ITC TS-4200PD User manual

OPERATION MANUAL
Please follow the instructions in this manual to obtain the optimum results from this unit.
We also recommend that you keep this manual handy for future reference.
PUBLIC ADDRESS SYSTEM
TS-4200PD/4350PD/4500PD
PROFESSIONAL POWER AMPLIFIER
PRO
CLP
SIG
POWER
CHB
MIN MAX
TS-4350PD
PROFESSIONAL POWER AMPLIFIER
ON OFF
CHC
MIN MAX CHD
MIN MAX
CHA
MIN MAX
cha chb chc chd

TABLE OF CONTENTS
2
1. SAFETY PRECAUTIONS .......................................................................................3
2. GENERAL DESCRIPTION ....................................................................................5
3. FEATURES ...............................................................................................................5
4. NOMENCLATURE AND FUNCTIONS
4.1 Front Panel ..............................................................................................................6
4.2 Rear Panel............................................................................................................... 7
5. OPERATION ILLUSTRATION ................................................................................8
6. ............................................................................................10
7. APPLICATIONS ..................................................................................................... 11
8.BLOCK DIAGRAM .................................................................................................12
9.SPECIFICATIONS ................................................................................................. 13
10.DIMENSIONAL DIAGRAM ................................................................................. 14
TROUBLESHOOTING

Be sure to read the instructions in this section carefully before use.
Make sure to observe the instructions in this manual as the conventions of safety symbols and messages
regarded as very important precautions are included.
We also recommend you keep this instruction manual handy for future reference.
Safety Symbol and Message Conventions
Safety symbols and messages described below are used in this manual to prevent bodily injury and property
damage which could result from mishandling. Before operating your product, read this manual first and
understand the safety symbols and messages so you are thoroughly aware of the potential safety
Indicates a potentially hazardous situation which, if mishandled, could
result in death or serious personal injury.
Indicates a potentially hazardous situation which, if mishandled, could
result in moderate or minor personal injury, and/or property damage.
When Installing the Unit
Do not expose the unit to rain or an environment
where it may be splashed by water or other liquids,
as doing so may result in fire or electric shock.
Use the unit only with the voltage specified on the
unit. Using a voltage higher than that which is
specified may result in fire or electric shock.
Do not cut, kink, otherwise damage nor modify the
power supply cord. In addition, avoid using the
power cord in close proximity to heaters, and never
place heavy objects -- including the unit itself -- on
the power cord, as doing so may result in fire or
electric shock.
Be sure to replace the unit's terminal cover after
connection completion. Because high voltage is
applied to the speaker terminals, never touch these
terminals to avoid electric shock.
Be sure to ground to the safety ground (earth)
terminal to avoid electric shock. Never ground to a
gas pipe as a catastrophic disaster may result.
Avoid installing or mounting the unit in unstable
locations, such as on a rickety table or a slanted
surface. Doing so may result in the unit falling
down, causing personal injury and/or property
damage.
When the Unit is in Use
Should the following irregularity be found during
use, immediately switch off the power, disconnect
the power supply plug from the AC outlet and
contact your nearest dealer. Make no further
attempt to operate the unit in this condition as this
may cause fire or electric shock.
If you detect smoke or a strange smell coming
from the unit.
If water or any metallic object gets into the unit
If the unit falls, or the unit case breaks
If the power supply cord is damaged (exposure of
the core, disconnection, etc.)
If it is malfunctioning (no tone sounds.)
To prevent a fire or electric shock, never open nor
remove the unit case as there are high voltage
components inside the unit. Refer all servicing to
your nearest dealer.
ITC
ITC
Do not place cups, bowls, or other containers of
liquid or metallic objects on top of the unit. If they
accidentally spill into the unit, this may cause a fire
or electric shock.
Do not insert nor drop metallic objects or
flammable materials in the ventilation slots of the
unit's cover, as this may result in fire or electric
shock.
1. SAFETY PRECAUTIONS
3

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in
the electrical installation of the building.
When Installing the Unit
Never plug in nor remove the power supply plug
with wet hands, as doing so may cause electric
shock.
When unplugging the power supply cord, be sure
to grasp the power supply plug; never pull on the
cord itself. Operating the unit with a damaged
power supply cord may cause a fire or electric
shock.
When moving the unit, be sure to remove its power
supply cord from the wall outlet. Moving the unit
with the power cord connected to the outlet may
cause damage to the power cord, resulting in fire or
electric shock. When removing the power cord, be
sure to hold its plug to pull.
Do not block the ventilation slots in the unit's cover.
Doing so may cause heat to build up inside the unit
and result in fire.
Avoid installing the unit in humid or dusty locations,
in locations exposed to the direct sunlight, near the
heaters, or in locations generating sooty smoke or
steam as doing otherwise may result in fire or
electric shock.
When the Unit is in Use
Do not place heavy objects on the unit as this may
cause it to fall or break which may result in
personal injury and/or property damage. In
addition, the object itself may fall off and cause
injury and/or damage.
Make sure that the volume control is set to
minimum position before power is switched on.
Loud noise produced at high volume when power is
switched on can impair hearing.
Do not operate the unit for an extended period of
time with the sound distorting. This is an indication
of a malfunction, which in turn can cause heat to
generate and result in a fire.
Contact your dealer as to the cleaning. If dust
is allowed to accumulate in the unit over a long
period of time, a fire or damage to the unit may
result.
ITC
If dust accumulates on the power supply plug or in
the wall AC outlet, a fire may result. Clean it
periodically. In addition, insert the plug in the wall
outlet securely.
Switch off the power, and unplug the power supply
plug from the AC outlet for safety purposes when
cleaning or leaving the unit unused for 10 days or
more. Doing otherwise may cause a fire or electric
shock.
SAFETY PRECAUTIONS
4
Due to product upgrades, while some of the features and specification in the user manual does not
match the actual functions, sorry for any inconvenience and thanks for your kind understanding!

It is a high-efficiency four-channel professional power amplifier with a combination of high-performance
switching power supply and class D power amplifier; Support four balanced / unbalanced inputs and
a high-fidelity circuit design with extremely low distortion THD+N<0.02% @ 1W. It adopts 2U standard
cabinet design, with high efficiency, light weight and beautiful appearance. Ideal for medium and large-
scale theaters, outdoor performances, theaters, stadiums, clubs, night clubs, entertainment venues,
bars, rental, auditorium, banquet halls and concert, etc.
2. GENERAL DESCRIPTION
1. Adopting the latest class-D power amplifier design scheme, with small distortion and high efficiency;
2. The power supply adopts switching power supply, which has high efficiency; it is soft-started at startup
to prevent large current from being absorbed into the power grid and interfering with other power-
consuming equipment.
3. Effectively suppress power supply harmonics and meet EU green power standards.
4. Intelligent peak clipping limiter can control power module and speaker system work within safe range;
5. It is more convenient for users with different demands to adopt simple interfaces, namely standard
XLR + TRS1/4" composite input interfaces.
6. There are three levels of input sensitivity optional in two-channel power amplifier, which can easily
accept wide range signal source input.
7. Stereo or bridge operation mode is optional to adaptation for different occasions.
8. Input grounding pin grounding and suspension control switch, which has noise suppression.
9. With overvoltage protection, undervoltage protection, over temperature and pressure limit, over
temperature shutdown, overcurrent voltage limit, overcurrent shutdown, DC protection, output short
circuit protection, temperature control fan, power amplifier frequency synchronization, PWM frequency
synchronization, etc.
10. Built-in recoverable unique cut-off switch.
11. The detachable structure of the panel cleans the dustproof cotton by itself.
5
3. FEATURES

4. NOMENCLATURE AND FUNCTIONS
6
4.1 FRONT PANEL
PRO
CLP
SIG
POWER
CHB
MIN MAX
PROFESSIONAL POWER AMPLIFIER
ON OFF
CHC
MIN MAX CHD
MIN MAX
CHA
MIN MAX
cha chb chc chd
41 2 5
3
678
1. Installation positioning holes (19-inch cabinets);
2. Air grid;
3. The volume control knob of the CHA channel controls the output volume of the channel. Rotate
the volume clockwise to increase the volume and vice versa. (Note: CHB/CHC/CHD channels
are similar).
4. Power switch;
5. Power status indicator;
6. CLP— Clipping indicator. When the (yellow) indicator light on the machine is lit by a signal, the
output signal is distorted at this time, indicating that the input signal is too large. Please reduce
the input signal.
7. PRO—Protection indicator. The first 3 seconds of booting is the machine startup process. At this
time (red) the protection light is on. If the self-test of the whole machine is normal, it start the whole
machine after 3 seconds and turn off the light. If it is in a protected state for a long time after power
on, the whole machine is faulty. Please contact your dealer.
8. SIG—Signal indicator, when the machine is normally input, the (green) indicator is on. When the
machine fails or the signal is not input correctly, the (green) indicator does not light up.
NOTE:
To prevent the fan holes from being blocked and the machine from overheating, remove the dust
filter on the panel regularly for cleaning.
Cleaning method: first remove the four screws on the panel, take out the dust filter to clean it. After
the filter is cleaned and dried, install it back to the original position.

7
4. NOMENCLATURE AND FUNCTIONS
4.2 REAR PANEL
9. AC power input;
10. CHC / CHD channel output port, please use the port labeled "BRIDGE" when bridging;
11. CHA / CHB channel output port, please use the port labeled "BRIDGE" when bridging;
12. Cooling fan;
13. CHC / CHD channel unbalanced signal ground control switch;
14. CHC / CHD channel input port. In the BRIDGE mode, only the CHC input port is valid.
15. CHC / CHD channel sensitivity switch;
16. CHA / CHB channel unbalanced signal ground control switch;
17. CHA / CHB channel input port. In BRIDGE mode, only CHA input port is valid.
18. CHA / CHB channel sensitivity switch;
19. CHA / CHB channel bridge / stereo / parallel transfer switch;
① STEREO mode: Channels A and B work independently. The input signal of channel A is output
through A output port. And the input signal of channel B is output through the B output port.
②PARALLEL mode: The input signal is output through the output ports of channel A and channel B,
and the volume of channels A and B can be adjusted independently.
③BRIDGE mode: The input signal of channel A is output from the BRIDGE output port. You can only
adjust the volume through the volume control knob of channel A. And the knob of CHB channel has
no such effect.
20. CHC / CHD channel bridge / stereo / parallel transfer switch (refer to the 19 item for details);
21. Overload protection switch.
BREAKER
AC INPUT
2500W
~220V 50Hz
LIFT
GND
BRIDGE
STEREO
PARALLEL
1.44V
1V
0.775V
CHB INPUT
CHA INPUT
INPUTS
CHA OUT
BRIDGE
(MIN 8 )
CHB OUT
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
LIFT
GND
BRIDGE
STEREO
PARALLEL
1.44V
1V
0.775V
CHD INPUT
CHC INPUT
CHC OUT
BRIDGE
(MIN 8 )
CHD OUT
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
9
21
10 12
11 14
13 15 1617 18
19
20

8
5. OPERATION ILLUSTRATION
2.Connect external devices
①Please ensure that the equipment and all equipment will be connected are powered off.
②Using the corresponding cable to connect this equipment and other external equipment.
:
3.Connect the power line and turn it on:
①Please make sure that the power switch of equipment and its connected equipment are
turned off (in the OFF position).
②Turn the volume knob to the left
③Connect the supplied power line to the AC IN interface
④Plug the power line into the applicable socket
⑤Turn on the connected equipment (CD player, etc.), and then turn on the equipment.
Note:
1.Before powering on, please check and make sure there is no problem with the cable and connection.
2.When you turn off the system, turn off the equipment, and then turn off the connected equipment.
1. Connect the speakers:
①In the operating mode of STEREO and
PARALLEL, the speaker connection is as
shown below:
②In BRIDGE's operating mode, the speaker
connection is as shown below:
CHA OUT
CHB OUT
BRIDGE
(MIN 8 )
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
BRIDGE
STEREO
PARALLEL
BRIDGE
STEREO
PARALLEL
SPK+ TO PDS1+或
SPK- TO NEQ1-或NEQ2-
PDS2+ SPK+ TO PDS1+或PDS2+
SPK- TO NEQ1-或NEQ2-
CHA CHB
CHA OUT
CHB OUT
BRIDGE
(MIN 8 )
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
BRIDGE
STEREO
PARALLEL
SPK+ TO PDS1+或PDS2+
SPK- TO NEQ1-或NEQ2-
CHA
Note:
1. Before connecting the speakers, please make sure that the equipment is powered off. In the
case of power on, may have the risk of electric shock.
2. Please make sure there are no applied load to the speaker cables.
3. During the installation of speakers, please make sure that the sum of the rated input power
of the speakers to be connected is less than rated power of equipment.

9
5. OPERATION ILLUSTRATION
Note:
1.Turn off the power switch,Please wait about 5 seconds before turning on again.Continuous rapid
turning on and off the power switch,it will lead to equipment failure.
2.Even the switch is in the off status, there will be a little current in equipment. If it won’t use the
equipment in a long time, please unplug the power cord from the wall AC socket.
4.
1.Turning the volume knob to the left,Connect the microphone and microphone input interface.
2.Turning the volume knob in the right position.
3.Facing the microphone and Speak loudly, turn the volume knob to the right, until the output signal
no longer distortion.If input is high but output is low voice, and then increase the volume by using
the volume knob.If the speaker volume is very high, then reduce the volume by using the volume
knob.
Microphone using:
5.Shutdown the system:
1.Turning the volume knob to the left until the minimum position.
2.Turning off the panel power switch of the professional power amplifier, at 0ff.In turn shutoff
processor equipment and audio source equipment.

10
6. TROUBLESHOOTING
Failure phenomena Failure cause
1. Power switch is not opened
1Power line is cut off
2. The protection function of the equipment is
not activated
.
2. All lines are connected, but there is
no sound.
1. The power switch is not opened or the power
plug is bad contacted.
2. The fuse is burnt
3. The volume knob is not opened or turned down
to a extra low level
4. There is no audio signal input
5. There is short-circuit in the speaker line.
3. The sound suddenly disappears in
normal status.
1. The equipment is in very high temperature to
make it into protection status.
2. The connection wire is bad contact.
4. Low sound
The equipment is set to be low impedance
connection, but the speakers connected is
with high impedance.
5. Sound is distorted The input level of Mic or external equipment
is too high

7. APPLICATIONS
REAR PANEL CONNECTIONS
11
OPEN
CLOSE
PLAY STOP NEXTPREVIOUS
ON
OFF
POWER
CD player / MP3 player and other audio source equipment
BREAKER
AC INPUT
2500W
~220V 50Hz
LIFT
GND
BRIDGE
STEREO
PARALLEL
1.44V
1V
0.775V
CHB INPUT
CHA INPUT
INPUTS
CHA OUT
BRIDGE
(MIN 8 )
CHB OUT
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
LIFT
GND
BRIDGE
STEREO
PARALLEL
1.44V
1V
0.775V
CHD INPUT
CHC INPUT
CHC OUT
BRIDGE
(MIN 8 )
CHD OUT
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
Channel D Channel B
Channel C Channel A
Handheld wireless microphone
Mixer
Professional audio processor
1 1+2 2
OUTPUT OUTPUT OUTPUT
1 1+2 2 1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
OUTPUT
1 1+2 2
SIG SIG SIG SIG SIG SIG SIG SIG SIG SIG
LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL LEVEL
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
0
2
3
456
7
8
10 0
19
2
3
456
7
8
10 0
19
0
0 0
HIGH
LOW
HIGH
+3 0 -3
-8
-13
MODE MODE MODE MODE MODE MODE MODE MODE MODE
P.T.T 1
CHIME
MASTER
1
LOW
MASTER
2
PRIORITY2
PRIORITY3
PRIORITY4
LINE
MIC
POWER
MASTER VOLUME
1
2
MASTER VOLUME
MIC/LINE 2 MIC/LINE 3 MIC/LINE 4 MIC/LINE 5 MIC/LINE 6 MIC/LINE 7 MIC/LINE 8 MIC/LINE 9 MIC/LINE 10
ON
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
LINE
MIC
ON
1 2 3
Preamplifier
MIC

12
8. BLOCK DIAGRAM
XLR/TRS
2*200W/2*350W/2*500W
Fan control
Power amplifier module
Amplifier output
LEVEL
1
2
3
T
G
S
R
1
2
3
T
G
S
R
1
2
3
T
G
S
R
1
2
3
T
G
S
R
CHA INPUT
CHB INPUT
CHC INPUT
CHD INPUT
Balanced & Unbalanced Conversion
Sensitivity conversion
Bridge/ Stereo/ parallel
Front control
Indicator light
2*200W/2*350W/2*500W
Power amplifier module
Bridge output

13
9. SPECIFICATIONS
Output power
Stereo / parallel
Stereo / parallel
Bridge
Connecting interfaces
Voltage gain
Input sensitivity
Input impedance
Frequency response (under 1W power)
THD + N (under @ 1/8 power)
SNR(A-weighted)
Resolution (@ 1KHz)
Protection method
Indicator light
Cooling method
Powered supply
Maximum power consumption
Weight
Dimension (LxWxH)
(20-20KHz/THD≤1%)
8Ω×4
4Ω×4
8Ω×2
(@1KHz)
Damping coefficient (@ 1KHz)
TS-4200PD
105W×4
200W×4
420W×2
32dB
0.775V/1V/1.44V
20-20KHz/+0/-2dB
≤0.05%
≥95dB
≥200@ 8 ohms
≥80dB
~220-240V 50-60Hz
1000W
8.8Kg
484x350x88 mm
XLR, TRS interfaces
10K Ω unbalanced, 20KΩ balanced
Over current/DC/short circuit protection
Power, protection, distortion
Fan cooling
TS-4350PD
190W×4
350W×4
750W×2
34.4dB
TS-4500PD
350W×4
500W×4
1000W×2
36.2dB
1800W
9Kg
2600W
9.2Kg

10. DIMENSIONAL DIAGRAM
14
UNIT:mm
UNIT:mm
100
Over
100
Over
Over
100
PRO
CLP
SIG
POWER
CHB
MIN MAX
TS-4500PD
PROFESSIONAL POWER AMPLIFIER
ON OFF
CHC
MIN MAX CHD
MIN MAX
CHA
MIN MAX
cha chb chc chd
88
94
484
84
436
6
84
25 325
PRO
CLP
SIG
POWER
CHB
MIN MAX
TS-4500PD
PROFESSIONAL POWER AMPLIFIER
ON OFF
CHC
MIN MAX CHD
MIN MAX
CHA
MIN MAX
cha chb chc chd
BREAKER
AC INPUT
2500W
~220V 50Hz
LIFT
GND
BRIDGE
STEREO
PARALLEL
1.44V
1V
0.775V
CHB INPUT
CHA INPUT
INPUTS
CHA OUT
BRIDGE
(MIN 8 )
CHB OUT
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-
LIFT
GND
BRIDGE
STEREO
PARALLEL
1.44V
1V
0.775V
CHD INPUT
CHC INPUT
CHC OUT
BRIDGE
(MIN 8 )
CHD OUT
Ω
2+ 2-
PDS NEQ
1+ 1-
PDS NEQ
2+ 2-
PDS NEQ
1+ 1-
2+ 2-
PDS NEQ
1+ 1-

PUBLIC ADDRESS SYSTEM
VersionV0.1
This manual suits for next models
2
Table of contents
Other ITC Amplifier manuals