Jade JB Manual

P/N 24-139 REV A 7/00 Page 1
RANGE BROILER and CHICKEN BROILER
MODELS: JB, JCB, JCBH
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
NOTE: Instructions must be posted in a prominent location, which will instruct the user in the event that
he/she detects the smell of gas. This information shall be obtained from your local gas company.
FOR YOUR SAFETY
Do not store or use gasoline
or other flammable vapors or
liquids in the vicinity of this or
any other applianc
e.
WHAT TO DO IF YOU SMELL GAS
•Open windows
•Do not touch electric switches
•Extinguish any open flame
•Immediately call your gas company
WARNING
Improper installation, adjustment, alteration, service or
maintenance can cause property damage, injury or death.
Read the installation, operating and maintenance instructions
thoroughly before installing or serving this equipment.
Jade Range, LLC.
2650 Orbiter Street
Brea, CA 92821
Telephone 714-961-2400
Fax 714-961-2550

P/N 24-139 REV A 7/00 Page 2
Adequate clearances must be provided in front, rear and at sides of appliance for servicing. The
appliance area must be kept free and clear from combustibles. There must be no material or obstacles
obstruction the flow of combustion and ventilation air.
RETAIN THIS MANUAL FOR FUTURE REFERENCE

P/N 24-139 REV A 7/00 Page 3
IMPORTANT
Read these instructions before starting the installation. Upon receipt of you equipment,
thoroughly inspect it for any damage. If damage is observed, contact your delivering
agency immediately. After checking for damage, examine the markings on the
equipment to ensure that the type of gas is correct.
INSTALLATION
A qualified installer, service agency or gas supplier must perform installation and service.
Provisions shall be incorporated in the design of the kitchen to ensure an adequate supply
of fresh air for proper combustion.
It is suggested that for servicing and proper operation, at least 36 inches of free area be
provided to the front of the appliance.
The installation must conform with local codes, or in the absence of local codes, in the USA,
National Fuel Gas Code, ANSIZ223.1- latest edition.
Level appliance. Adjustable legs are provided. If the appliance is equipped with casters,
the installation shall be make with a connector that complies with the Standard for
Connectors for Movable Gas Appliances ANSIZ.69-latest edition and a quick disconnect
device that complies with the standard for Quick-Disconnect for Use With Gas Fuel,
ANSIZ21.41- latest edition.
Adequate means must be provided to limit the movement of the appliance without
depending on the connector and the quick-disconnect device or its associated piping to limit
he appliance movement the restraining means may be attached to the rear of appliance by
cable and hook.
The input rating of your equipment is for elevations up to 2,000 feet. For elevations above
2,000 feet, the rating must be reduced 4% for each 1,000 feet above sea level.
The appliance shall be installed with the following minimum clearances to adjacent
construction.
Combustible Non-combustible
Sides 9 inches 0 inches
Rear 14 inches 0 inches
The appliance shall be installed on non-combustible counters. When equipped with high
legs, with or without casters, the appliance may be installed on combustible floors.
GAS PIPING
This appliance is provided with a regulator, set at 5” W.C. for natural gas or 10” W.C. for
propane gas.

P/N 24-139 REV A 7/00 Page 4
A conveniently located gas shutoff valve, external to the appliance is required for complete
shutdown.
Be sure all valves are in a closed position before connecting to gas supply.
Connect appliance to gas supply line. Under no circumstances should the gas supply line
be smaller than the inlet pipe on the appliance. Use pipe compound on all pipe joints.
Compound must be resistant to the action of liquefied petroleum gases.
Check all gas connections for leaks using a soap and water solution. DO NOT USE AN
OPEN FLAME FOR CHECKING PURPOSES.
NOTE: Your appliance was tested, rated and adjusted at the factory before shipment and
should be ready for use at the site without any major adjustments.
LIGHTING AND RE-LIGHTING INSTRUCTIONS
Your appliance is equipped with constant burning pilots. Turn valves off. Wait 5 minutes.
Light pilots. Adjust pilots’ flames by using a screwdriver to turn pilot valve screw clockwise
or counter-clockwise. Turn burner valves on. If pilots go out, turn off valves and repeat
above procedure.
MAINTENANCE INSTRUCTIONS
Contact the factory, factory representative or a local service company to perform
maintenance and repairs.
For daily cleaning, turn “ON” burner valves for 2 to 3 minutes and then turn “OFF.” Use
warm water and mild cleanser on top grates.
Once a month, clean all burners with water and steel brush ensuring that all burner ports are
free of debris. Clean pilots in same manner. Once cleaned and dried, re-light pilots and
check for blockage. As frequently as necessary, remove grease tray, empty and clean with
mild detergent.
WARNING: A GAS REGULATOR MUST BE INSTALLED FOR
THE SAFETY AND PROPER OPERATION OF THIS APPLIANCE
This appliance and its individual shut off valve must be disconnected from the gas
supply piping system during any pressure testing of that system at test pressures
in excess of ½ psig (3.45 kPa). The appliance must be isolated from the gas
supply piping system by closing its individual manual shut off valve during any
pressure testing of the gas supply piping system at test pressure equal to or less
than ½ psig (3.5 kPa).

P/N 24-139 REV A 7/00 Page 5
SERVICE INTERVALS
The need for servicing will, to a great extent, be determined by the appliance usage. The
following chart outlines our suggestion for service intervals:
Days Per Week Service Intervals
Normal Use
(5 hrs. /day)
Heavy Use
(12 hrs./day)
7 60 days 30 days
5 to 6 120 days 60 days
1 to 4 180 days 120 days
It is strongly suggested that a trained gas appliance service company examine the appliance at
least yearly.
REPAIR GUIDELINES
All repair work must be completed by a licensed-trained service person experienced in
commercial gas food service equipment.
If it becomes necessary to replace any gas control device, such as a main burner valve or
thermostat, the replacement part should be ordered from the factory only, unless it has been
determined that the EXACT part is available from your local parts supplier.
IMPORTANT: When the appliance is equipped with casters, the installation shall be made with
a connector that complies with the standard for Connectors for Movable Gas Appliances,
ANSIZ21.69-1987, and Addenda, Z21.691989, and a quick-disconnect device that complies
with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSIZ21.41-1989.
Adequate means must be provided to limit the movement of the appliance without depending on
the connector and the quick-disconnect device or its associated piping to limit the appliance
movement.
The connector or restraining device must always be installed when the appliance is in use.
Should it become necessary to remove this device for cleaning or servicing the appliance, be
sure to reconnect this restraining device after the appliance is returned to its originally installed
position.
WARNING: FOR YOUR SAFETY, DISCONNECT GAS AND POW
ER
SUPPLY TO THE APPLIANCE BEFORE SERVICE.

P/N 24-139 REV A 7/00 Page 6
INSERT -- Restraining device picture.
This manual suits for next models
2
Table of contents
Other Jade Broiler manuals

Jade
Jade TITAN J JSB-36 Operating and safety instructions

Jade
Jade TITAN JTRH-36B-36 Operating and safety instructions

Jade
Jade CHITWOOD SMOKE BROILER KC-24 Operating and safety instructions

Jade
Jade CHITWOOD SMOKE BROILER KC-24 Installation and operating instructions

Jade
Jade TITAN JTKC-24 Operating and safety instructions