3.Adjustairshuttersonindividualburnersforproper
flameappearance.
4.Adjustlowflamesettingateachburnerbyturning
adjustmentscrewincenterofvalvestem.
To make these conversion adjustments follow the
instructions and illustrations ("A" through "D").
IMPORTANT
Apply a non-corrosive leak detection fluid to all joints
and fitt ngs in the gas connecticn between the supply
ine shut-off valve and the range. Include gas fittings
and joints in the range if connections were disturbed
during installation. Check for leaks! bubbles appearing
around fittings and connections will indicate a leak. If
a leak appears, turn off supply line gas shut-off valve.
tighten connections, turn on the supply line gas shut
off valve, and retest for leaks. Never test for gas leaks
with an open flame.
This appliance is shipped from the factory with orifice
hoods drilled for use with natural gas. To convert from
natural gas to LP, apply a 1/2" open-ended wrench to hex
section of orifice hood. TURN COUNTERCLOCKWISE
TO REMOVE. Save the Natural Gas orifice hoods just
removed from this appliance for future use. Install color
coded orifice hoods supplied. (SEE GAS CONVERSION
INSTRUCTIONS PAGE 14.) TURN CLOCKWISE TO
INSTALL. Hold dimension specified in illustration "B".
CONTROL SETTINGS
The size and type of cookware and the amount and type
of food being cooked will influence the setting needed for
best cooking results. The setting indicated should serve
as a guide while you become familiar with your cooktop.
Use the Hi flame setting to -- -
quickly bring foods to a boil or to __ !_0_)
begin a cooking operation. Then
reduce to a lower setting to I
continue cooking. Never leave
food unattended over a Hi flame
setting.
Med setting is used to continue a
cooking operation. Food will not
cook any faster when a Hi flame
setting is used than that needed
to maintain a gentle boil.
Remember, water boils at the
same temperature whether
boiling gently or vigorously.
_ed
Use Lo setting to keep food at
serving temperatures without
further cooking. You may find
that some cooking may take
place if the cookware is covered.
AIR SHUTTER ADJUSTMENT
(See illustration "C")
This appliance is shipped from the factory with air
shutters adjusted for use with natural gas. If further
adjustment is necessary, or to reset for use with LP,
adjust air shutters as follows:
Grill Burner and Surface Burner Cartridge Air Shutters
(see illustration "C").
•The left hand air shutter controls the rear half of the
burner.
•The right hand shutter controls the front half.
• Access to air shutters on the surface burner cartridge
may be found through openings on the bottom of the
cartridge housing.
Slide air shutter backward or forward to increase or
decrease the size of the air opening. Air shutters fit
snugly, so a screwdriver blade may be required to make
this adjustment (see illustration.)
Observe change in flame appearance as the air shutter is
moved. Adjustment is satisfactory when a clearly defined,
even blue flame results at the high flame setting. The
snug fit of the air shutter assures it will remain positioned
correctly.
Onany burner, closing the air shutter too far wil!
cause the flame to become soft and yellow tipped,
Opening the air shutter too wide will cause the
flame to blow away from the burner ports. Proper
adjustment will produce a sharp, clearly defined;
even blue flame.
GRILL BURNER AIR SHUTTER & SURFACE BURNER
(IF SO EQUIPPED)
A,ROPEN,N
AIR SHUTTER'- /INSERT SCREWDRIVER BLADE
IN SLOT AND TWIST WITH
SLIGHT PRESSURE TO ALLOW
AIR SHUTTER TO SLIDE EASILY.
/
/
/
/
\
AIR SHUTTER
ILLUSTRATION "C"
-12-