JuiceGoose RX100-RM User manual

Houston, Texas
p: 713.772.1404
www.juicegoose.com
OWNERS MANUAL
11-09
RX100-RM
Hybrid AC Power Filter
and
Surge Suppressor

FEATURES SUMMARY
RX100-RM features include:
* Less than 1 volt surge potential between neutral and ground
* Less than 10 volt surge potential between neutral and line
* Over voltage and wiring fault shut down
* An all steel Tour Class(tm) chassis
* Eleven 120 volt power outputs
* Fifteen amp, 1200 watt current rating
SAFETY PRECAUTIONS
The RX100-RM is designed to operate with 120VAC, 60 Hz. Opera-
tion with 220 or 240 volts will damage the unit and possibly
cause personal injury.
CAUTIONS
1. The RX100-RM must be grounded to operate. Defeating
the unit’s grounding capability could create a hazard.
2. There are no user serviceable parts inside the RX100-RM.
Do not attempt service yourself. Contact Juice Goose as directed in
this manual if service is required.
3. Do not expose the RX100-RM to moisture. Avoid severe
physical impacts to the unit.
DISCLAIMER
Juice Goose shall under no circumstances be held responsible for
any loss, damage or injury resulting from the use of the RX100-RM
in a manner inconsistent with any of the procedures outlined in
this document. The user is responsible for determining whether this
product is appropriate for the intended application.
Juice Goose is not responsible for any indirect, secondary or ancil-
lary loss or damage, including personal injury, loss of or damage
to property or loss of income resulting from the operation or fail-
ure of this unit.

RX100-RM SPECIFICATIONS
DIMENSIONS (INCHES) 1.72 x 19.00 x 7.00
WEIGHT (LBS) 12
POWER INPUT 120 VAC, 60Hz
POWER OUTLETS 11 SINGLE NEMA 5-15R
CURRENT CAPACITY 15 AMPS
POWER CORD 12 FOOT, 14/3 SJT
TRANSIENT ENERGY ABSORBTION (JOULES) 1020
MAXIMUM APPLIED SURGE CURRENT (AMPS) 3000
MAXIMUM APPLIED SURGE PULSE VOLTAGE
(VOLTS)
6000
SURGE LET THROUGH RATE (VOLTS)
L-N10
N-G0.5
COMMON MODE (N-G) LINE NOISE REJECTION
(dB)
100 kHz 30
300 kHz 77
1 MHz 80
10MHz 80
30MHz 80
NORMAL MODE (L-N) LINE NOISE REJECTION
(dB)
100 kHz 21
300 kHz 56
1 MHz 60
10MHz 60
30MHz 60
CHASSIS DESIGN TOUR CLASS –UNIBODY
CHASSIS FINISH POWDER COAT ENAMEL

FRONT PANEL
Power On/Off Switch –This lighted rocker switch is located on the left
hand side of the chassis. The switch will light when the RX100-RM is on.
Light Connector –A BNC style connector is located on the left side of
the chassis and will accommodate a 12 volt AC gooseneck type work
light such as the style manufactured by CAE under the brand name
“Littlite”. (The light is not included with the RX100-RM.)
Light Control Switch –When this switch is in the “Up” position it will
activate power to the light connector.
Indicator Lights
TBF Protection –This green light indicates the RX100-RM protec-
tion circuit is functioning and the main AC power source is correct.
Wiring Fault –In the event of continuous high voltage or incor-
rect wiring of the line, neutral or ground leads supplying the RX100-RM,
the unit will disconnect equipment plugged into it. The green light will be
OFF and the red Wiring Fault indicator will light.
REAR PANEL
AC Outlets –These eleven outlets (NEMA 5-15R) are rated for current
loads up to 15 amps at 120 volts.
Breaker –A resettable, thermal circuit breaker protects the unit from
current overloads. If the breaker trips check for a malfunction in equip-
ment plugged into the RX100-RM. Also check to be certain the total cur-
rent requirement of the equipment plugged into the RX100-RM does not
exceed 15 amps.
The circuit breaker may be reset. Wait 30 seconds after the breaker
trips, turn off the main unit power switch and push the center button on
the breaker back into its original position. Then turn on the main power
switch.
INTERNAL PROTECTION COMPONENTS
The RX100-RM is one of the RX Series products which feature PoweRX
AC power protection. PoweRX protection uses a new, patented Trans-
former Based Filter TM technology to clean up both Normal Mode and
Common Mode noise without contaminating the ground. Normal Mode
noise occurs between the line and neutral leads of an electric power cir-
cuit. Common Mode noise occurs between either the line or neutral and
the safety ground lead.
UL 1449 limits the amount of current that can pass between line and
safety ground to 0.5 milli amperes. This is called " leakage current". The

Transformer Based Filter process control board, by using a differen-
tial transformer and capacitors, acts as a low pass, "line condition-
ing" filter which performs in the same way as a series mode induc-
tor. These components, along with a capacitor between neutral and
ground comprise the foundation of the Transformer Based Filter de-
sign which conditions incoming AC power, removing normal and com-
mon mode noise without adversely affecting the ground line.
TROUBLESHOOTING
The RX100-RM is ruggedly designed and constructed from high qual-
ity components to give years of dependable power for your equip-
ment. It requires neither maintenance nor adjustment. It is unlikely to
malfunction. However, there is one potential event to note:
The RX100-RM will not come on or turns itself off.
a. Check the status of the power supplied to the unit. If line
voltage exceeds 165 volts for 3 seconds protection circuitry will dis-
connect power to the AC power outputs. This will also occur if the
line and neutral leads are reversed. Use a voltage meter and/or po-
larity tester to examine the status of incoming power.
b. Check that the circuit breaker is not tripped and that the
current load on the unit does not exceed its rated 15 amp capacity. If
the breaker is tripped, remove sufficient current load to reduce the
total to no more than 15 amps, wait approximately 30 seconds after
the tripping, turn off the main power switch and push in the circuit
breaker button.
If an observed problem can not be remedied, particularly if the prob-
lem seems severe or dangerous, discontinue use of the RX100-RM
and contact Juice Goose directly.
REPAIR
Should your Rackpower need service contact Juice Goose for assis-
tance and authorization to return the unit. PLEASE NOTE: a return
authorization number is required in order for the service personnel
to correctly and promptly identify, repair and return your unit. You
may obtain a Return Authorization Number by calling: 713-772-1404

OTHER HIGH QUALITY PRODUCTS FROM
JG SERIES –Rack mountable power distribution in a 19” con-
figuration. Five models to choose from. Feature options include
rack lighting and voltage meter. The JG11-20A has a 20 amp ca-
pacity, 2 unswitched outlets and a 15 foot power cord. All units
contain a basic level of power conditioning.
PD SERIES –Custom configured power strips with up to 12 cir-
cuits per unit. The PD1A, PD1B and PD3 offer various options re-
garding size, number and arrangement of circuits, length and loca-
tion of wire harness and mounting configuration. Select exact con-
figuration with a features menu.
CQ SERIES –Power sequencing and remote control products.
No master controller is required. Very flexible, economical and easy
to install. Models include rack mount, four circuit and 30 amp de-
signs. Optional remote controls include key or rotary switch and
secure 12 position keypad.
UPS MODELS –When protection against power outage is
needed, Juice Goose is a source for 16 models of UPS products,
rack or tower mount, line interactive or on line. Call or email for
any specification or application assistance.
Table of contents
Other JuiceGoose Surge Protector manuals
Popular Surge Protector manuals by other brands

Leviton
Leviton 51005-WM installation guide

QVS
QVS PP114M Specification sheet

Total Protection Solutions
Total Protection Solutions ComTrack TK-CT2-DB9 Installation, operation and maintenance manual

Superior Electric
Superior Electric STABILINE DIN3-165 Series owner's manual

Panamax
Panamax PM8-GAV Specifications

Monacor
Monacor AHVB-240BNC instructions

Citel
Citel MJ8-POE-A installation instructions

ELAC
ELAC ProteK PR81-B Setup guide

Emerson
Emerson AccuGuide ACGY1110808 Specifications

Radio Shack
Radio Shack 8-Outlet Computer Network Equipment Surge... owner's manual

Crestron
Crestron CSP-LSP Operations & installation guide

Emerson
Emerson SolaHD SPD50K Series manual