ITK CS3-1C5EU-FPS User manual

1
Òåõíè÷åñêèå äàííûå
Îñíîâíûå ñâåäåíèÿ îá èçäåëèè
Ðàçú¸ì òèïà RJ-45 FPS ëåãêîé îêîíöîâêè òîâàðíîãî çíàêà ITK (äàëåå –
ðàçú¸ì) ïðåäíàçíà÷åí äëÿ êîììóòàöèè íåýêðàíèðîâàííûõ êàáåëåé âèòàÿ
ïàðà êàòåãîðèè 5å èëè 6 ñ îáîðóäîâàíèåì êîìïüþòåðíûõ ñåòåé ïåðåäà÷è
äàííûõ.
Ðàçú¸ì ñîîòâåòñòâóþò òðåáîâàíèÿì òåõíè÷åñêîãî ðåãëàìåíòà
ÒÐ ÅÀÝÑ 037/2016.
Ãàáàðèòíûå ðàçìåðû ðàçúåìà ïðåäñòàâëåíû íà ðèñóíêå 1.
Êîìïëåêòíîñòü
Êîìïëåêò ïîñòàâêè ïðåäñòàâëåí â òàáëèöå 2.
Òåõíè÷åñêèå õàðàêòåðèñòèêè ðàçú¸ìà ïðèâåäåíû â òàáëèöå 1.
Ìåðû áåçîïàñíîñòè
Ðàáîòû ïî ìîíòàæó äîëæíû ïðîèçâîäèòüñÿ êâàëèôèöèðîâàííûì
ïåðñîíàëîì.
- óäàëèòü âåðõíèé çàùèòíûé ñëîé êàáåëÿ íà äëèíå 12,5 ìì. Äëÿ ýòîãî
èñïîëüçîâàòü èíñòðóìåíò äëÿ çà÷èñòêè è îáðåçêè êàáåëÿ ñâÿçè.
Íåîáõîäèìî ñäåëàòü îäèí ïîëíûé îáîðîò âîêðóã êàáåëÿ è ñíÿòü
ïîäðåçàííóþ ÷àñòü èçîëÿöèè;
Ìîíòàæ ðàçú¸ìà ïðîèçâîäèòñÿ íà êàáåëü ñâÿçè ñîîòâåòñòâóþùåé
êàòåãîðèè.
Äëÿ ìîíòàæà ðàçú¸ìà íà êàáåëü ñâÿçè íåîáõîäèìî ïðîäåëàòü
ñëåäóþùèå äåéñòâèÿ:
- ðàñïëåñòè ñâèòûå ïàðû ïðîâîäíèêîâ. Ïàðû ðàñïëåòàþòñÿ âïëîòü äî
Ïðàâèëà ìîíòàæà è ýêñïëóàòàöèè
Ìîíòàæ ðàçúåìà äîëæåí îñóùåñòâëÿòüñÿ ïðè òåìïåðàòóðå îò 0 ºÑ äî
ïëþñ 40 ºÑ.
ÐÀÇÚ¨Ì ÒÈÏÀ RJ-45 FPS ËÅÃÊÎÉ ÎÊÎÍÖÎÂÊÈ
Êðàòêîå ðóêîâîäñòâî ïî ýêñïëóàòàöèè
RU

Òðàíñïîðòèðîâàíèå èçäåëèé äîïóñêàåòñÿ â óïàêîâêå èçãîòîâèòåëÿ
ëþáûì âèäîì êðûòîãî òðàíñïîðòà, îáåñïå÷èâàþùèì ïðåäîõðàíåíèå
óïàêîâàííîãî èçäåëèÿ îò ìåõàíè÷åñêèõ ïîâðåæäåíèé, ïðè òåìïåðàòóðå îò
0 ºÑ äî ïëþñ 40 ºÑ.
Òðàíñïîðòèðîâàíèå, õðàíåíèå è óòèëèçàöèÿ
Ðàçú¸ì ÿâëÿåòñÿ îäíîðàçîâûì èçäåëèåì è ïîâòîðíîé îïðåññîâêå
íå ïîäëåæèò.
êðàÿ îáîëî÷êè êàáåëÿ. Çà÷èùàòü èçîëÿöèþ ïðîâîäÿùåé æèëû íå òðåáóåòñÿ;
Óòèëèçèðîâàòü ðàçú¸ì ïóòåì ïåðåäà÷è â ñïåöèàëèçèðîâàííûå
ïðåäïðèÿòèÿ ïî ïåðåðàáîòêå âòîðè÷íîãî ñûðüÿ.
Èçíîñîñòîéêîñòü ðàçúåìà – 750 öèêëîâ ïîäêëþ÷åíèÿ.
Ñðîê ñëóæáû ðàçúåìà – íå ìåíåå 10 ëåò. Ïî èñòå÷åíèè ñðîêà ñëóæáû
Õðàíåíèå èçäåëèé îñóùåñòâëÿåòñÿ â óïàêîâêå èçãîòîâèòåëÿ â çàêðûòûõ
ïîìåùåíèÿõ ñ åñòåñòâåííîé âåíòèëÿöèåé ïðè òåìïåðàòóðå îêðóæàþùåé
ñðåäû îò 0 ºÑ äî ïëþñ 40 ºÑ. Âåðõíåå çíà÷åíèå îòíîñèòåëüíîé âëàæíîñòè
âîçäóõà 98 % ïðè 25 ºÑ.
Òåêóùèé ðåìîíò
- ðàñïîëîæèòü ðàñïëåò¸ííûå ïàðû òàêèì îáðàçîì, ÷òîáû
ñôîðìèðîâàëñÿ ïëîñêèé ñëîé èç ïàðàëëåëüíî ðàñïîëîæåííûõ ïðîâîäíèêîâ
â ïîðÿäêå öâåòîâ, ñîîòâåòñòâóþùåì âûáðàííîé ñõåìå çàäåëêè êàáåëÿ;
- âñòàâèòü ðàçúåì ñ êàáåëåì â óãëóáëåíèå, ðàñïîëîæåííîå íà ðàáî÷åé
ïîâåðõíîñòè îáæèìíîãî èíñòðóìåíòà, è íàæàòèåì íà ðó÷êè èíñòðóìåíòà
îáæàòü êàáåëü. Ïðè ýòîì âûñòóïàþùèå èç êîðïóñà ðàçú¸ìà êîíòàêòû
èíñòðóìåíò îáðåæåò.
- äëÿ ñîåäèíåíèÿ ïðîâîäíèêîâ ñ íîæàìè ðàçú¸ìà èñïîëüçîâàòü
ñïåöèàëüíûé èíñòðóìåíò äëÿ îáæèìà êàáåëÿ - êðèìïåð FPS;
- ïîìåñòèòü ïðîâîäíèêè â ðàçúåì íàñêâîçü. Îáîëî÷êà êàáåëÿ äîëæíà
çàõîäèòü â êîðïóñ ðàçú¸ìà, ïî êðàéíåé ìåðå, íà ðàññòîÿíèå 5 ìì;
Òåõíè÷åñêîå îáñëóæèâàíèå
ÂÍÈÌÀÍÈÅ
Ðàçúåì íå òðåáóåò îáñëóæèâàíèÿ â ïðîöåññå ýêñïëóàòàöèè.
Ðàçúåì ÿâëÿåòñÿ íåðåìîíòîïðèãîäíûì èçäåëèåì è â ñëó÷àå âûõîäà èç
ñòðîÿ ïîñëå èñòå÷åíèÿ ãàðàíòèéíîãî ñðîêà ïîäëåæèò óòèëèçàöèè.
Ñðîê ñëóæáû è ãàðàíòèè èçãîòîâèòåëÿ
2

Ãàðàíòèéíûé ñðîê ýêñïëóàòàöèè èçäåëèÿ – 1 ãîä ñî äíÿ ïðîäàæè ïðè
óñëîâèè ñîáëþäåíèÿ ïîòðåáèòåëåì ïðàâèë ýêñïëóàòàöèè,
òðàíñïîðòèðîâàíèÿ è õðàíåíèÿ.
èçäåëèå óòèëèçèðîâàòü.
RJ-45 FPS type connector with light termination of the ITK trademark
(hereinafter referred to as connector) is designed for switching unshielded
twisted-pair cables of 5e or 6 category with Computer Data Communications
Equipment.
Completeness of set
Connector is mounted on a communication cable of the corresponding
category.
- remove the cable sheath for a length of 12,5 mm. To do this, use the
communication cable stripping and cutting tool. It is necessary to make one full
turn around the cable and remove the undercut part of the insulation;
Basic product data
To mount the connector on the communication cable, do the following:
The scope of delivery is shown in the table 2.
Specifications of connector are given in the table 1.
Overall dimensions of connector are shown in the figure 1.
Safety precautions
Works on the installation of connector should be carried out by qualified
personnel.
Technical data
Mounting of connector should be carried out at temperatures from 0 ºÑ to
plus 40 ºÑ.
Rules for installation and operation
RJ-45 FPS TYPE CONNECTOR WITH LIGHT TERMINATION
EN
3

- arrange the unbraided pairs in such a way that a flat layer of parallel
conductors is formed in the order of colors corresponding to the selected cable
termination scheme;
- unbraid twisted pairs of conductors. Pairs are unbraided up to the edge of
the cable sheath. It is not required to strip the insulation of the conductive core;
- insert the conductors through the connector. The cable sheath should
extend into the connector housing at least 5 mm.;
- to connect the conductors with the connector knives, use a special tool for
crimping the cable - the FPS crimper;
- insert the connector with the cable into the recess located on the working
surface of the crimping tool and crimp the cable by pressing the tool handles. In
this case, the contacts protruding from the connector housing will be cut off by
the tool.
Warranty period of operation of the product is 1 year from the date of sale, if
the consumer observes the rules for operation, transportation and storage.
Maintenance
Connector is non-repairable products and in case of failure after the warranty
period has expired, they should be disposed of.
Storage of products is carried out in the manufacturer's package in enclosed
spaces with natural ventilation at an ambient temperature of 0 ºC to plus 40 ºC.
The upper value of the relative air humidity is 98 % at 25 ºÑ.
ATTENTION
Endurance of connector – 750 connection cycles.
Connector is disposable products and cannot be re-crimped.
The service life of connector is at least 10 years. Dispose the product at the
end of its service life.
Current maintenance
Connector do not require maintenance during operation.
Transportation of products is allowed in the manufacturer's package by any
type of covered transport that protects the packed product from mechanical
damage at temperatures from 0 ºC to plus 40 ºC.
Transportation, storage and disposal
Dispose the connector by transferring to specialized recycling companies.
Service life and manufacturer's warranties
4

Íàèìåíîâàíèå ïàðàìåòðà / Parameter denomination
Çíà÷åíèå äëÿ ðàçúåìîâ / Value for connector
CS3-1C5EU-FPS
CS3-1C06U-FPS
Ìàêñèìàëüíûé òîê, À / Maximum current, À
1,5
Íîìèíàëüíîå ðàáî÷åå íàïðÿæåíèå,  / Rated voltage, V
48
Êàòåãîðèÿ/Category
5å
6
Ïîëîñà ïðîïóñêàíèÿ, ÌÃö / Bandwidth, MHz
1-100
1-250
Òèï ðàçú¸ìîâ / Connector type
RJ-45
Âèä êîíôèãóðàöèè êîíòàêòîâ / Type of contact
arrangement
8P8C
Ýêðàíèðîâàíèå/Shielding
Íåò / There is not
Ïîäêëþ÷àåìûé êàáåëü è ïðîâîäíèêè / Connected cable
and conductors
Êðóãëûé êàáåëü, îäíîïðîâîëî÷íûå æèëû / Round cable,
solid conductors
Äèàìåòð ïîäêëþ÷àåìûõ ïðîâîäíèêîâ, ìì / Diameter of
connected conductors, mm
0,41-0,57 ìì (23-26 AWG)
Ìàòåðèàë êîðïóñà / Case material
Ïîëèêàðáîíàò, íå ïîääåðæèâàþùèé ãîðåíèå ïî
Ul94 V-0 è UL94V-2 / Flame retardant polycarbonate
according to UL94 V-0 and UL94V-2
Ìàòåðèàë êîíòàêòîâ ðàçúåìîâ / Connector contact
material
Ôîñôîðèñòàÿ áðîíçà ñ íèêåëåâûì ïîêðûòèåì / Nickel
plated phosphor bronze
Òîëùèíà ïîêðûòèÿ êîíòàêòîâ çîëîòîì, ìêì / Thickness of
gold coating of contacts, µm
15,0 (15µ)
Êîíòàêòíîå ñîïðîòèâëåíèå êîíòàêòîâ RJ, ìÎì / Contact
resistance of RJ contacts, mOhm
20
Êîíòàêòíîå ñîïðîòèâëåíèå êîíòàêòîâ IDC, ìÎì / Contact
resistance of IDC contacts, mOhm
2,5
Ïîääåðæêà òåõíîëîãèè PoE / PoE support
4 êëàññ (30 Âò íà ïîðò) / 4th class (30 W per port)
Ñîïðîòèâëåíèå èçîëÿöèè, ÌÎì / Insulation resistance,
MOhm
500
Äèýëåêòðè÷åñêàÿ ïðî÷íîñòü èçîëÿöèè,  / Dielectric
strength of insulation, V
1000 (ïðè 60 Ãö) / 1000 (at 60 Hz)
Äèàïàçîí ðàáî÷èõ òåìïåðàòóð, ºÑ / Operating temperature
range, ºÑ
Îò ìèíóñ 10 äî ïëþñ 60 / From minus 10 to plus 60
Òàáëèöà / Table 1
5

6
Íàèìåíîâàíèå / Denomination
Êîëè÷åñòâî, øò. / Qty., pcs.
Èçäåëèå / Product
100
Ðèñóíîê / Figure 1
Òàáëèöà / Table 2
21,4
22,5
7,9
6,6
13,0
3,2
6,1
11,7
Èçäàíèå/Version 3
This manual suits for next models
1