INSTALLATION
INSTRUCTIONS
PARTNo. 204347 BUILT-INELECTRICWALLOVENS _[] eLIoENMN-AlpA NRy
FOR 27"WALL CABINET 303sSHADELAN£)"INDIANAPOLISIN46226-0901
IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE.
CAUTION: If cabinet doors areprovided abovewall oven,
aminimum spacing of33/4'' is requiredfor 1/2"thick doors.
For thicker doors, increase the spacing 1" for each 1/4"
Jadditional thickness.
,._._CAUTION: Oven venIs.
27" _--_r-_.P4".r_inCAUTION: Oven vent,/1de no{ obstruct
do no_obstruct _'_ _J
Alternate _ _ -"--,.f.,_- _-_
location.
See Note 2. ] ]I _J"_
A
28-118" J
Conduitaccess hole/
ount,lv'a,
areaunder plywood floor
if adequate lower cabinet .23.,_-,,_-_ !OT_:_o_ /7,/
space isavailable. C_to_C_
Construct 5/8" min. SINGLE andbotlemofunit
plywoodfloor flush WALL OVEN %
with bottom of opening.23-114_.I
Floor must be capable '4
_f supporting 240 Ibs. DOUBLE
Jr Europeanstyle __ _ WALL OVEN
cabinets (flush front) the
required clearance for c
tion of the oven door isa min.
spacing of T/8"between the cutout
and the door, hinge or drawer of the cabinet.
Model A B C 4e_'4'
S ng eWa Oven 28%" 16%" 4" to 33" _
Combination 29"
WallOven477/a" 123/4"to 17W
Double Wall Oven J 50W' 38W' 3" to 12" _
Note1. Cutout Dimension A 4- _/_6"'Typicalcornerscrewinstallation
for all models #8 x 1"screw
Note 2. Locate junction box in shadedarea 23/,"
of rear wall so conduit will form a loopwhen :OMBINATION OVEN NOTE:Donorblockairintakeslots
LESSMICROWAVE along sidesand bottomof unit
ovenisinstalled. TRIM
1.Cut hole in cabinet to mount oven. Cutout in cabinet should be level and straight. NOTE: There are no provisions
to level the unit after it is installed. An oven that is not levelcould cause poor baking results.
2. Install plywood floor as shown above.
3.Attach unit to the cabinet with four No.8 x 1" screws supplied with unit inside of envelope containing these instructions.
Pre-drill holes in cabinet for attachment screws using 1/8" drill. Oven mounting holes are in each corner of front
panel.For combination units, install trim around microwave with four No.6 x W' screws supplied with unit. Pre-
drill holes in cabinet for attachment screws using 3/32"drill.
4. See instructions on opposite side of page for electrical hook-up.
5.See User's Manual for operating instructions.
6. CAUTION: Some 27" built-in cabinets may not be wide enough, due to their construction,to allow this installation.
7. Single Wall Oven is also U.L. listed to be installed as a combination unit using microwave models M130 or M166
with Jenn-Air trim kits A526 or A530. Install per instructions packed with trim kits.