5
TRANSPORTATION AND STORAGE
The pump may be transported and stored in a vertical
or horizontal position. Make sure that it is securely
fastened and cannot roll or fall over.
Always lift the pump by its carrying handle or lifting
eyes, never by the motor cable or the hose.
The pump is frostproof as long as it is operating or is
immersed in the liquid. If the pump is taken up when
the temperature is below freezing, the impeller may
freeze. The pump shall be operated for a short period
after being taken up in order to expel all remaining
water.
A frozen impeller can be thawed by allowing the pump
to stand immersed in the liquid for a short period
before it is started. Never use an open flame to thaw
the pump.
For longer periods of storage, the pump must be
protected against moisture and heat. The impeller
should be rotated by hand occasionally (for example
every other month) to prevent the seals from sticking
together. If the pump is stored for more than 6 months,
this rotation is mandatory.
After a long period of storage, the pump should be
inspected before it is put into operation. Pay special
attention to the seals and the cable entry.
Follow the instructions under the heading “Before
starting”.
CP 3060
With discharge connection assembly
Control equipment for start, stop and alarm.
Cable holder for holding the cable and regulating the
height of the level sensors.
Access frame (with covers) to which the upper guide
bar bracket and cable holder can be attached.
Discharge connection for connecting the pump to
the discharge line. The discharge connection has a
flange which fits the flange on the station piping. The
pump casing mates with the discharge connection,
which also has bosses for holding the guide bars.
Safety precautions
In order to minimize the risk of accidents in connection
with the service and installation work, the following
rules should be followed:
1.Make sure the lifting equipment is in good condi-
tion.
2.Be aware of the risk of electrical accidents.
3.Use a safety helmet, safety goggles and protective
shoes.
4.Do not ignore the risk of drowning.
5.A first-aid kit must be handy.
Follow all other health and safety rules and local
codes and ordinances.
At certain installations and
operation points on the pump
curve the noise level 70 dB, or
for the actual pump specified
noise level, can be exceeded.
INSTALLATION
Installation alternatives
C3060
CP version
In the CP version, the pump is installed on a station-
ary discharge connection and operates completely or
partially submerged in the pumped liquid.
In addition to the pump, the following items are
required:
Guide bars consisting of two stainless steel pipes.
Upper guide bar bracket for attaching the guide bars
to the access cover or top of the station.