ITS Telecom CelluLine CGW-T Assembly instructions

CelluLine
CGW-T GSM Gateway
Installation and Programming
Manual


CelluLine CGW-T
Installation and Programming Manual
Release 4, Revision 3, April 2004

NOTICE
This manual describes the CelluLine CGW-T GSM Gateway.
Additional copies of this manual may be obtained from ITS. No part of this document may be
reproduced or transmitted in any form, by any means (electronic, photocopying, recording, or
otherwise) without the prior written permission of ITS.
ITS reserves the right to modify the hardware and software described in the manual without
prior notice. However, changes made to the hardware or software described does not
necessarily render this publication invalid.
WARRANTY
In the event that the product proves to be defective in workmanship or materials within a
period of one year from date of shipment, ITS shall repair or replace the product at its
discretion. Transportation will be the responsibility of the dealer/distributor. Under no
circumstances shall ITS be liable for consequential or special damages, loss of revenue
or user/dealer expenses arising out of or in connection with the use or performance of
the product, whether based on contract, tort, or any other legal agreement.
The following shall void the above warranty: malfunctions resulting from fire, accident,
neglect, abuse, or acts of God; use of improper electrical power; or repair of, tampering with
or alteration of the product by anyone other than ITS authorized personnel.

Table of Contents
1Introduction ................................................................................................1
1.1 Main Features................................................................................................2
1.2 Physical Description......................................................................................3
2Pre-Installation ...........................................................................................5
3Installation...................................................................................................7
3.1 SIM Card Insertion in the CelluLine CGW-T Unit ......................................7
3.2 CelluLine CGW-T Installation......................................................................8
4LCD Status Indicators and Diagnostics ...................................................9
4.1 LCD Status Indicators...................................................................................9
4.2 Diagnostics..................................................................................................12
5DTMF Programming ...............................................................................13
6Technical Data ..........................................................................................19
7CelluLine CGW-T Accessories................................................................21


CelluLine CGW-T Installation and Programming Manual 1
1 Introduction
ITS is introducing the GSM Gateway – CelluLine CGW-T, a GSM cost reduction tool.
In a period, in which companies focus on cost reduction (without influencing the integrity of
the company), the CelluLine CGW-T will play an important role. The unit directly connects
your PBX to the GSM network, eliminating the excessive interconnection fees, thus cutting
your telephone costs significantly.
The CGW-T is connected to the analog trunk interface of the PBX. The
Automatic Route Select Table (ARS) in the PBX defines which calls will
be automatically routed via the CGW-T to the pre-defined GSM network.
In doing so, the CGW-T gateway reduces the company’s telephone costs.
Installation of the CGW-T does not require special skills. Simply insert
the SIM card, connect the unit to the PBX trunk interface, attach the
antenna and power supply and your CGW-T can immediately start saving
money for you. The unit has an LCD display, which shows the GSM
operator’s name, the signal strength and other useful call progress
information.
A number of additional parameters for the CGW-T, such as Output Audio
Volume level setting, Conversion time-out and Restricted Digits, can be
programmed via DTMF.

2 CelluLine CGW-T Installation and Programming Manual
1.1 Main Features
The following is a list of Main Features of the CelluLine CGW-T GSM Gateway:
• Integrated dual-band GSM module (900/1800, 850/1900 MHz)
• Built-in LCD
• Signal strength indicator
• Cellular operator name indicator
• Operational status
• DTMF programming
• Call Barring (Toll Restriction)
• Conversation Time-Out
• Reverse polarity signaling support
• Audio Volume control
• Roaming Control
• CLIR
• Supports DTMF dialing
• Line interface, 2-wire (RJ-11 connector)
• Plug & Play installation
• High voice quality
• Maintenance free

CelluLine CGW-T Installation and Programming Manual 3
1.2 Physical Description
The Front panel of the CGW-T contains:
1. The antenna connector
2. The LCD
3. The Trunk connector
4. The Power Supply connector
The Bottom to the CGW-T contains:
5. The SIM release lever
6. The SIM card tray
(1)
(2)
(3)
(4)
(5)
(6)


CelluLine CGW-T Installation and Programming Manual 5
2 Pre-Installation
The CelluLine CGW-T unit contains a GSM engine. It therefore needs a SIM card from the
local GSM network provider. Its registration to the GSM operator is similar to the registration
of a mobile GSM phone.
The PIN & PUK code request must be disabled. Is this not the case, use any GSM mobile
phone to modify the SIM card or contact the local GSM Service Center.
Recommendation
We recommend disabling all call forwarding modes (in the events of busy, absence,
unavailability, etc.) and Call Waiting from the GSM operator, before installing the SIM card.


CelluLine CGW-T Installation and Programming Manual 7
3 Installation
3.1 SIM Card Insertion in the CelluLine CGW-T Unit
Caution
To avoid damage to the CelluLine CGW-T unit, the 9V adapter should be disconnected from
the electric power-outlet.
The physical description of the unit can be used as guideline for the following steps:
• Hold the unit in your hands with the display pointed to your left and the SIM insertion
slot at the bottom of the unit towards you. (The text SIM will be upside-down!)
• Use a pointed screwdriver to push the yellow SIM release lever, so that the SIM card
tray moves towards you.
• Take out the tray. You will see that the SIM card will fit in the tray in one way.
• Now carefully place the tray with the SIM card in the slot and slide it in with the SIM
card contacts facing down.

8 CelluLine CGW-T Installation and Programming Manual
3.2 CelluLine CGW-T Installation
• Mount the CelluLine CGW-T unit on the wall as a stand-alone unit or on the 6-fold wall
mount bracket, which is a separate accessory.
• Connect the Antenna into the Ant. connector on the side panel of the CelluLine CGW-T
unit.1
• Connect the analog trunk interface of the PBX to the trunk connector on the side panel of
the CelluLine CGW-T unit.
• Connect the power supply to the CelluLine CGW-T unit.
• The unit will start the initialization and registration. At the end of the process, the LCD
will display the GSM signal status.
Note:
1Experiment with the location of the antenna. The LCD gives an indication where you get the
best GSM reception.
The following figure gives a schematic representation of the CelluLine CGW-T unit setup.

CelluLine CGW-T Installation and Programming Manual 9
4 LCD Status Indicators and Diagnostics
The CelluLine CGW-T GSM Gateway can be connected to the analog trunk interface of the
PBX. At power-up of the CelluLine CGW-T GSM Gateway unit, the information on the LCD
will provide the first diagnostics. In many cases further diagnostics is not needed. By
connecting an analog telephone with the RJ-11 connector to the trunk connector in the unit,
you are able to perform further diagnostics.
4.1 LCD Status Indicators
The following table shows the messages appearing on the LCD, their description and the
action to be taken (if any).
LCD Message Description Action
Searching
Network… Searching for the mobile
network. No action needed.
Enter PIN code CGW-T needs the PIN code
to activate the SIM card.
1. Connect an analog telephone
to the unit and enter the code.
(4-8 digits. Add a # to the code
when using less than 8 digits)
2. Alternatively, insert the SIM
into your mobile phone and
disable the security option.

10 CelluLine CGW-T Installation and Programming Manual
LCD Message Description Action
Enter PUK code CGW-T received 3 times an
incorrect PIN code.
Request the PUK code from
your local GSM operator and
enter it into the CGW-T.
Registration… Registration process after the
mobile network has been
found.
Wait till registration phase is
finished.
S=X % LCD shows signal level in
intervals of 20% (20%, 40%,
60%, 80%, 100%).
If 20% or No signal, move the
antenna to another location
with a better reception.
Name operator Name of Operator (read from
mobile network). No action is needed.
Calling… CGW-T dials to destination. Wait.
Connected When called party answers. No action needed.
Disconnected End of call. No action needed.
Incoming Call CGW-T gets call from
network. No action needed.

CelluLine CGW-T Installation and Programming Manual 11
LCD Message Description Action
Failed CGW-T receives incorrect
operation information from
the mobile network. Try again.
Engine Problem GSM engine problem. Power off and on the unit. If
error is repeated, the unit is
faulty.
No Signal No Signal or Signal low (less
than 20%).
1. Check your antenna
connection.
2. Move your antenna to a
location with a better reception.
3. Check with your GSM
operator.
Reg. Denied Registration denied and/or
SIM card is not readable. Replace the SIM card.
Contact your GSM operator.
Insert SIM Card No SIM card inserted. Insert SIM card.

12 CelluLine CGW-T Installation and Programming Manual
4.2 Diagnostics
Connect an analog telephone to the trunk connector (RJ-11) on the unit.
Pick up the phone and if you receive:
• A continuous dial tone, the unit is working correctly.
• A busy tone, check for a message on the LCD.

CelluLine CGW-T Installation and Programming Manual 13
5 DTMF Programming
The CelluLine CGW-T GSM Gateway can be programmed via DTMF. The following steps
describe the procedure:
a. In case the CGW-T is connected to the PBX, remove the cable from the “Trunk”
connector on the unit.
b. Connect an analog telephone directly to the “Trunk” connector on the unit.
c. Dial *900.
d. After hearing the confirmation tone, enter the password (1234 by default).
Notes:
The CelluLine CGW-T will not answer any incoming calls when the analog telephone is
directly connected to the unit.
Exit from the programming mode by *900 or hanging up the telephone.
When you don’t enter digits for 45 seconds, the unit will automatically exit the programming
mode.
When entering an incorrect command, you will hear a beep.
When entering a correct command, you will hear two beeps.

14 CelluLine CGW-T Installation and Programming Manual
Operation Command Default
Enter the Programming
mode. *900 + XXXX
where:
XXXX = Password (1234
default)
1234
Exit the Programming
mode. *900
Maximum number of
digits to be dialed by the
CGW-T.
Notes:
Less than XX digits, then
there will be a time-out of
3 seconds (default),
before the dialing starts.
Exactly XX digits, then
the number will be dialed
directly.
More than XX digits,
then the number will be
cut off after XX has been
reached.
*300 + XX
where:
XX = 05-20 (digits)
11 (Tip: set the default
to country’s max.
telephone number
length.)
Table of contents
Other ITS Telecom Gateway manuals

ITS Telecom
ITS Telecom CGW-D User manual

ITS Telecom
ITS Telecom CGW-D Operating instructions

ITS Telecom
ITS Telecom CGW-I Operating instructions

ITS Telecom
ITS Telecom CelluLine CGW-TS Assembly instructions

ITS Telecom
ITS Telecom CGW-T Assembly instructions

ITS Telecom
ITS Telecom CGW-T4 Assembly instructions