
5.1 SPEAKER CONNECTIONS
4-16
4~16
70V/
4~16
(T-6350)
(T-6500)
(T-6650)
28.6
20
15.4
COM
70V 100V 4~16 COM
70V 100V 4~16 COM
70V
5.2 XLR CONNECTIONS
9

COM 4-16 70V 100V
OUTPUTS
COMCOM
GND
LIFT
INPUTS LINK
INPUTS LINK
1122
33
XLR BAL
1-GND
2-HOT+
3-COLD-
6. APPLICATIONS
REAR PANEL CONNECTIONS
AUX2 OUT
AUX1
MIC2 MIC3
MUTE EMC INPUT
MIC2 MIC3
LINE INPUT
OUTPUT
COM 4-16 70V 100V
AMPLIFIER
REC LINE 10 LINE 9 LINE 8 LINE 7
LEFT
RIGHT
MIC INPUTS MIC/LINE INPUTS
MAX 9.9W P.T.T 12
3
4
5
6
7
89
10
INSIDEAC/DC
FUSE 230VAC DC POWER
24V MAX 0.6A
2 1
3
7
4
5
2
4
2
GND
PRIORITY
CHIME
LEDPWR
MICINPUT
1
3
5
6
7
1
3
6
CHIME
REMOTE
2--OUTPUTS--1
MIXER AMPLIFIER
SPEAKERS
10

7. BLOCK DIAGRAM
PROTECT
Output
Level meter
100V
70V
4~16 Ohms
COM
INPUTS EB EB
INPUTS
LINK
230V
0V
~220-240 /50/60Hz
11

8. SPECIFICATIONS
MODEL
RATED POWER OUTPUT
SPEAKER OUTPUTS
PROTECTION
INPUT SENSITIVITY
FREQUENCY RESPONSE
S/N RATIO
T.H.D
CONTROLS
INDICATORS
T-6650
650W
4~16 ,70V/100V
775mV/0dB
50Hz~18KHz
Better than 105dB
Less than 1% at 1KHz, 1/3 rated power
Power switch, volume control
Power, clipping , Signal , protect and high
AC fuse, short-circuit , clipping and high temperature
DIMENSION(mm)
NET WEIGHT
GROSS WEIGHT
484X408X132
POWER CONSUMPTION
POWER REQUIREMENTS
T-6350
350W
17Kg
14.5Kg
500W
21Kg
18.5Kg
950W
T-6500
500W
19Kg
16.5Kg
720W
12
~220-240V 50/60Hz

100
Over
100
Over
Over
100
9. DIMENSIONAL DIAGRAM
UNIT :mm
6
128
128
25
383
377
132
138
436
484
UNIT:mm
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
13
COM 4-16 70V 100V
OUTPUTS
COMCOM
GND
LIFT
INPUTS LINK
INPUTS LINK
1122
33
XLR BAL
1-GND
2-HOT+
3-COLD-

100
Over
100
Over
Over
100
DIMENSIONAL DIAGRAM
UNIT :mm
6
128 128
25
383
377
132
138
436
484
UNIT:mm
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
ON
OFF
POWER
CLIP
TEMP
VOLUME
PROT
5
0
1
2
3
4 6
7
8
9
10
SIGNAL
14
GND
LIFT
INPUTS LINK
INPUTS LINK
1122
33
XLR BAL
1-GND
2-HOT+
3-COLD-
COM 4-16 70V 100V
OUTPUTS
BATT SUPPLY
24V 30A

PUBLIC ADDRESS SYSTEM
PUBLIC ADDRESS SYSTEM
VersionV0.4
This manual suits for next models
2
Table of contents
Other ITC Amplifier manuals