
Section 2: HCU200 Unpacking and Setup
2PathTrak™ HCU200 Install User’s Guide Rev. 000
Section 2: HCU200 Unpacking and Setup
1Remove HCU200 from box and carefully remove all
packaging material.
2Mount HCU200 module in rack using the four holes
provided on the front panel.
3Connect grounding strap of chassis to Earth
Grounding termination screws on the rear panel of
the HCU200.
4Remove the protective cover over the DC power
lugs on the rear panel of the HCU200.
aIf using an existing -48VDC power supply
double-check that power is turned off. Connect
the -48V and RTN leads from the power supply
to the appropriate power lugs on the rear panel
of the HCU200.
bIf using the JDSU-supplied optional AC power
adaptor, connect the adaptor terminals to the
appropriate HCU200 power lugs. Black wire
goes to -48VDC lug, white wire goes to RTN
lug.
5Replace the clear plastic cover over the power lugs.
6Connect jumpers from the RF source (commonly 8-
way splitter off of return optical receiver) to the
appropriate ports on the rear of the HCU200.
7If using an HSM-1000 for Field View capability
please see Document 6710-30-0005 (HSM-1000
Install Guide) for details of HSM installation and
configuration.
8Connect Ethernet feed to RJ45 connector socket on
the rear of the HCU200.
9Apply power to the HCU200. Once power is
applied to the HCU200 the LCD will display: