JDS Uniphase PathTrak HCU200 User manual

Artisan Technology Group is your source for quality
new and certied-used/pre-owned equipment
• FAST SHIPPING AND
DELIVERY
• TENS OF THOUSANDS OF
IN-STOCK ITEMS
• EQUIPMENT DEMOS
• HUNDREDS OF
MANUFACTURERS
SUPPORTED
• LEASING/MONTHLY
RENTALS
• ITAR CERTIFIED
SECURE ASSET SOLUTIONS
SERVICE CENTER REPAIRS
Experienced engineers and technicians on staff
at our full-service, in-house repair center
WE BUY USED EQUIPMENT
Sell your excess, underutilized, and idle used equipment
We also offer credit for buy-backs and trade-ins
www.artisantg.com/WeBuyEquipment
REMOTE INSPECTION
Remotely inspect equipment before purchasing with
our interactive website at www.instraview.com
LOOKING FOR MORE INFORMATION?
Visit us on the web at www.artisantg.com for more
information on price quotations, drivers, technical
specications, manuals, and documentation
Contact us: (888) 88-SOURCE | sales@artisantg.com | www.artisantg.com
SM
View
Instra

JDSU PathTrak™
HCU200 Install User’s Guide


PathTrak™ HCU200 Install User’s Guide Rev. 000 i
Notice
The information contained in this document is the sole
property of JDSU and may not be reproduced, copied,
or communicated to third parties without written notice
and permission by JDSU. This material will be given to
direct partners and developers working with JDSU who
have signed non-disclosure agreements. Such second
parties may freely copy and distribute this information
within their organizations but agree to keep such
communications restricted to their internal employees
on a need-to-know basis.
Copyright
Copyright © 2010 JDSU. All rights reserved.
System
Require-
ments
HCU200 Module
-48V DC Power Supply (+/- 5%, 1A max current)
10/100 BaseT Ethernet connection with static IP
RF Feed(s) (0-50 dBmV input level)
PathTrak Server/Client Software Version 2.6 or higher
Server PC (See "PathTrak and WebView System
Requirements" for details)
CAUTION
Be sure that power is off on the -48V DC power source
before connecting or disconnecting power leads to the
HCU200.
Do NOT install HCU200 modules unless properly trained in
handling ESD-sensitive materials like the HCU200. Any
damage caused by improper or incorrect handling voids the
entire PathTrak system warranty.

ii PathTrak™ HCU200 Install User’s Guide Rev. 000

PathTrak™ HCU200 Install User’s Guide Rev. 000 iii
Table of Contents
Section 1 Getting to know the HCU200 1
Section 2 HCU200 Unpacking and Setup 2
Section 3 Related Information 8
Section 4 Technical Assistance 9
Section 5 Warnings 11
Section 6 Equipment Ratings 12

iv PathTrak™ HCU200 Install User’s Guide Rev. 000

Section 1: Getting to know the HCU200
PathTrak™ HCU200 Install User’s Guide Rev. 000 1
Section 1: Getting to know the HCU200
The front panel consists of:
The power button
The 4 cursor or arrow keys
The "Enter" or "Accept" button
The "Exit or "Cancel" button
The information LCD

Section 2: HCU200 Unpacking and Setup
2PathTrak™ HCU200 Install User’s Guide Rev. 000
Section 2: HCU200 Unpacking and Setup
1Remove HCU200 from box and carefully remove all
packaging material.
2Mount HCU200 module in rack using the four holes
provided on the front panel.
3Connect grounding strap of chassis to Earth
Grounding termination screws on the rear panel of
the HCU200.
4Remove the protective cover over the DC power
lugs on the rear panel of the HCU200.
aIf using an existing -48VDC power supply
double-check that power is turned off. Connect
the -48V and RTN leads from the power supply
to the appropriate power lugs on the rear panel
of the HCU200.
bIf using the JDSU-supplied optional AC power
adaptor, connect the adaptor terminals to the
appropriate HCU200 power lugs. Black wire
goes to -48VDC lug, white wire goes to RTN
lug.
5Replace the clear plastic cover over the power lugs.
6Connect jumpers from the RF source (commonly 8-
way splitter off of return optical receiver) to the
appropriate ports on the rear of the HCU200.
7If using an HSM-1000 for Field View capability
please see Document 6710-30-0005 (HSM-1000
Install Guide) for details of HSM installation and
configuration.
8Connect Ethernet feed to RJ45 connector socket on
the rear of the HCU200.
9Apply power to the HCU200. Once power is
applied to the HCU200 the LCD will display:

Section 2: HCU200 Unpacking and Setup
PathTrak™ HCU200 Install User’s Guide Rev. 000 3
Figure 1 LCD Display Screen and Keypad
Figure 2 LCD Display at Start-Up
10 After approximately 20 seconds the LCD will
display:
Figure 3 IP Address of HCU200
Figure 4 explains what each line and/or symbol on the
LCD is showing.
Figure 4 Explanation of LCD Fields
NOTE
The actual IP address that appears may be different than
shown below.

Section 2: HCU200 Unpacking and Setup
4PathTrak™ HCU200 Install User’s Guide Rev. 000
There are five different fields that may be viewed on the
LCD by using either the up or down arrow keys to scroll.
Three may be edited, the other two which are for infor-
mational purposes only.
Shown below are the three fields which may be edited:
(All field values may be different from what is shown)
Figure 5 IP address of the HCU200
Figure 6 Subnet mask of the HCU200
Figure 7 Default gateway of the HCU200
Figure 8andFigure 9showtheremainingtwofieldsthat
are informational only and cannot be edited from the
HCU200 front panel. The horizontal line immediately
below the down arrow is not present in these two fields
indicating that they cannot be edited via the front panel.

Section 2: HCU200 Unpacking and Setup
PathTrak™ HCU200 Install User’s Guide Rev. 000 5
Figure 8 Physical (MAC) address of the HCU200
Ethernet adapter
Figure 9 IP address of the PathTrak server that this
HCU200 is connected to (This will change/
update when the HCU200 is added to a
new server)
11 Using the keypad and display on front panel or
PathTrak Client software, IP address of HCU200 to
appropriate value. Setting the IP address informa-
tion on the HCU200 is a simple process done
completely from the front panel of the unit.
12 To set the IP address of the HCU200, use the up or
down arrow keys to scroll to the IP address field on
the LCD and press the "Enter" button. The hori-
zontal line that indicates that this is a field that may
be edited drops to the bottom of the first digit in the
IP address field becoming a cursor and indicating
that the HCU is now in "edit mode" (Figure 10).
CAUTION
Before setting any IP address information in the HCU200,
please confirm with your network administrator that the IP
addresses you have are valid for your network configuration
and will not cause any conflicts on your local area network.

Section 2: HCU200 Unpacking and Setup
6PathTrak™ HCU200 Install User’s Guide Rev. 000
Figure 10 IP Address in Edit Mode
13 Use the up or down arrow keys to set the first
number of the first IP address octet (range blank
thru 2). If the first octet is less than 100, scroll until
the digit is blank. Once the first number is set, use
the right arrow key to move the cursor to the second
number of the first IP address octet (Figure 11).
Figure 11 IP Address in Edit Mode (1st Octet)
14 Use the up or down arrow keys to set this number to
the proper value (range 0 thru 9). Once this
number is set, use the right arrow to move the
cursor to the next digit.
15 Follow the same process until the correct IP
address shows on the display and then press
"Enter". This will save the address information and
place the unit back in normal operation mode.
16 Now, press the down arrow to go to the subnet
mask field and repeat the process used to set the IP
address. When the subnet mask is correct, press
the down arrow and repeat once more for the
default gateway.

Section 2: HCU200 Unpacking and Setup
PathTrak™ HCU200 Install User’s Guide Rev. 000 7
17 There is no need to reboot the HCU200. Once you
press the "Enter" button at the end of each field, the
address is set and applied. When all the addresses
are set, verify network connectivity from the Path-
Trak server to the HCU200.
18 The PathTrak Server AND Client must be at least
version 2.6 to recognize the HCU200.
19 Proceed with adding the HCU200 to a PathTrak
Server per instructions documented in Chapter
Three of document 6510-00-0430.
Figure 12 HCU200 Rear Panel

Section 3: Related Information
8PathTrak™ HCU200 Install User’s Guide Rev. 000
Section 3: Related Information
Use this guide in conjunction with the following informa-
tion:
– JDS Uniphase Corporation DSAM Product Family
Series Server/Client Complete DSAM Meter Func-
tionality Installation Guide (P/N 6510-30-0416)
– JDS Uniphase Corporation DSAM Product Family
Series RPM1000 Installation Guide
(P/N 6510-30-0415)
– JDS Uniphase Corporation DSAM Product Family
Series RPM2000 Installation Guide
(P/N 6510-30-0423)
– JDS Uniphase Corporation DSAM Product Family
Series RPM3000 Quick Start Guide
(P/N 21121380-001)

Section 4: Technical Assistance
PathTrak™ HCU200 Install User’s Guide Rev. 000 9
Section 4: Technical Assistance
If you need assistance or have questions related to the
use of this product, call or e-mail JDS Uniphase Corpo-
ration’s Technical Assistance Center for customer
support.
Table 1 Technical assistance centers
Region Phone Number
Cable
TV/Multimedia
Products
1 800 428 4424 Ext. 8350
(America)
1 317 788 9351 Ext. 8350
(World Wide)
Europe, Africa,
and Mid-East +49 (0) 7121 86 1345
(Europe) [email protected]
+800 882 85822
+49 (0) 6172 59 11 00
(JDS Uniphase
Corporation Germany)
+33 (0) 1 39 30 24 24
(JDS Uniphase
Corporation France)
Asia Pacific +852 2892 0990
(Hong Kong)
+86 10 6655 5988
(Beijing-China)

Section 4: Technical Assistance
10 PathTrak™ HCU200 Install User’s Guide Rev. 000
During off-hours, you can request assistance by doing
one of the following: leave a voice mail message at the
Technical Assistance number in your region; e-mail
North American Technical Assistance Center,
[email protected], or European Technical Assistance
using our online Technical Assistance Request form at
www.jdsu.com.

Section 5: Warnings
PathTrak™ HCU200 Install User’s Guide Rev. 000 11
Section 5: Warnings
The HCU200 is a Measurement Category I device for
measurements on circuits and SHOULD NOT be used
for measurements within measurement categories II, III
and IV circuits*.
* Measurement Category I: Such voltage measure-
ments include signal levels, special equipment,
limited-energy parts of equipment, circuits powered
by regulated low-voltage sources, and electronics.
WARNING
If the equipment is used in a manner not specified by the
manufacturer, the protection provided by the equipment may
be impaired.
WARNING
Do not disassemble the HCU.
Do not attempt to service this product yourself. There are no
user-serviceable parts inside. Contact the appropriate JDSU
representative for HCU repair or calibration.

Section 6: Equipment Ratings
12 PathTrak™ HCU200 Install User’s Guide Rev. 000
Section 6: Equipment Ratings
Input Connection Description
– 16 RF Input Ports, 75 ohm,
dynamic voltage range 0-50 dBmV
– 1 Serial RS232 port
– 1 10/100 baseT Ethernet port
– 1 USB port
– 1 Trigger I/O port
– 2 Earth Grounding Termination screws
Environmental Conditions
– Operating Temperature:
5°C (41°F) to 45°C (113°F)

Table of contents
Other JDS Uniphase Control Unit manuals
Popular Control Unit manuals by other brands

Edwards
Edwards LCPV16EKA instruction manual

Beckhoff
Beckhoff EtherCAT Box quick start guide

National Instruments
National Instruments FlexRIO PXIe-79 R Series installation guide

Waterworks
Waterworks GUTH56 Installation guidelines

CALEFFI
CALEFFI SATK40 Series INSTRUCTIONS FOR INSTALLATION, COMMISSIONING AND MAINTENANCE

Lutron Electronics
Lutron Electronics QSGRK-6D Quick installation and operation guide