Operating Instructions and Parts Manual
Surface Mounted High Speed Hand Dryer
General Safety Information
This product is intended for installation by a
qualied service person. Use AWAG No. 16 solid
conductor for wiring.
Failure to properly ground unit could result in
electrical shock and/or death.
Disconnect power at the service breaker before
installing or servicing.
NOT FOR HOUSEHOLD USE - MAY CAUSE BURNS
All units must be supplied with a 3-wire service. The
ground wire must be connected with the dryers
back plate.
WARNING NOTE: Do not install dryer over wash basin.
Type Y attachment
If the power supply cord is damaged, it must be
replaced by the manufacturer or its service agent or a
similar qualied person in order to avoid a hazard.
Means for disconnection must be incorporated in the
xed wiring in accordance with the wiring rules.
Installation
Installation must be carried out only by a qualied
electrician
Installation must be carried out in accordance with the
current edition of the local wiring regulations code
having jurisdiction. Installation should be performed
2. Place template against wall at desired height
(see mounting height recommendations) and mark
locations of 4 mounting holes and wire service entry at
knockout (KO) location.
NOTE: For two or more dryers, dryers should be no
closer than 24 inches (610 mm) on centre.
3. Remove and retain 2 cover screws.
4. Connect supply wires to terminal block where
indicated and connect ground wire to baseplate with
ground screw.
Connections:
a. Connect the live wire (black) to the terminal
block marked “L”.
b. Connect the neutral wire (white) to the terminal
block marked “N”.
Note that the colour of live and neutral wires depends
on voltage of supply service.
5. Replace cover screens. Do not over-tighten.