PCU-220 User Guide v. 5.10
Page 9
©2023 JMA Wireless. All rights reserved. This document contains proprietary and confidential information. All products, company names,
brands, and logos are trademarks™or registered® trademarks of their respective holders. All specifications are subject to change without
notice. Revised: August 4, 2023 +1 315.431.7100 customerservice@jmawireless.com
Antenna Systems
PCU-220 GUI User Guide
Version 5.10
8. Calibrate the RET by clicking
9. Set/get the tilt within the min/max range:
10. Verify that the results show “Success” and verify that there are no alarms by
clicking under “Alarms.” See Table 2 for alarm lists.
11. Configure the operator data such as Antenna Serial#, Base Station Id, and Sector
Id, etc. Click Set for each item to write to the RET.
12. Save a report using for the devices from the ALD list in the Properties window.
•Name the report and save.
•Allow time for the report to generate. will show “Running” while
each motor is being accessed to get the data for the report.
•A report will be generated for ALL ALDs connected –see Figure 11 for a
report sample.
13. Alarms are listed below in Table 2 with recommended actions.
Basic alarm Reason Corrective action
Not calibrated Antenna is in an un-calibrated
state. This can be caused by ACF
download, power cycle during
motor movement, or an invalid tilt
was set.
Run the Calibration sequence.
Busy The RET is busy processing
another command. Allow the active command to
complete.
Motor/actuator jam The RET was unable to move
properly during a Calibration
RET.
2. Run the Calibration sequence.
3. If the problem persists, contact
technical support.
Out of range An invalid tilt value was set. 1. Run Calibration sequence.
2. Set the tilt to a valid number
within the range shown for
max/min tilt.
Read only User trying to write data to a read-
only field. No corrective action. Fields cannot
be changed by user.
Table 2 –Alarm list and corrective actions