Jaton Communicator V.90 User manual

Communicator V.90Communicator V.90
Internal 56Kbps Faxmodem
with VoiceMail and Caller ID
User Manual
version3.00
Copyright © 2000 Jaton Corporation, USA

ii
UNITED STATES - FEDERAL COMMUNICATIONS COMMISSION
CONSUMER INFORMATION AND REQUIREMENTS
Part 15-Radio Interference
This equipment has been test and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of FCC rules. These limits are design to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses, and can radiate
radio frequency energy if is not installed and used in accordance with the instructions. It is may
causes harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, please turning the it off is determination. The user
encouraged to try to correct the interference by one or more of the following measures:
1. Reorient the receiving antenna
2. Increase the separation between the equipment and the receiver
3. Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
4. Consult with the dealer or an experienced radio or television technician for help.
Notice 1:
The changes or modifications not expressly approved by the party responsible for compliance could
void the user's authority to operate the equipment
Notice 2:
Shielded interface cables and AC. power cord, if any, must be used in order to comply with
emission limits
Part 68 --Telephone Connection
This equipment complies with Part 68 of the FCC Rules. Inside this equipment was a label that
contains, among other things, the FCC Registration Number and Ringer Equipment Number (REN)
for this equipment. You must, upon request, provide this information to your telephone company.
The REN is useful to determine the quantity of devices you may connect to your telephone line and
still have all those devices ring when your telephone number might call. In most, but not all areas,
the sum of the REN's of all devices you may connect to one line should not exceed five (.5.0). To be
certain of the number of devices you may connect to your line, as determined by the REN. You
should contact your local telephone company to determine the maximum REN for your calling
area.
If your equipment cause harm to another telephone equipment, the Telephone Company may
discontinue your service temporarily. If possible, they will notify you in advance. Instead of
advance notification is not possible and you will be notify as soon as possible. You will be inform
of your right to file a complaint with the FCC.
Your telephone company may make changes in its facilities, equipment, operations or procedures
that would affect the proper functioning of your equipment. You will be notify in advance to give
you an opportunity to maintain uninterrupted telephone service.

iii
If you experience trouble with this telephone equipment, please contact Technical Support of your
OEM supplier. The telephone company may ask that you disconnect this equipment from the
network until the problem has been correct or until you are sure that the equipment is not
malfunctioning.
This equipment might not be use on coin service provided by the telephone company. Connection to
party lines is subject to state tariffs.
Statement of Fax Branding
The Telephone Consumer Protection Act of 1991 makes it unlawful statement which for all people.
Every one who uses a computer or other electronic device to send any message via a telephone fax
machine, must be clearly contains a margin at the top or bottom of each transmitted page. The first
page of the transmission, the date and time it sent and an identification of the huskiness or other
entity.
CANADA-DEPARTMENT OF COMMUNICATIONS NOTICE
Telephone Connection
The Canadian Department of Communications label identifies certified equipment. This
certification means that the equipment meets certain telecommunications network protective,
operational and safety requirements. The department does not guarantee the equipment will operate
to the user's satisfaction.
Before installing this equipment, users should assure that it is permissible to be connect to the
facilities of the local telecommunications company. The equipment must also be install using an
acceptable method of connection. In some cases, the company's inside wiring associated with a
single line individual service may be extend by means of a certified connector assembly (telephone
extension cord). The customer should be aware that compliance with the above conditions may not
prevent degradation of service in some situations.
Repairs to certified equipment should be handle with by an authorized Canadian maintenance
facility designated by the supplier. Any repairs or alterations made by the user to this equipment or
equipment malfunctions, may give the telecommunications company cause to request the user to
disconnect the equipment.
The user should assure for their own protection. That the electrical ground connections of the power
utility, telephone lines and internal metallic water pipe systems, if present, are connected together
This precaution may be particularly important in rural areas.
CAUTION:
Users should not attempt to make such connections themselves, but should contact the appropriate
electric inspection authority, or electrician, as appropriate.
The Load Number 2 assigned to each terminal device connotes the percentage of the total load to be
connect to a telephone loop that is use by the device, to prevent overloading. The termination on a

iv
loop may consist of any combination of devices subject only to the requirement that the total of the
Load Numbers of all the devices does not exceed 100.

v
NOTICE:
The information in this document is subject to change in order to improve reliability, design, or
function without subsequent notice and does not represent a commitment on the part of this
company. The information in this manual is believe to be accurate. However, we assume no
responsibilities for any inaccuracies that may be contain in this manual. In no event will we be
liable for direct, indirect, special, incidental, or consequential damages arising out of the use. The
inability is use to the product or documentation, even if advised of the possibility of such damages.
No part of this reference manual may be reproduced or transmitted in any form or by any means
without the subsequent written permission.
This product is not designed for use in life critical situations. This product component or support
assistance by manufacturer is within a period time only.
Life support devices or systems are define as devices that are Intended for surgical implant into the
body. For support or sustaining life and whose failure to perform with the instructions provided by
the manufacturer, might result in injury to the user.
June, 1999 Rev.A
TRADEMARK ACKNOWLEDGMENTS
Microsoft and Microsoft Windows are register trademarks of Microsoft Corp.
All other product names or trademarks are property of their respective owners.
Copyright protection claimed includes all forms and matters of copyrightable material and infor-
mation. Now allowed by statutory or judicious law or hereinafter granted, including without limita-
tion, material generated from the software programs that are display on the screen such as icons,
screen display looks, etc. Reproduction or disassembly of embedded computer programs or
algorithms prohibited.

vi
Table of Contents
CHAPTER 1 INTRODUCTION................................................................8
FEATURES ..................................................................................................8
SPECIFICATIONS..........................................................................................9
SYSTEM REQUIREMENTS............................................................................10
MODES OF OPERATIONS ............................................................................10
CHECK LIST:.............................................................................................13
CUSTOMER SUPPORT.................................................................................13
CHAPTER 2 HARDWARE......................................................................14
BOARD LAYOUT .......................................................................................14
MODEM INTERFACES.................................................................................15
HARDWARE INSTALLATION STEPS:............................................................16
CHAPTER 3 SOFTWARE .......................................................................18
SOFTWARE INSTALLATION........................................................................33
CHAPTER 4 TROUBLE SHOOTING....................................................35
MODEM BASIC..........................................................................................35
TECHNICAL TIPS .......................................................................................39
PROBLEMS AND SOLUTIONS:......................................................................40
CHAPTER 5 AT COMMANDS...............................................................44
OVERVIEW ...............................................................................................44
AT COMMANDS........................................................................................45
V.42/V.42BIS MNP AT COMMANDS.........................................................55
DATA ERROR CORRECTION AND COMPRESSION..........................................55
FAX CLASS 1 AT COMMANDS ...................................................................57
IS-101 VOICE AT COMMANDS..................................................................59
V.80 VIDEOCONFERENCING MODE COMMANDS.........................................61
S-REGISTER SUMMARY .............................................................................62
LIMITED WARRANTY. ............................................................................65
OTHER LIMITS..........................................................................................65
EXCLUSIVE OBLIGATION...........................................................................65
OTHER STATEMENTS. ...............................................................................66

vii
TERMS AND CONDITIONS..........................................................................66
SERVICES AGREEMENT:.............................................................................66
ENTIRE OBLIGATION. ...............................................................................67
REDUCING WARRANTY CLAIM REJECTIONS. ...................................67

8
CHAPTER 1 INTRODUCTION
Congratulations on you purchase The Communicator V.90 to manage your
desktop multimedia demands and communication needs. The
Communicator V.90 transforms your computer into a fax machine, a data
terminal, an Internet connection, a voice mail system, and a speakerphone.
The 56kbps Fax/Data/Voice modem supports industry-standard feature for
data, fax, and voice applications, plus advanced features such as 56kbps
Internet download with V.90 ITU-T,full duplex speakerphone, and caller
ID.
This hardware reference manual contains all the information you need to
install and configure with your Communicator V.90 card. You should still
retain this manual for future reference.
Features
• V.90 ITU-T standard modulation
• V.34, V.32 bis, V.32, V.22 bis, V.22A/B, V.23, V.21, Bell 212A,
Bell 103 Data Modem
• V.42 LAPM, MNP 2-4, and MNP 10 error correction
• V.42 bis and MNP 5 data compression
• V.17 Fax Modem send and receive rates up to 14,400 bps
• V.80 Videoconference synchronous access modes support host
based communication protocols, e.g. H.324 Videoconferencing
• IS 101 Standard Voice Modem
• Voice compression: ADPCM, linear, and CL1
• Full Duplex Speakerphone (INTEL / AMBIENT MD5662 only)
• Caller ID and distinctive ring detect
• NVRAM directory and stored profiles
• Built-in DTE interface parallel 16550A UART compatible

9
• Integrated data communication, Fax, Voice software
• Plug and Play or Jumper Select Configuration
Specifications
Modem Communication:
Data Communication Standards
Modulation: V.90, V.34, V.32bis, V.32 V.23, V.22bis, V.22, V.21
and Bell 212A & 103
Data Rates: 57.3K, 56K, 54.7K, 53.3K, 52K, 50.7K, 49.3K, 48K,
33.6K, 31.2K, 28.8K, 26.4K, 24K, 21.6K, 19.2K,
16.8K, 14.4K, 12K, 9600, 7200, 4800, 2400, 1200
and 300 bps
Integrity: V.42 LAPM, MNP 2-4, and MNP 10 error correction
Compression: V.42 bis or MNP Class 5
Commands: AT & V.25bis AT Voice
Fax Standards
Modulation: ITU-T V.17, V.29, V.27 ter, and V.21 channel 2
Data Rate: 14,400, 12,000, 9600, 7200, 4800, 2400, 300 bps
Format: ITU-T T.4 Group 3 Fax
Handshake: ITU-T T.30 Group 3 Fax
Commands: EIA/TIA-578 data/fax Class 1
Voice Standards
Commands: EIA/TIA IS-101
Voice Sample Rate: 4800, 7200, 8000, 9600, 11025 samples per second
Voice Compression: ADPCM, linear, CL1
Physical/Electrical/Environmental
Dimensions: 3.5" x 6.2" ( 14 cm x 15.7 cm )
Cables: 6’ Phone cord with RJ11 jack

10
Connectors: 2 RJ11 jacks for telephone and PSTN line
connections
Speaker Interface: Minimum load 8 Ohm, Maximum load 100 Ohm
Humidity: 20-90% (non-condensing)
Temperature: 0° to 70° C (32° to 158° F)
Humidity: 20-90% (non-condensing)
Transmit Level: -10 dBm ±1 dB dial-up; Programmable.
Receive Level: -9 to -43 dBm. DCD is deactivated below -48dBm.
System requirements
• x86 Compatible PC with one free 16-bit ISA Expansion Slot
• Quad speed or faster CD-ROM drive
• Hard Disk Drive with 10MB or more available free space
• Microphone, speakers or headset (for audio application)
Modes of Operations
The Communicator V.90 provide the complete modem functions for the
following modes: Group 3 fax, data, voice, V.42/MNP 2-4, and V.42
bis/MNP 5 (Microcom Networking Protocol Class 5). Each mode has its
own unique AT command set. Additionally, the modem provides special
modes of operation for power management.
DATA MODE
In the data mode, the modem allows data to be received at speed up to 56
kbps. Taking advantage of the PSTN, which is primarily digital except for
the central office local loop, this modem is ideal for remote access
applications such as Internet Service Provider, On-line service, or corporate
site. As a client modem, data can be sent at speed up to 31.2 kbps.
As a V.34 data modem, the modem operates at line speeds up to 33.6 kbps.
Error correction and data compression maximize data transfer integrity and
boost average data throughput up to 115.2 kbps.
Table of contents