Juro-Pro Eco II 16L User manual

Dehumidifier Instruction Manual
Please keep this instruction manual for future potential usage.

Contents
Please take some time to read this instruction manual and keep it for
potential usage.
Page
Warnings----------------------------------------------------1
Working principle------------------------------------------2
Working environment--------------------------------------3
Important Safety Measures--------------------------------4
Body of machine--------------------------------------------5
Operation Method------------------------------------------6-7
Drainage-----------------------------------------------------8
Maintenance-------------------------------------------------9
Storage-------------------------------------------------------10
Problem shooting------------------------------------------11-12
Safety Instructions-----------------------------------------13-16
Appendix----------------------------------------------------17-23

1
Warnings
This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or
lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by
children without supervision.
If the supply cord is damaged, it must be replaced by the manufacturer,
its service agent or similarly qualified persons in order to avoid a
hazard.
Meaning of crossed –out wheeled dustbin:
Do not dispose of electrical appliances as unsorted municipal waste,
use separate collection facilities.
Contact you local government for information regarding the
collection systems available.
If electrical appliances are disposed of in landfills or dumps,
hazardous substances can leak into the groundwater and get into the
food chain, damaging your health and well-being.
When replacing old appliances with new ones, the retailer is legally
obligated to take back your old appliance for disposals at least free of
charge.

2
Working Principle
This product is multifunctional dehumidifier, which can be set humidity
level according to different requirement. Through the machine settings, the
damp air flows through the body of the evaporator and radiator, and the
relative humidity of the room could be controlled: the excessive moisture
air flow through the evaporator, the air will condenses into water and then
exhaust to the water tank, after that the dry air flow through the radiator to
warm up then back to the room. So it’s a cycle, the machine reduce the
room humidity

3
Working environment
This is a multi-functional dehumidifier, and you can set the room humidity
according to requirement. It could create a healthy and comfortable
environment. The machine usually used in basement, wine cellar, storage,
closet. Also could be used in kitchen, library, showroom, computer room
archives, living room and bedroom.

4
Important Safety Measures
1. Keep the machine upright on the floor.
2. After be transported or tilted (caused by cleaning), the machine need to be
stopped for an hour and then plugged into power.
3. Make sure there’s 25CM distance around the machine.
4. Keep the outside object away from air inlet and outlet.
5. Don’t pour or splash water onto the machine.
6. The power supply must be accorded with the description in rating label.
7. Don’t plug/unplug the machine to open/close it and use the control panel.
8. Before moving the machine, you need to turn off it, unplug and ensure
the water tank is empty.
9. If the filter is dirty, it is better to clean it. When the filter is clean, the
machine works better.
10. Don’t use bad quality or flammable cleaner to clean the machine.
11. When there’s something wrong with the machine, turn off the machine,
unplug it.
12. When the wire is broken, you need to find a recognized reprehensive
office or qualified person to replace it in order to prevent the danger.

5
Body of Machine
1.Control panel
2.Air Inlet
3.Filter
4.Water Tank
5.Castor
6.Handle of water tank
7.Handle of machine
8.Air Outlet
9.
Continuous Drainage Outlet

6
Operation Method
Operation Panel Icon
Operation Instruction
ON/OFF
1. Connection of power (referring to the nameplate sticker of the power
requirements), press “ON/OFF” button to turn on the machine, then
power indicator lights. Display system shows fault setting models and
corresponding indicators light.
2. When machine is on work, press “ON/OFF” button to stop it, then all
indicators are off. (Note: in case long idle, please pull power plug off).
Timing function
1. When on work, pressing “TIMER” button to show current timing,
repeat pressing it to set auto shutting down at the range of 0-24 hours
(0 excluded). Starting timing, timing indicator lights. And when setting
time out, machine will be shut down automatically.
2. When off work, pressing “TIMER” button to show current timing,
repeat pressing it to set auto shutting down at the range of 0-24 hours
(0 excluded). Starting timing, timing indicator lights. When setting
time out, machine will be turned on automatically.
◆ Humidity setting
Acquiescent setting humidity of machine is RH50%, pressing “HUM”
button, displaying the current setting of humidity, pressing “HUM”
button again to set humidity at the range of RH40%~80%(5% for one
level),CO is continuous, These settings can be recycled.

7
Temperature display
Pressing“SPEED”button and mode button synchronously, Monitor
displays ambient temperature. Seconds later, it will show ambient
humidity again.
Choice of airflow speed
Acquiescent setting when starting is low airflow speed. Pressing
“SPEED” button to choose high or low airflow speed. Indicator lights.
Frost removal function
Machine has frost removal function. When defrosting, the dot on the
bottom-right of the humidity display will lighting all the time and the
compressor stops while the fan stills works.
Detection of full water
When tank is full, alarm buzzing, corresponding indicator lights and
machine stops working.
Anion function
The effect of anion is it can purify the air. Long pressing the mode
button can open or close the anion.
Switching to air purification mode
Press the mode button and then you can change the dehumidifier from
dehumidification to air purification or change from air purification to
dehumidification. When in air purification mode, the indicator
light lights and the compressor stops working

8
Drainage
When water in tank is full, machine will alarm and stop working
automatically, then indicator light turns red, reminding user pour out
Water in the tank:
1.Take bar of tank, pull out gently.
2. After pouring out water, bring tank back to original position. Then
machine works again. Indicator light is still lit and machine does not
works if tank is not placed in correct position.
7
Continuous Drainage
When machine should be worked for long time, please refer as
follows:
1.
Remove the rubber cap A on the continuous
drainage outlet and take off the rubber cap
B.Plug the long hose into the continuous
drainage outlet. Keep the hose downward to
ensure proper drainage. (Fig.1)
2.
Take out tank, insert drainage plug taken off
in the Step 1 to hole B (Fig.2)
3.
In order to make sure smooth drainage of water, drainage hose should
be connected in correct.
4.
Put tank back. (Fig.3)
5.
Take care of freeze-up
of hose when cold.

9
Maintenance
Pull off power plug from socket before maintaining or washing.
◆Cleaning
1. Clean machine by soft cloth
2. Do not clean machine by volatile chemicals, gasoline, detergent
chemical processed cloth or other cleaning solution, which may be harmful
to the machine.
◆Cleaning Air Filter
This machine is equipped with one filter at least (Note: activated carbon
filter is optional accessories):
1. Filter blocking dust
◆Filter
1. Outer dust filter cleaning: removing the grid, then take off filter
from the back of machine(fig.4)
2.
Let dust off by a vacuum cleaner o
r brush it
gently.
If filter is too dusty, clean it with warm water
(fig.5)
Make sure filter is dry when put back to fixed
position.
Do not expose filter to sun.
3.
Inner carbon filter cleaning: take off carbon filter from inlet grid,
Let dust off
by a vacuum cleaner o
r brush it gently. Do not use wash it by water and not let it
be exposed to sun. Change carbon filter semi-annually.
Fig.5

10
Storage
When machine does not run for long time, please do as
follows:
1. Turn off machine, cut off power and sort out power cord.
2. Pour out tank water and wipe it.
3. Clean the filter.
4. Cover up machine and place it in one position unexposed to sun

11
Problem Shooting
Before calling for service, please make following check:
Problems Possible causes
Machine does not work Whether plug is in the power?
Whether electrical wires indoor in
the power?
Whether full water indicator is lit?
(If lit, water tank is possibly full
of water or not placed in correct
position)
Whether temperature indoor is
lower than 5℃?
Machine does not remove
moisture
Whether the filter is dusty or is
contaminated?
Whether inlet or outlet is blocked?
Whether humidity indoor is too
less?
Dehumidification effect is not
obvious
Whether you are opening too many
windows or doors?
Whether there are machines indoor
making much humidity?
Leaves seems unworking
Whether filter is clogged?
Much noise Whether the vibration is caused by
uneven placement of the machine?
Whether the machine is not even on
uneven floor?
Users can not repair or disassemble the product. Coming across
breakdown, please call professional electric appliance Services and
Repairers for help.

12
Problem Shooting
The following symptoms are not failure:
Symptoms Causes
Noise gets bigger when machine
starts
When compressor starts, noise of
compressing gets bigger.
Machine will pump out musty
taste in first use
Temperature of heat exchanger
rises suddenly, leading to
temporary strange smell or musty
taste.
Machine echoes If machine used in a small room,
or a wooden floor room, may
echo.
At the start of operation mode or
switched to this mode, machine
will make abnormal noise
Refrigerant before restoring
stability flow may noise.
Water spots in water tank These are left traces of water
evaporation after factory
dehumidification test.

13
Safety Instructions
Warning
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
The appliance shall be stored in a room without continuously operating ignition
sources (for example: open flames, an operating gas appliance or an operating
electric heater.)
Do not pierce or burn.
Be aware that refrigerants may not contain an odor.
Appliance shall be installed, operated and stored in a room with a floor area
larger than 12.5 m
2
.
Keep any required ventilation openings clear of obstruction.
Servicing shall be performed only as recommended by the manufacturer.
The appliance shall be stored in a well-ventilated area where the room size
corresponds to the room area as specified for operation.
Any person who is involved with working on or breaking into a refrigerant
circuit should hold a current valid certificate from an industry-accredited
assessment authority, which authorizes their competence to handle refrigerants
safely in accordance with an industry, recognized assessment specification.
Servicing shall only be performed as recommended by the equipment
manufacturer. Maintenance and repair requiring the assistance of other skilled
personnel shall be carried out under the supervision of the person competent in
the use of flammable refrigerants.
All working procedure that affects safety means shall only be carried by
competent persons.
Be careful not to bump when moving to avoid leakage in the refrigeration line.
Flammable material. Refer operators Read technical
Read operators
This appliance contains R290/ manual manual
Propane a flammable refrigerant

14
The maximum dosage of refrigerant is 60g
Notes:
The dehumidifier is only suitable for indoor use, and is not suitable for other
applications.
Place the machine in a flat and dry place and keep a distance of above 50cm
between the machine and the surrounding objects or walls.
After the dehumidifier is installed, ensure that the power plug is intact and firmly
plugged into the power outlet, and place the power cord orderly to prevent
someone from being tripped or pulling out the plug.
Do not put any object into the air inlet and outlet of the dehumidifier. Keep the
air inlet and outlet free from obstructions.
When drainage pipes are installed, ensure that the drainage pipes are properly
connected, and are not distorted or bended.
When moving the machine, make sure that it is in an upright position.
The machine should stay away from gasoline, flammable gas, stoves and other
heat sources.
Don't disassemble, overhaul and modify the machine arbitrarily, otherwise it will
cause a machine malfunction or even bring harm to persons and properties. To
avoid danger, if a machine failure occurs, ask the manufacturer or professionals
to repair it.
Do not pull the plug to turn off the machine.
Do not place cups or other objects on the body to prevent water or other liquids
from spilling into the dehumidifier.
Do not use insecticide sprays or other flammable substances near the
dehumidifier.
Do not wipe or wash the dehumidifier with chemical solvents such as gasoline
and alcohol. When you need to clean the air conditioning, you must disconnect
the power supply, and clean it with a half-wet soft cloth. If the machine is really
dirty, scrub with a mild detergent.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction
Concerning use of the appliance by a person responsible for their safety. (Except

15
for the humidifier with CE-MARKING)
Children should be supervised to ensure that they do not play with the appliance.
(Except for the humidifier with CE-MARKING)
The appliance can be used by children aged from 8 years and above and persons
with reduced physical, sensory or mental capabilities if they have been given
supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance.
Cleaning and maintenance shall not be made by children without supervision
(Only for the humidifier with CE-MARKING)
If the supply cord is damaged, it must be replaced by the manufacturer, its
service agent or similarly qualified persons in order to avoid a hazard.
Transportation, marking and storage for units
1. Transport of equipment containing flammable refrigerants
Compliance with the transport regulations
2. Marking of equipment using signs
Compliance with local regulations
3. Disposal of equipment using flammable refrigerants
Compliance with national regulations
4. Storage of equipment/appliances
The storage of equipment should be in accordance with the manufacturer’s
instructions.
5. Storage of packed (unsold) equipment
Storage package protection should be constructed such that mechanical damage to
the equipment inside the package will not cause a leak of the refrigerant charge.
The maximum number of pieces of equipment permitted to be stored together will
be determined by local regulations.
The appliance shall be stored so as to prevent mechanical damage from occurring
Remark:
The best operating ambient temperature is 5-35 ° C.

16
The fuse mode is 4T or 4F or 334 or L3CT, the specification is
AC250V, 3.15A
.
Appliance is filled with flammable gas R290, and the maximum charge of
refrigerant is 60g. GWP value of R290 refrigerant is 3.
Any repairs you need, contact the nearest authorized Service Centre and strictly
follow manufacturer’s instruction only

17
APPENDIX
1. Information on servicing
1) Checks to the area
Prior to beginning work on systems containing flammable refrigerants, safety checks
are necessary to ensure that the risk of ignition is minimized. For repair to the
refrigerating system, the following precautions shall be complied with prior to
conducting work on the system.
2) Work procedure
Work shall be undertaken under a controlled procedure so as to minimize the risk of a
flammable gas or vapor being present while the work is being performed.
3) General work area
All maintenance staff and others working in the local area shall be instructed on the
nature of work being carried out. Work in confined spaces shall be avoided. The area
around the workspace shall be sectioned off. Ensure that the conditions within the
area have been made safe by control of flammable material.
4) Checking for presence of refrigerant
The area shall be checked with an appropriate refrigerant detector prior to and during
work, to ensure the technician is aware of potentially flammable atmospheres. Ensure
that the leak detection equipment being used is suitable for use with flammable
refrigerants, i.e. non-sparking, adequately sealed or intrinsically safe.
5) Presence of fire extinguisher
If any hot work is to be conducted on the refrigeration equipment or any associated
parts, appropriate fire extinguishing equipment shall be available to hand. Have a dry
powder or CO
2
fire extinguisher adjacent to the charging area.
6) No ignition sources
No person carrying out work in relation to a refrigeration system which involves
exposing any pipe work that contains or has contained flammable refrigerant shall use
any sources of ignition in such a manner that it may lead to the risk of fire or
explosion. All possible ignition sources, including cigarette smoking, should be kept
sufficiently far away from the site of installation, repairing, removing and disposal,
during which flammable refrigerant can possibly be released to the surrounding space.
Prior to work taking place, the area around the equipment is to be surveyed to make

18
sure that there are no flammable hazards or ignition risks. “No Smoking” signs shall
be displayed.
7) Ventilated area
Ensure that the area is in the open or that it is adequately ventilated before breaking
into the system or conducting any hot work. A degree of ventilation shall continue
during the period that the work is carried out. The ventilation should safely disperse
any released refrigerant and preferably expel it externally into the atmosphere.
8) Checks to the refrigeration equipment
Where electrical components are being changed, they shall be fit for the purpose and
to the correct specification. At all times the manufacturer’s maintenance and service
guidelines shall be followed. If in doubt consult the manufacturer’s technical
department for assistance.
The following checks shall be applied to installations using flammable refrigerants:
a) The charge size is in accordance with the room size within which the refrigerant
containing parts are installed.
b) The ventilation machinery and outlets are operating adequately and are not
obstructed.
c) If an indirect refrigerating circuit is being used, the secondary circuit shall be
checked for the presence of refrigerant.
d) Marking to the equipment continues to be visible and legible. Markings and
signs that are illegible shall be corrected.
e) Refrigeration pipe or components are installed in a position where they are
unlikely to be exposed to any substance which may corrode refrigerant containing
components, unless the components are constructed of materials which are inherently
resistant to being corroded or are suitably protected against being so corroded.
9) Checks to electrical devices
Repair and maintenance to electrical components shall include initial safety checks
and component inspection procedures. If a fault exists that could compromise safety,
then no electrical supply shall be connected to the circuit until it is satisfactorily dealt
with. If the fault cannot be corrected immediately but it is necessary to continue
operation, an adequate temporary solution shall be used. This shall be reported to the
owner of the equipment so all parties are advised.
This manual suits for next models
3
Table of contents
Other Juro-Pro Dehumidifier manuals