Jobar HSN7239 User manual

FOR NON-MEDICAL PERIODIC CHECK OF BLOOD OXYGEN
SATURATION LEVELAND PULSE RATE AT HOME, AND FOR SPORT
AND RECREATIONAL USES SUCH AS MOUNTAIN CLIMBING, HIGH
ALTITUDE ACTIVITIES AND RUNNING.
THIS FINGERTIP OXYGEN METER IS NOT INTENDED FOR MEDICAL
DIAGNOSTIC OR TREATMENT USE.
1. Do not use if in cardiac arrest or in shock.
2. The Oxygen Meter has no alarms and is not intended for continuous
monitoring.
3. SpO2measurements may be adversely affected in the presence of
strong light. Shield the sensor area with a cloth if necessary.
4. Fingernail polish or false fingernails may cause inaccurate SpO2
readings.
5. Inaccurate measurements may be caused by immersing the sensors
in liquid.
6. Excessive movement may cause inaccurate readings.
7. Keep away from small children as this device has small parts that
may pose as a choking hazard.
Follow local ordinances for disposal and recycling of the device,
components and batteries.
1. Fingertip Oxygen Meter is a portable non-invasive, spot-check for
blood oxygen saturation (SpO2) and pulse rate.
2. The Oxygen Meter requires no routine calibration other than
replacement of batteries.
3. Operation of the product is simple and convenient.
4. The product is small in volume, light in weight and convenient to
carry.
5. Power consumption of the product is low and two AAA batteries is
enough for it to operate continuously for 24 hours.
6. A low voltage warning will be indicated on the LCD display when
battery power is low, replace batteries immediately to avoid
inaccurate measurements.
7. The product will automatically be powered off when no finger is
inserted into the product within 8 seconds.
Battery
1. Slide the battery cover and remove.
2. Insert twoAAA batteries with correctly aligned polarities.
3. Replace the battery cover.
Battery polarities should be correctly aligned. Otherwise, you
may damage the device.
Please remove the batteries if the Oxygen Meter will not be
used for a long time.
Lanyard
1. Thread the thin end of the lanyard through the loop at the top of the
Oxygen Meter.
2. Thread the thick end of the lanyard through the thin end, and then
tighten to secure.
1. Clamp one finger fully into the rubber hole of the Oxygen Meter with
nail facing upwards.
2. Press the power switch on the front panel to start measurement.
4. Sit down and relax your whole body while the measurement is being
taken.
5. Read corresponding data on the display screen.
The pulse rate bar graph displays your pulse beat. The height of the bar
graph shows the strength of your pulse.
When your finger is inserted into the Oxygen Meter, your nail must be
facing upwards.
1. Replace the batteries immediately when the low voltage warning
lights up.
2. Clean the surface and the medical rubber of the Oxygen Meter
before usage.
3. Remove the batteries inside the battery compartment if the Oxygen
Meter will not be operated for a long time.
4. It is best to store the product in a place where temperature is
between -20°C ~ 60°C (-4°F ~ 140°F).
5. It is recommended that the product should be kept in a dry
environment at all times. A damp environment may decrease its
durability or even may damage the product.
1. Lanyard
2. 2 x AAA Batteries (not included)
3. Instruction Sheet
Power Switch
Pulse Rate Bargraph
Pulse Rate
Oxygen Saturation Level
Cautions
Intended Use
Installation
JB# 5892
Maintenance & Storage
Instructions
Product Accessories
Properties
OXYGEN METER
Instruction Sheet
Item#HSN7239
Installation- (Cont.)
Problem
Possible Reason
Solution
The SpO2and
Pulse Rate can
not be
displayed
normally
1. The finger is not properly
positioned.
2. Your SpO2is too low to be
detected.
1. Place the finger properly
and try again.
2. Try again; Go to a
hospital for a diagnosis if
you are sure the device
works all right.
The SpO2and
Pulse Rate are
not displayed
stably
1. The finger is not placed
inside deep enough.
2. The finger is shaking or
you are moving.
1. Place the finger properly
and try again.
2. Keep the user calm and
at ease.
The device can
not be turned
on
1. The batteries are drained
or almost drained.
2. The batteries are not
inserted properly.
3. The device is
malfunctioning.
1. Change batteries.
2. Reinstall batteries.
3. Please contact the local
service center.
The display
shuts off
suddenly
1. The device will power off
automatically when it gets no
signal within 8 seconds.
2. The batteries are almost
drained.
1. Normal.
2. Change batteries.
Symbol
Description
To indicate the "ON" position for a part of equipment.
Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury to the user
or patient or damage to the equipment or other property.
SpO2
The pulse oxygen saturation (%)
Pulse rate
The equipment type is BF (IEC60601-1:2005)
Refer to instruction manual/booklet
No SpO2 Alarms
IPX1
Grade of waterproof
Serial number
The marking of electrical and electronics devices according
to Directive 2012/19/EU.
The device, accessories and the packaging have to be
disposed of waste correctly at the end of the usage.
Power low indicator (Please replace batteries when you
see this symbol)
Display : Backlit LCD Display;
SpO2Measuring Range: 70% ~ 100%;
Pulse Rate Measuring Range: 30 pulses/min ~ 199 pulses/min;
Pulse Intensity Display: Columniation display
Power Requirements: 2 ×1.5V AAA alkaline battery (or rechargeable
battery).
Resolution: 1% for SpO2and 1 bpm for Pulse Rate.
Measurement Accuracy: ±2% in stage of 80% ~ 100% SpO2, ±3% in
stage of 70% ~ 79% SpO2, and meaningless when stage being smaller
than 70%; ±2 bpm or ±2% (select larger) for Pulse Rate.
The Fingertip Oxygen Meter will power off if no finger is inserted into it
within 8 seconds.
Specifications
Statement
This manual and product are not meant to be a substitute for advice
provided by your doctor. If you have a medical problem, promptly
consult your healthcare provider.
Limited Warranty
nt
The unit is warranted to be free of manufacturing defects in the
workmanship and materials for a period of one year from the date
listed on the purchase record, and when used in accordance with
instructions provided with the unit.This warranty covers parts and labor
only under normal operation.
Please note: warranty does not cover damage caused by, including
but not limited to: misuse or abuse, accident; the attachment of any
unauthorized accessory; alteration to the product; improper
installation; unauthorized repair or modification; improper use of
electrical/power supply; dropped product; failure to follow required
maintenance and safekeeping; transportation damage or use in a
professional environment.
To obtain defect warranty service, consumer must
(a) contact Jobar International Inc via email at info@jobar.com or call
at (310) 222-8682 x 306 and request a ReturnAuthorization (RA)
number;
(b) provide proof of purchase within the warranty period in the form of
a bill of sale or receipted invoice;
(c) ship the unit freight prepaid, in either its original packaging or
packing affording an equal degree of protection.
Note: if we receive your item back and it does not meet our return
policy terms, we will not receive the item and will return it to you. This
warranty gives you specific, legal rights and you may also
have rights which vary from State to State.
Thank you,
Customer Service Department
Jobar International, Inc.
Manufactured for:
JOBAR INTERNATIONAL INC.
Carson, CA 90745
Made in China
© 2020

Popular Medical Equipment manuals by other brands

Darco TAS quick start guide

Darco

Darco TAS quick start guide

Empatica EmbracePlus Instructions for use

Empatica

Empatica EmbracePlus Instructions for use

RMS Freedom Edge Instructions for use

RMS

RMS Freedom Edge Instructions for use

Launchf Creader VIII user manual

Launchf

Launchf Creader VIII user manual

Ofa Bamberg memory men Instructions for use

Ofa Bamberg

Ofa Bamberg memory men Instructions for use

Anelto HomeAssure 4G quick start guide

Anelto

Anelto HomeAssure 4G quick start guide

Qardio QardioCore Patient instructions

Qardio

Qardio QardioCore Patient instructions

Pic Solution Mister 8 Instructions for use

Pic Solution

Pic Solution Mister 8 Instructions for use

MX HEALTH MX86001 user manual

MX HEALTH

MX HEALTH MX86001 user manual

Beurer medical PO 30 instruction manual

Beurer medical

Beurer medical PO 30 instruction manual

Chattanooga LIGHTFORCE FXi Instructions for use

Chattanooga

Chattanooga LIGHTFORCE FXi Instructions for use

Operative Experience TCCS Plus quick start guide

Operative Experience

Operative Experience TCCS Plus quick start guide

LABORIE Solar Blue Service & installation manual

LABORIE

LABORIE Solar Blue Service & installation manual

Nasco LIFE FORM AUSCULTATION TRAINER user guide

Nasco

Nasco LIFE FORM AUSCULTATION TRAINER user guide

Hologic selenia dimensions user guide

Hologic

Hologic selenia dimensions user guide

Stryker Prime Series Operation manual

Stryker

Stryker Prime Series Operation manual

Kernel KN-5000C manual

Kernel

Kernel KN-5000C manual

KCI V.A.C. ATS Operation and maintenance manual

KCI

KCI V.A.C. ATS Operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.