Jesco INFINA DL-AC-FLEX User manual

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 1 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
Please read and save these instructions. Read carefully before using product. Protect yourself and others by observing all
safety information, warnings and cautions. Failure to comply with instructions could result in personal injury and/or damage
to product or property. Please retain instruction sheet for future reference.
DO NOT CUT OR SHORTEN INFINA. DOING SO CAN CAUSE RISK OF ELECTRICAL SHOCK.
IMPORTANT SAFETY INSTRUCTIONS
NOT FOR OUTDOOR INSTALLATIONS
IF YOU HAVE RECEIVED THESE PARTS FOR AN OUTDOOR
INSTALLATION, PLEASE CONTACT YOUR LOCAL REPRESENTATIVE.
INDOOR HARDWIRE INSTALLATION INSTRUCTIONS
INDOOR DIRECT WIRE INSTALLATION OPTIONS
DL-AC-FLEX-HW-RADJ
Integral heatsink coverplate
with SURGE SUPPRESSOR and 90°
connection for ¾” rigid raceway
Asee page 3 Bsee page 4 Csee page 7
DL-AC-FLEX-HW-CNDT
Integral heatsink coverplate with
SURGE SUPPRESSOR and output
WRFRQQHFWLRQIRUôµÁH[LEOH
aluminum conduit
DL-AC-FLEX-HW
Integral heatsink coverplate with
SURGE SUPPRESSOR
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVER PLATE
Removing the SURGE SUPPRESSOR from integral heatsink cover plate will result in violation of UL requirements, voiding the product warranty
and
RISK OF ELECTRICAL SHOCK AND DAMAGING THE PRODUCT
All electrical connections must be in accordance with local codes, ordinances and the National Electric Code. This product
operates on 120 VACDOZD\VFRQÀUPWKHPD[LPXPZDWWDJHRIWKHOLQHDUVWULSGRHVQRWH[FHHGWKHPD[LPXPZDWWDJHRI
WKHFLUFXLWLWLVFRQQHFWHGWR,I\RXDUHXQIDPLOLDUZLWKPHWKRGVRILQVWDOOLQJHOHFWULFDOZLULQJVHFXUHWKHVHUYLFHVRIDTXDOLÀHG
licensed electrician.
'RQRWFRYHUWKLVSURGXFWDVWKHFRYHULQJPD\FDXVHWKHÁH[LEOHOLJKWWRRYHUKHDWDQGPHOWRULJQLWH
'RQRWRSHUDWHZLWKWKHÁH[LEOHOLJKWZKLOHDWWDFKHGWRSODVWLFVSRRORUWLJKWO\FRLOHG([FHVVKHDWPD\PHOWWKHVSRRO
and/or strip light.
'RQRWSXQFWXUHFXWVKRUWHQRUVSOLFHWKHÁH[LEOHOLJKWLQJ
'RQRWURXWHWKHFRUGRUÁH[LEOHOLJKWLQJFDEOHWKURXJKZDOOVGRRUVZLQGRZVRUDQ\OLNHSDUWRIWKHEXLOGLQJVWUXFWXUH
• Do not use if there is any damage to the light or cord insulation. Inspect periodically.
'RQRWVXEPHUJHÁH[LEOHOLJKWLQOLTXLGVRUXVHWKHSURGXFWLQWKHYLFLQLW\RIVWDQGLQJZDWHURURWKHUOLTXLGV
'RQRWLQVWDOOQHDUDUHDVZLWKH[SRVXUHWRVDOWZDWHURUFKORULQDWHGZDWHU
6HFXUHWKLVÁH[LEOHOLJKWXVLQJRQO\KDQJHUVRUFOLSVSURYLGHG'RQRWVHFXUHWKLVSURGXFWZLWKVWDSOHVQDLOVRUOLNH
means that may damage the insulation or permanently attach to the building structure.
'RQRWVXEMHFWÁH[LEOHOLJKWLQJWRFRQWLQXRXVÁH[LQJ
'RQRWH[FHHGWKHOHQJWKLQIHHWSHUPLWWHGE\WKHPDUNLQJ
'RQRWLQVWDOOLQHQYLURQPHQWZKHUH/('FKLSVDUHH[SRVHGWRGLUHFWVXQOLJKWDVGDPDJHWRWKHSKRVSKRUZLOORFFXU
RATED 120VOLT AC | 4.95Watt / Foot

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 2 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
MOUNTING OPTIONS
([FOXGLQJPHWDOFKDQQHOPRXQWLQJSOHDVHVHH'/$&)/(;&+0LQVWDOODWLRQVKHHW
'/$&)/(;&+;
'/$&)/(;0&+:
(REQUIRED)
'/$&)/(;0&+:
(REQUIRED)
Illustration is a representation of three sections of DL-AC-FLEX in one run using methods A,B & C
(not to scale, not for installation)
'/$&)/(;0&_'/$&)/(;0&0
'/$&)/(;0&+:
6HFXUHKDUGZLUHFOLSVRQ'/$&)/(;ZLWK
VHOIWDSSLQJVFUHZV7RSUHYHQWVDJJLQJRQ
IDFHGRZQDSSOLFDWLRQZHUHFRPPHQGWR
LQVWDOOKDUGZLUHFOLSVµFPDSDUW
NOTE: 2 hardwire clips (provided) must be
used to secure the beginning and the end of
HDFKVHFWLRQRI'/$&)/(;
Secure channel on wall or other surfaces
ZLWKVHOIWDSSLQJVFUHZVHYHU\LQFKHV
NOTE: 2 hardwire clips (provided) must
be used to secure the beginning and the
HQGRIHDFKVHFWLRQRI'/$&)/(;
Secure mounting U clips on wall or other
VXUIDFHVZLWKVHOIWDSSLQJVFUHZVHYHU\
inches.
NOTE: 2 hardwire clips (provided) must be
used to secure the beginning and the end
RIHDFKVHFWLRQRI'/$&)/(;
FACE-DOWN OR VERTICAL APPLICATIONS
0RXQWLQJRSWLRQ$ZLWKFKDQQHOLVUHFRPPHQGHG
FACE-UP OR HORIZONTAL APPLICATIONS
0RXQWLQJRSWLRQ$%&DUHDOODSSURSULDWH
'/$&)/(;&&;;
'/$&)/(;&&;;
6in
15cm
6in/15cm
Per UL safety requirements'/$&)/(;0&+:PRXQWLQJ
clips must be used in mounting at the beginning and the
HQGRIHDFKVHFWLRQRI'/$&)/(;LQDUXQ
A
A
B
C
BC
++ +
['/$&)/(;0&+:3URYLGHG
+
'/$&)/(;0&+:
INCLUDED
'/$&)/(;0&+:
Required 2 per section
['/$&)/(;0&+:3URYLGHG
+
'/$&)/(;&+;
6in/15cm
['/$&)/(;0&+:3URYLGHG
+
'/$&)/(;0&_'/$&)/(;0&0
6in
15cm
6in
15cm
'/$&)/(;0&_0&0
Allow 1/8” (3.2mm) clearance

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 3 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
A
INSTALLING DL-AC-FLEX-HW
$&)OH[LEOH/LQHDU6WULS
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
beginning installation by switching circuit breaker
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
HARDWARE
(INCLUDED)
,1'((3%2;
0,1µ'(37+
6-7&25'675$,15(/,()%86+,1*
Single Use Parts
Permanently locks on SJT cord.
0DNHVXUHWRGRXEOHFKHFN
length before locking bushing
on cord.
Any attempt to remove the
bushing will destroy the part. WIRE NUTS 02817,1*
SCREWS
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
287387&$%/(
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
,1387&$%/(
(120V AC Input)
SURGE SUPPRESSOR
287387&$%/(
:+,7(+27
%/$&.1(875$/
167V DC Output
SURGE SUPPRESSOR
INPUT WIRES
'28%/('
+2/(
02817,1*
SCREWS
685*(6835(6625287387&$%/(
SURGE SUPPRES
,QWHJUDO+HDWVLQN3ODWH
6833/<:,5(6
%/$&.+27
:+,7(1(875$/
GREEN or COPPER (GROUND)
%/$&.+27
:+,7(1(875$/
GREEN (GROUND)
&211(&7685*(68335(6625,1387:,5(6:,7+6833/<:,5(6
1. Connect Supply Wires to SURGE SUPPRESSOR input wires: BLACK TO BLACK AND WHITE TO WHITE,
and green or copper to green.
2. Secure all connections with wire nuts (not included).
3. Determine length needed outside of integral heatsink plate, secure included SJT cord strain relief
RQWR$&)/(;LQSXWFDEOHZLWKDSDLURISOLHUVDQGSXVKLWLQWRLQWHJUDOKHDWLQNSODWH·V'28%/('
hole.
OPTIONAL: WRVKRUWHQ$&)/(;LQSXWFDEOHPHDVXUHDQGFXW$&)/(;LQSXWFDEOHWRGHVLUHGOHQJWK
DQGUHFRQQHFW$&)/(;LQSXWFDEOHZLWK685*(68335(6625RXWSXWFDEOHBLACK TO BLACK AND
WHITE TO WHITE inside of heatsink coverplate, secure connection with wire nuts (not included).
5. &DUHIXOO\WXFNDOOFRQQHFWHGZLUHVLQVLGHWKHMXQFWLRQER[6HFXUHLQWHJUDOKHDWVLQNFRYHUSODWH
WRMXQFWLRQER[ZLWKPRXQWLQJVFUHZVQRWLQFOXGHGPDNLQJVXUHWRQRWSLQFKDQ\ZLUHVRUZLUH
nuts.
SJT Cord Strain Relief
NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVERPLATE.
Doing so is in direct violation to UL requirements and will void the warranty of the product.
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
A
RATED 120VOLT AC | 4.95Watt / Foot
$&)/(;,1387&$%/(
&RQQHFWVWR685*(68335(6625287387&$%/(
%/$&.WR%/$&.
:+,7(WR:+,7(

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 4 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
B1
B2 B4 B5
B3
INSTALLING DL-AC-FLEX-HW-CNDT
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
beginning installation by switching circuit breaker
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
HARDWARE FOR
INSTALLATION (INCLUDED)
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
SURGE SUPPRESSOR
287387&$%/(
SURGE SUPPRESSOR
287387&$%/(
µ0&$&
&21'8,7%86+,1*
µ0&$&
CONNECTOR
µ0&$&)/(;,%/(
&21'8,7$66(0%/<
$&)/(;,1387&$%/(
$&)/(;
,1387&$%/(
$&)/(;
,1387&$%/( SJT CORD
STRAIN RELIEF
µ0&$&
)OH[LEOH&RQGXLW
µ0&$&
)OH[LEOH&RQGXLW
3XVKLQ
Connector
µ0&$&
386+,1
CONNECTOR
SJT CORD
STRAIN RELIEF
µ0&$&
)/(;,%/(
CONDUIT
µ0&$&
CONDUIT
%86+,1*
B1 8QGRWKHZLUHQXWVGLVFRQQHFWLQJ$&)/(;LQSXW&$%/(
B2 &RQQHFWµ0&$&SXVKLQFRQQHFWRUWRDµ0&$&ÁH[LEOHFRQGXLWSUHPHDVXUHDQG
cut conduit to desired length).
B3)HHG$&)/(;LQSXWFDEOHWKURXJKµ0&$&ÁH[LEOHFRQGXLWDVVHPEO\LQVHUWDµ0&$&
FRQGXLWEXVKLQJLQWRWKHHQGRIµ0&$&ÁH[LEOHFRQGXLWDVVHPEO\
B4)HHG$&)/(;LQSXWFDEOHEDFNWKURXJKKROHLQKHDWVLQNSODWH&RQQHFWµ0&$&ÁH[LEOH
FRQGXLWWRµ0&$&FRQQHFWRUDOUHDG\PRXQWHGRQLQWHJUDOKHDWVLQNSODWH7LJKWHQVHWVFUHZ
RQµ0&$&FRQQHFWRURQIDFHSODWHWRVHFXUHWKHFRQQHFWLRQ
B5 3XOOWKURXJK$&)/(;LQSXWFDEOHVRWKDWQRFDEOHLVH[SRVHGSDVWWKHµ0&$&SXVKLQ
FRQQHFWRU6HFXUHSURYLGHG6-7FRUGVWUDLQUHOLHIRQ$&)/(;LQSXWFDEOHZLWKSOLHUVRUFODPSLQJ
WRRO5HFRQQHFW$&)/(;LQSXWFDEOHZLWK685*(6835(6625RXWSXWFDEOHBLACK TO BLACK AND
WHITE TO WHITE.
WIRE NUTS
02817,1*6&5(:6
,1'((3%2;
0,1µ'(37+
B
$&)/(;,1387&$%/(
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
,1387&$%/(
(120V AC Input)
SURGE SUPPRES
,QWHJUDO+HDWVLQN3ODWH
*NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVERPLATE.
Doing so is in direct violation to UL requirements and will void the warranty of the product.
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
SURGE SUPPRESSOR
287387&$%/(
:+,7(+27
%/$&.1(875$/
167V DC Output
RATED 120VOLT AC | 4.95Watt / Foot

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 5 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
B6
INSTALLING DL-AC-FLEX-HW-CNDT (Continued)
INPUT WIRES
02817,1*
SCREWS
SURGE SUPPRESSOR* ,QWHJUDO+HDWVLQN3ODWH
6833/<:,5(6
%/$&.+27
:+,7(1(875$/
GREEN or COPPER (GROUND)
%/$&.+27
:+,7(1(875$/
GREEN (GROUND)
&211(&7685*(68335(6625,1387:,5(6:,7+6833/<:,5(6
1. Connect hot supply wire (BLACK) to hot input wire (BLACK).
2. Connect neutral supply wire to (WHITE) neutral input wire (WHITE).
3. Connect supply ground wire (green or bare copper) to ground input wire (green).
4. Secure all connections with wire nuts (not included).
&DUHIXOO\WXFNDOOFRQQHFWHGZLUHVLQVLGHWKHMXQFWLRQER[6HFXUHLQWHJUDOKHDWVLQNFRYHUSODWH
WRMXQFWLRQER[ZLWKPRXQWLQJVFUHZVQRWLQFOXGHG), making sure to not pinch any wires or wire
nuts.
*NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVERPLATE.
Doing so is in direct violation to UL requirements and will void the warranty of the product.
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
B
$&)/(;,1387&$%/(
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
,1387&$%/(
(120V AC Input)
SURGE SUPPRESSOR*
,QWHJUDO+HDWVLQN3ODWH
SURGE SUPPRESSOR
287387&$%/(
:+,7(+27
%/$&.1(875$/
167V DC Output

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 6 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
B7
INSTALLING DL-AC-FLEX-HW-CNDT
(EXTENDING CORD LENGTH WITH SPLICE BOX)
for length requirements longer than 20 feet
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
beginning installation by switching circuit breaker
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
HARDWARE FOR INSTALLATION
(INCLUDED)
WIRE NUTS 8/5$7('63/,&(%2;
:,7+&29(5 SJT CORD
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
(;7(1'('6-7&25'QRWLQFOXGHG
&RQQHFWVWR$&)/(;,1387&$%/(
%/$&.WR%/$&.
:+,7(WR:+,7(
02817,1*6&5(:6
63/,&(%2;&29(5
PLATE
SJT STRAIN RELIEF
(Provided)
$&)/(;,1387&$%/(
8/5$7('63/,&(%2;
µ0&$&
&21'8,7%86+,1*
µ0&$&
)/(;,%/(&21'8,7
µ0&$&
)/(;,%/(&21'8,7
3/8” CONDUIT
CONNECTOR
PREPARE SPLICE BOX TO USE
3XQFKRXWWZRNQRFNRXWVRQDVSOLFHER[DQGFRQQHFWWZRµFRQGXLWFRQQHFWRUVWRWKH
VSOLFHER[RQHIRULQSXWFRQQHFWLRQDQGRQHIRURXWSXWFRQQHFWLRQ
CONNECT AC-FLEX INTO SPLICE BOX
2. Follow STEPS B2 and B3WKHQFRQQHFWµ0&$&ÁH[LEOHFRQGXLWDVVHPEO\WRRQHRIWKH
VSOLFHER[·VµFRQGXLWFRQQHFWRUVWLJKWHQVHWVFUHZRQµFRQGXLWFRQQHFWRUWRVHFXUHWKH
connection.
3. Reference STEP B5WRDWWDFKSURYLGHG6-7VWUDLQUHOLHIRQ$&)/(;LQSXWZLUH
CONNECT EXTENDED SJT CORD INTO SPLICE BOX AND INTEGRAL HEATSINK PLATE
)HHG6-7FRUGWKURXJKµÁH[LEOHFRQGXLWLQVHUWµFRQGXLWEXVKLQJRQERWKHQGVRIµ
ÁH[LEOHFRQGXLW&RQQHFWµÁH[LEOHFRQGXLWDVVHPEO\WRµFRQQHFWRUVRQVSOLFHER[DQGRQ
integral heatsink plate, tighten set screws to secure all connections.
CONNECT EXTENDED SJT CORD TO AC-FLEX INPUT CABLE
&RQQHFW%/$&.DQG:+,7(ZLUHVIURPH[WHQGHG6-7FRUGDQG$&)/(;LQSXWFDEOHVHFXUHDOO
FRQQHFWLRQVZLWKZLUHQXWV8VHPRXQWLQJVFUHZVWRVHFXUHFRYHUSODWHWRVSOLFHER[
µ0&$&
)/(;,%/(
CONDUIT
µ0&$&
CONDUIT
%86+,1*
3/8”
CONDUIT
CONNECTOR
SJT CORD
STRAIN RELIEF
*NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVERPLATE.
Doing so is in direct violation to UL requirements and will void the warranty of the product.
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
B
$&)/(;,1387&$%/(
$&)/(;,1387&$%/(
SURGE SUPPRESSOR
,1387&$%/(
(120V AC Input)
SURGE SUPPRESSOR*
,QWHJUDO+HDWVLQN3ODWH
SURGE SUPPRESSOR
287387&$%/(
:+,7(+27
%/$&.1(875$/
167V DC Output
RATED 120VOLT AC | 4.95Watt / Foot

www.jescolighting.com
Tech Support: 855.592.0029
Installation sheet subject to change without prior notice.
15 Harbor Park Drive
Port Washington, NY 11050
Main Line: 800.527.7796
Fax Line: 855.265.5768
219 South 6th Ave
City of Industry, CA 91746
Main Line: 855.654.0110
Fax Line: 626.333.2955
Designed, Developed and
Assembled in the U.S.A
JW 02/01/2019
© 2015 JESCO LIGHTING GROUP, LLC
Page 7 of 9
7\SH
3URMHFW
&DWDORJ1R
'/$&)/(;,1'225$33/,&$7,216
,1),1$/(')/(;,%/(/,1($5 3$7(1712
3$7(1712
$&)/(;,%/(/,1($5675,3
C1 C2
INSTALLING DL-FLEX-HW-RADJ
TURN OFF ELECTRICITY
DWPDLQIXVHER[RUFLUFXLWEUHDNHUER[EHIRUH
beginning installation by switching circuit breaker
off or removing fuse.
0,1&6833/<&21'8&7256
HARDWARE FOR INSTALLATION
(NOT INCLUDED)
,1'((3%2;
0,1µ'(37+ UL LISTED
µ5$&(:$<
WIRE NUTS
CONSULT A QUALIFIED ELECTRICIAN TO
ENSURE CORRECT BRANCH CIRCUIT
ON OFF
1
TURN OFF ELECTRICITY
AT MAIN FUSE BOX
$&)/(;
02/'('
CONNECTOR
%86+,1*
5$&(:$<
%$6(%5$&.(7
C2 CONNECT RACEWAY ON TO AC-FLEX INPUT CORD
0HDVXUHDQGFXWPHWDOUDFHZD\WRGHVLUHGOHQJWh.
0RXQWPHWDOUDFHZD\·VEDVHEUDFNHWWRZDOOSHUSURGXFW·VLQVWUXFWLRQV3,DFHµEXVKLQJRQWKH
HQGRI$&)/(;PROGHGFRQQHFWRUFDUHIXOO\VQDSRQUDFHZD\WREDVHEUDFNHW
3XOOWKURXJK$&)/(;LQSXWFDEOHVRWKDWQRFDEOHLVH[SRVHGSDVWWKHHQGRIUDFHZD\6HFXUH
SURYLGHG6-7FRUGVWUDLQUHOLHIRQ$&)/(;LQSXWFDEOHZLWKSOLHURUFODPSLQJWRRO
&DUHIXOO\WXFNDOOFRQQHFWHGZLUHVLQVLGHWKHMXQFWLRQER[6HFXUHLQWHJUDOKHDWVLQNFRYHUSODWHWR
MXQFWLRQER[ZLWKPRXQWLQJVFUHZVQRWLQFOXGHG), making sure to not pinch any wires or wire nuts.
µ%86+,1*
SURGE
SUPPRESSOR
INPUT WIRES
$&)/(;,1387&$%/(
6833/<:,5(6
%/$&.+27
:+,7(1(875$/
GREEN or COPPER (GROUND)
%/$&.+27
:+,7(1(875$/
GREEN (GROUND)
02817,1*
SCREWS
SURGE SUPPRESSOR
287387&$%/(
C1 CONNECT SURGE SUPPRESSOR INPUT WIRES WITH SUPPLY WIRES
1. Connect hot supply wire (BLACK) to hot input wire (BLACK).
2. Connect neutral supply wire (WHITE) to neutral input wire (WHITE).
3. Connect supply ground wire (green or bare copper) to ground wire input wire (green).
4. Secure all connections with wire nuts (not included)
*NOT FOR OUTDOOR INSTALLATION
*DO NOT REMOVE SURGE SUPPRESSOR FROM INTEGRAL HEATSINK COVERPLATE.
Doing so is in direct violation to UL requirements and will void the warranty of the product.
INCORRECT BRANCH CIRCUIT CONNECTION
WILL VOID THE WARRANTY OF THE PRODUCT.
C
$&)/(;,1387&$%/(
$&)/(;,1387&$%/(
SURGE
SUPPRESSOR
,1387&$%/(
(120V AC
Input)
SURGE SUPPRESSOR*
,QWHJUDO+HDWVLQN3ODWH
SURGE SUPPRESSOR
287387&$%/(
:+,7(+27
%/$&.1(875$/
167V DC Output
RATED 120VOLT AC | 4.95Watt / Foot
&RQQHFWVWR685*(68335(6625287387&$%/(
%/$&.WR%/$&.
:+,7(WR:+,7(
Table of contents
Other Jesco Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Lyyt
Lyyt 155.010UK installation guide

Wicked Warnings
Wicked Warnings 2 Series Installation and operation instruction

Blizzard Lighting
Blizzard Lighting Rocklite RGBAW user manual

Lutron Electronics
Lutron Electronics CTCL-153PDH-WH owner's manual

NA-DE
NA-DE 20024 instruction manual

Daintree
Daintree GE Tetra Atom installation guide

Hayward
Hayward AquaRite AQR15 owner's manual

LITESHEET
LITESHEET BriteCor AC Direct BWA installation manual

Rotolight
Rotolight AEOS user manual

Douglas Lighting Controls
Douglas Lighting Controls Dialog WIR-3110 user manual

Whelen Engineering Company
Whelen Engineering Company 4500 Series installation guide

Satco
Satco NUVO 67-110 Installation and safety instructions