Balancing the air flow
In a balanced ventilation system the volume of air coming
from outside equals the amount of air discharged from the
home. The outside air suction fan, therefore, turns faster
when the frost protection is triggered. Thus, the volume of
air coming from outside remains the same as the amount
of air discharged from the home. The total volume of air
intake increases proportionally with the volume of air
taken in from the home by the frost valve. Opening the
frost valve is not sufficient when the outside temperature
is even lower. The intake fan will turn more slowly and,
after some time, the discharge ventilator will turn faster.
The air, therefore, remains above freezing. This results in
a temporary imbalance of the ventilation (the volume of air
coming from outside is no longer equal to the amount of
air discharged from the home). When the outside
temperature increases, the unit automatically resets the
fans to the initial values. The ventilation is thus once again
balanced.
Electronic components
The electronic components are important parts of the unit.
The electronic components control the operation of the
unit when you set the mode switch. The motor is set to the
speed that ensures the desired ventilation. The electronic
components consist of a basic printed circuit board and an
optional radio frequency module. This can be used to
extend the ventilation unit with radio frequency operation.
The user should not touch the electronic components.
These components may be live.
Bypass
The Itho heat recovery unit HRU ECO 4 is delivered as
standard with a 100% bypass valve. This valve is completely
integrated in the unit and ensures that, if required, the
fresh outside air flows directly to the air supply system
instead of through the heat exchanger. In this case there is
no heat transfer between the warmer discharge air from
the home and the colder intake air that is drawn into the
home. The fresh outside air is blown directly into the
home. This is definitely an advantage in the summer, when
the outside air is often cooler than the air within the home.
Frost protection
The unit includes, as standard, frost protection. This
protection ensures that the unit does not freeze during the
winter. The frost protection consists of a unique frost valve
integrated at the top of the unit. The frost protection is fully
automatic.
Frost protection operation
In the heat recovery unit the fresh (colder) outside air
is partly heated by the air discharged from the home.
The exchange of heat takes place when both air flows are
led through the heat exchanger. The discharged air may be
cooled to a temperature very near freezing by the cold air
entering the unit from outside. In this case, the unit will
regularly open the frost valve and take in warm air from
the home. This warm air is mixed with the cold air that is
taken in from outside. The temperature of the intake air is,
therefore, higher and the discharge air in the heat
exchanger will also be safely above freezing. The unit
will thus not freeze.
4 Bypass and frost protection