INSTALLATIONOF APPLIANCE
Theinstallationof thisappliancemustconformwithlocalcodesor,inthe
absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1-LatestEdition,or,inCanada,CAN!CGA-B149InstallationCode,
LatestEdition.
This appliance, when installed, must be electrically grounded in
accordancewith localcodesor,inthe absenceof localcodes,with the
NationalElectricalCodeANSI!NFPANo.70-LatestEdition,or,inCanada,
currentCSAStandardC22.1CanadianElectricalCode,Part1.
In The CommonwealthOf Massachusetts
Thisproductmustbe installedbya licensedplumberor gasfitterwhe_
installedwithintheCommonwealthofMassachusetts.
A"F" handletypemanualgasvalvemustbeinstalledin thegassupply
linetothisappliance.
A flexiblegasconnector,whenused,mustnotexceeda lengthof
three(3)feet136 inches.
All supply piping,exceptas noted, shoulduse commonNational Pipe
Thread (N.RT.).For all pipe connectionsuse an approvedpipe joint
compoundresistantto theactionof LPgas.
CAUTION:WarrantyisvoidonJenn-Airequipmentinstalledotherthanas
recommendedbymanufacturer.
This applianceis designedfor use with the appliancegas pressure
regulatorsuppliedwiththis appliance.It mustbeinstalledinthe gasway
aheadofthegasmanifoldentrance.Itispresetforusewithnaturalgasand
mustbe converted,as describedon page8, for usewith LP gas. (See
figures10and11.)
This applianceis designedto operateat apressureof 5 inchesofwater
columnon naturalgasor, if convertedfor usewith LPgas (propaneor
butane),10incheswatercolumn.Makesurethisapplianceissuppliedwith
andadjustedforthetype ofgasforwhich itisdesigned.
Thisappliancewasadjustedatthefactoryforusewithnaturalgas.If,atany
time,this applianceis to be usedwith a differenttype of gas, all ofthe
conversionadjustmentsdescribedon pages7 and8 mustbe madebya
qualifiedservicetechnicianbeforeattemptingto operatethe cooktopon
thatgas.Naturalgasshouldbesuppliedtotheappliancepressureregulator
atalinepressurebetween6 and14inchesofwatercolumnor,ifconverted
for LPgas,between11and 14inches.
WARNING: If the line pressuresupplyingthe appliancepressure
regulatorexceeds14" W.C. (anygas),an externalregulatormustbe
installedinthegaslineaheadoftheapplianceregulatorto reducetheI
pressureto no morethan 14" W.C. Failureto do this can result in
mafuncton anddamagetotheapp ance.
Insurethisapplianceisadjustedforthetypeof gassuppliedto itandthat
the gas supplypressureto the applianceregulatoris within the proper
pressurerange.
• If this is a 45" wide model,or if it is a 30" widemodeland no other
applianceis to be installed in the cabinetrybelow it, proceedas
instructedunderparagraphf.
• If thisisa 30" widemodelanda Jenn-AirModelJJW8530,JJW9530,
W27100X,W30400PorW132XElectricWallOvenistobe installedin
cabinetrybelow,proceedasinstructedunderparagraphIf.
• Donotremoveprotectivecapfrompipestubatmanifoldentranceuntil
readyto joingassupplypipingto appliance.
NOTE:InCanada,gasutilizationcodesprohibituseofstreetelbows.Use
standardpipe elbows and make modificationsto these instructionsas
necessary.
CONNECTINGAPPLIANCETO GAS SUPPLY
AQUALIFIEDSERVICEMANORGASAPPLIANCEINSTALLERMUST
MAKETHEGASSUPPLYCONNECTION.Leaktestingoftheappliance
shall be conductedby the installeraccordingto the instructions
given.
1. IF NOOTHERAPPLIANCEIS TO BE INSTALLEDBELOWTHIS
COOKTOP
Join theappliancepressureregulatorsuppliedwiththis applianceto the
entrancethreadsoftheGasManifold.Theapplianceregulatorismarked
with a directionalarrowindicatingcorrectdirectionof gasflow.Ensurethe
applianceregulatoris installedwith the arrowpointingtoward the gas
manifoldentrance.Tightenthe applianceregulatorto 20 to 30 ft-tbs of
torque.
IIMPORTANT approved
Nevertightento morethan35ft-lbsoftorque.Alwaysusean
pipejointcompoundresistantto theactionof LPgas.
Installtheappliancein itscountercutout.
Makethe gasconnectionto the inletof the appliancepressureregulator
with 1/2"malepipethreads.
Installa manualshut-offvalve in an accessiblelocationin the gasline
aheadoftheappliancepressureregulatorandexternaltothisappliancefor
the purposeofturningonor shuttingoff gastotheappliance.
Makeadditionalpipeconnectionsasnecessaryaheadoftheshut-offvalve
to thegassupplysource.Assureall pipejointconnectionsaregastight.
IMPORTANT
Applya non-corrosiveleakdetectionfluidtoalljointsandfittingsinthe
gasconnectionbetweenthe supplyline shut-offvalveand the range.
Includegasfittingsandjointsin therangeifconnectionsweredisturbed
duringinstallation.Checkforleaks!Bubblesappearingaroundfittings
andconnectionswillindicatealeak.Ifaleakappears,turnoffsupplyline
gasshut-offvalve,tightenconnections,turnonthesupplylinegasshut
offvalve,and retestfor leaks.Nevertestfor gas leakswith an open
flame.
ILLUSTRATIVEGAS SUPPLYPIPING
i (NO OTHER APPLIANCE BELOW COOKTOP)
BURNER BOX
(REAROFAPPLIANCE)
UMANIFOLDENTRANCE
APPLIANCEPRESSURE
iREGULATOR
I
I
ALL PIPEJOINTS
1/2 N.P.T.
I
ELBOW
MANUAL
SHUTOFF
VALVE
TOGAS
FIGURE3 INLET