4
Cabinet Dimensions
*NOTE: Grills installed near a side wall must allow a minimum 
clearance of 6" (15.2 cm) between cooktop and sidewall for 
maximum performance. Minimum clearance of 1" (2.5 cm) is 
required to sidewalls and ¾" (1.9 cm) to rear wall.
NOTES: After making the countertop cutout, some installations 
may require notching down the base cabinet side walls to clear 
the cooktop base. To avoid this modification, use a base cabinet 
with sidewalls wider than the cutout.
■Where possible, a 6" (15.2 cm) clearance is recommended for 
motor blower service. A minimum clearance of 1" (2.5 cm) is 
recommended to the sidewalls and a ³⁄₄" (1.9 cm) clearance is 
recommended to the rear wall.
■A minimum clearance of 2" (5.1 cm) is recommended 
between the motor/blower and cabinet for proper cooling.
■A minimum clearance of 6¹⁄₄" (15.9 cm) is recommended for 
removal of the grease container(s). Installed dimension for the 
grease containers is 5¹⁄₂" (14.0 cm). 
■For grills installed near a sidewall, a minimum clearance of 
6" (15.2 cm) is recommended between the cooktop and 
sidewall for maximum performance.
Cutout Dimensions
Venting Requirements
■Do not terminate the vent system in an attic or other enclosed 
area.
■Use a Jenn-Air®vent cap.
■Vent system must terminate to the outside.
■Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is 
recommended. For best performance, do not use plastic or 
metal foil vent.
■Before making cutouts, make sure there is proper clearance 
within the wall or floor for the exhaust vent.
■Do not cut a joist or stud unless absolutely necessary. If a 
joist or stud must be cut, then a supporting frame must be 
constructed.
■The size of the vent should be uniform.
■The vent system must have a damper. If roof or wall cap has a 
damper, do not use damper supplied with the range hood.
A. 24" (61.0 cm) on 20" (50.8 cm) single cartridge models
30" (76.2 cm) on 30" (76.2 cm) double cartridge models
43" (109.2 cm) on 43" (109.2 cm) triple cartridge models
B. Combustible area above countertop (shown by dashed box above)
C. 30" (76.2 cm) minimum clearance between top of cooktop platform 
and bottom of uncovered wood or metal cabinet (24" [61 cm] 
minimum clearance if bottom of wood or metal cabinet is covered 
by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with 
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless 
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)
D. 13" (33 cm) recommended upper cabinet depth
E. 2¹⁄₈" (5.4 cm) min.
F. 20⁹⁄₁₆" (58.2 cm)
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop 
within minimum horizontal clearances to cooktop
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of 
countertop
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of 
cabinet
J. 18¹¹⁄₁₆" (47.5 cm) on 20" (50.8 cm) single cartridge models
30⁷⁄₁₆" (77.3 cm) on 30" (76.2 cm) double cartridge models
41³¹⁄₃₂" (106.6 cm) on 43" (109.2 cm) triple cartridge models
K. Side clearance - See *NOTE.
L. 2" (5.1 cm) minimum clearance between back wall and countertop 
cutout
D
A
E
I
J
K
G
H
L
C
F
B
A. 18¹¹⁄₁₆" ±¹⁄₁₆" (47.5 cm ±0.2 cm) on 20" (50.8 cm) single cartridge 
models
30⁷⁄₁₆" ±¹⁄₁₆" (77.3 cm ±0.2 cm) on 30" (76.2 cm) double cartridge 
models
41³¹⁄₃₂" ±¹⁄₁₆" (106.6 cm ±0.2 cm) on 43" (109.2 cm) triple 
cartridge models
B. 20⁹⁄₁₆" ±¹⁄₁₆" (52.2 cm ±0.2 cm) maximum on all models
C. 6⁵⁄₁₆" (16.0 cm) on 20" (50.8 cm) single cartridge models
17¾" (45.1 cm) on 30" (76.2 cm) double cartridge models
17¾" (45.1 cm) on 43" (109.2 cm) triple cartridge models
D. 14⁷⁄₁₆" (36.7 cm) on all models
E. 2¹⁄₈" (5.4 cm) minimum space to front edge of cooktop
F. Minimum cabinet width:
21" (53.3 cm) on 20" (50.8 cm) single cartridge models
33" (83.8 cm) on 30" (76.2 cm) double cartridge models
43" (109.2 cm) on 43" (109.2 cm) triple cartridge models
G. Floor exhaust option
H. 6¹⁄₈" (15.6 cm) for 6" vent system
I. 6⁵⁄₁₆" (16.0 cm) on 20" (50.8 cm) single cartridge models
17¾" (45.1 cm) on 30" (76.2 cm) double cartridge models
17¾" (45.1 cm) on 43" (109.2 cm) triple cartridge models
J. 8" (20.3 cm) from center of the vent hole in the cabinet to the top 
surface of the countertop, on all models
K. Wall exhaust option
AB
CD
E
G
H
I
J
K
F