1.The power supply is AC supply.
2.Please confirm the rated voltage and frequency according to the nameplate when using it.
3.The motor will jog in operation, please do not proceed to the next step until it complete.
4.During operation, the effective interval of the transmitter button operation is 10 seconds.
If there is no effective transmitter operation for more than 10 seconds, it will automatically
exit the current mode.
5.The motor can be paired with max 10 controllers.
6.Upper&Lower limits cannot be set at the same position, limits saved even power off.
7.The motor runs constantly for at 6mins max without any other operation.
8.Do not lift the motor by grabbing the wire or antenna.
220V/50Hz
Power wire
RF Antenna Zigbee Antenna
H button
Motor Head Button(H)
Motor head button (H) functions
Functions Operation Jogging
time
LED lamp
flickers Note
Control the UP/STOP/
DOWN of the Shade Short press / /
Adding/Removing
Controller Hold for 2s Jog*1 Flicker*1
Flicker*2
Flicker*3
Flicker*4
Hold for 6s Jog*2
Direction Reverse Hold for 10s Jog*3
Reset Hold for 16s Jog*4 All settings deleted
LED
AC Tubular Motor with Zigbee
User Manual
Working temperature
-10℃
55℃
LED
Stop
CH-
Fav
Up
CH+
Down
Prg
Remote Controller Buttons Power Options
Models & Parameters (for details about other parameters, see the product nameplate)
JCA
AC Motor
35
Tube Diameter: 35 mm
S
S:Standard Torque: 10Nm
100 17
Speed: 17Rpm
E
E: Electric limit 230V/50Hz
EL: Electric limit 110V/60Hz
Built-in Zigbee module
Z
Green/Yellow Wire: E
110V/60Hz
White Line: N
Red Line: L
Green Line: E
Blue Line: N
Brown Line: L
Up or Down Fix upper point Up & Fav x2s Upper
limit set
Fix lower point Lower
limit set
Note: Upper&Lower limits cannot be set at the same point.
Before limits set, the motor will run in one-touch mode by pressing Up or Down,
hold Up or Down for 2s, motor runs in constant-touch mode.
Once limits set, press Up or Down, motor runs in constant-touch mode.
Jog x2
Up or Down Down & Fav x2s Jog x2
&
&
or
or
Stop
Note: When motor in one-touch mode, hold Up or Down for more than 2s, it will run in
constant-touch mode.
Constant-touch ------>One-touch
Same operation can toggle from one-touch to constant -touch mode.
Prg Jog x1 Jog x1 Stop Jog x1
OK
P
Fix Fav.
position
Fav. position
set
Setting
Shade is at
Fav. position
Fav. position
Cancel
Cancelling
Up or Down Fav & Stop x2s Jog x2
Fav & Stop x2s Jog x1
&
&
or
Fast get to the Fav. point
Fav
Note: The operation should be done within 4mins.
Up &Fav x6s Up or Down Fix new
upper limit
OK
Fix new
lower limit
Adjust Upper limit
Adjust Lower limit
Jog x1 Up &Fav x2s
Jog x2
Down &Fav x6s Jog x1 Up or Down Down &Fav x2s
Jog x2
OK
&&
or
& &
or
Remove a single controller
Prg
OK
Prg on
existing A
Stop on B
(to remove)
H button x2s Jog x1 Jog x1
Jog x1 Prg on
existing A
Jog x1 Jog x1
P
P P
H button
Remove all controllers:
Prg Down
All controllers removed
Jog x1 Prg Jog x1 Jog x1
P P
Prg Jog x1 Stop Jog x1 Jog x1Prg
P P
Zigbee Connecting
01 Product Info
02 Caution!
03 Instructions
a.Pairing Motor with Controller
b.Direction Reverse
c.Upper&Lower Limits Setting
d.One-touch/Constant-touch Mode
e.Setting and Cancelling Favorite Position
f.Hot key to the Fav. Position
g.Adjusting Upper & Lower Limits
Note: Pairing can not be done under group channel or 0 channel.
h.Removing Controllers
Remove controller B via pre-existing controller A
Controller B removed
Limits cancelled
Note: It is forbidden to run the motor if installed into the shade without limits.
Limits should be set immediately to protect the shade.
Note: All the settings are saved even controllers removed(limits set are saved).
Controller A/B are already paired to motor.
Note: The Fav. position setting only can be done after upper&lower limits set.
i.Cancelling Limits
Can only operate after
the limits are set
Operation needs be
done within 10s
Entering Zigbee
connection mode
All settings saved after
direction reversed
After motor is powered on for more than 10s
Zigbee connecting
Hx6s Blue LED flicker
Blue LED flicker
H button
Jog x2
Release the
button
LED
Way 2:
Prg Jog x1 Jog x1
Down Up Jog x1
Zigbee connecting
LED
LED
P
*Connection requirement
Make sure the Wi-Fi module and smart phone be connected to the same Wi-Fi network.
The smart phone needs to connect to Wi-Fi network and turn on the Bluetooth function first
05 Troubleshooting
04 Zigbee Connecting
Wi-Fi
①Download APP
②Add Device
Fault Cause Solution
The motor does not run or
start slowly
1.Low voltage
2.Wrong wire connection
3.Overloading
4.Wrong installation
1.Adjust the voltage to rated
data
2.Correct the wire connection
3.Put the suitable weight for
roller shade
4.Reinstall the tubular motor
The motor suddenly stop The motr has exceeded termal
overheat protection (4 minutes)
Wait for the motor to cool
down for approximately 20
minutes
The motor makes a
strange noise when it runs
1.The crown and drive adapter
are not well adapterd to tube
2.The driving tube is too long,
cused the brackets are too
tightly
1.Change correct size crown
and drive adapter
2.If idler is active, make
driving tube shorter to avoid
the tight status

This manual suits for next models

1

Other Jiecang Engine manuals

Jiecang JCC50SLEU User manual

Jiecang

Jiecang JCC50SLEU User manual

Jiecang JCA35SEW01 User manual

Jiecang

Jiecang JCA35SEW01 User manual

Jiecang JCC50STEW User manual

Jiecang

Jiecang JCC50STEW User manual

Popular Engine manuals by other brands

Toro GREENSMASTER 3100 installation instructions

Toro

Toro GREENSMASTER 3100 installation instructions

ECOTRONS DLE120 installation manual

ECOTRONS

ECOTRONS DLE120 installation manual

Nice E QUICK M 426 Instructions and warnings for installation and use

Nice

Nice E QUICK M 426 Instructions and warnings for installation and use

Kohler CS10 owner's manual

Kohler

Kohler CS10 owner's manual

Kubota D1503-M-E3 Operator's manual

Kubota

Kubota D1503-M-E3 Operator's manual

Toshiba TB9051FTG manual

Toshiba

Toshiba TB9051FTG manual

Perkins 1206E-E70TTA Operation and maintenance manual

Perkins

Perkins 1206E-E70TTA Operation and maintenance manual

RAAMDECORATIE MOTION CM-03 manual

RAAMDECORATIE

RAAMDECORATIE MOTION CM-03 manual

ZIEHL-ABEGG ZA top SM160.40B/S Original operating instructions

ZIEHL-ABEGG

ZIEHL-ABEGG ZA top SM160.40B/S Original operating instructions

Mitsubishi 4G6 Series 1991 Workshop manual

Mitsubishi

Mitsubishi 4G6 Series 1991 Workshop manual

NetGain Motors HyPer 9 IS user manual

NetGain Motors

NetGain Motors HyPer 9 IS user manual

Perkins 2206F-E13TA Operation and maintenance manual

Perkins

Perkins 2206F-E13TA Operation and maintenance manual

Shanghai Diesel Engine SC9DF Operation and maintenance manual

Shanghai Diesel Engine

Shanghai Diesel Engine SC9DF Operation and maintenance manual

Scania DC09 installation manual

Scania

Scania DC09 installation manual

Tecumseh HSK35 Operator's manual

Tecumseh

Tecumseh HSK35 Operator's manual

Kohler Magnum 8 HP owner's manual

Kohler

Kohler Magnum 8 HP owner's manual

Emerson Leroy-Somer FFB Series Maintenance Guide

Emerson

Emerson Leroy-Somer FFB Series Maintenance Guide

Autonics MD5 Series instruction manual

Autonics

Autonics MD5 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.