König KN-BLDPRESS30B User manual

Description (g. A) English
The blood pressure monitor is a device used to measure a person’s blood pressure. The device
measures the systolic blood pressure, the diastolic blood pressure and the pulse rate of an adult
individual.
KN-BLDPRESS30B / LS810-B
Blood pressure monitor
2
8
9
10
12
11
5
4
3
1
4
17
16
15
14
13
6
7
MEM
SET
A
B
C
1. Monitor
2. Cu
3. USB port
If the low-battery indicator comes on, charge the device:
• Connect the USB cable to the USB port and the power adapter.
• Insert the mains plug of the power adapter into the wall socket.
4. Display
5. Start/stop button
• Press the button to switch on or o the device.
• When the device is switched o, press and hold the button to pair the
blood pressure monitor with your mobile device.
6. Memory button
Up button
• Press the button to enter or exit memory mode.
• Clock mode: Press the button to set the date and the time.
7. Set button
Down button
• Press the button to enter or exit setting mode.
• Clock mode: Press the button to conrm the date and the time.
8. Systolic blood
pressure indicator • The indicator shows the systolic blood pressure.
9. Diastolic blood
pressure indicator • The indicator shows the diastolic blood pressure.
10. Pulse rate indicator • The indicator shows the pulse rate.
11. Date indicator • The indicator shows the date.
12. Time indicator • The indicator shows the time.
13. Memory indicator • The indicator comes on when the device is in memory mode.
14. Error indicator • The indicator comes on when there is an error.
15. Low-battery
indicator • The indicator comes on when the batteries are low.
16. Bluetooth indicator • The indicator shows the Bluetooth connection status.
17. Irregular-heartbeat
indicator
• The indicator comes on when the device detects an irregular
heartbeat.
Denitions
• Systolic blood pressure: maximum arterial pressure during contraction of the left ventricle
of the heart.
• Diastolic blood pressure: minimum arterial pressure during relaxation and dilatation of the
ventricles of the heart when the ventricles ll with blood.
• Pulse rate: number of pulsations in the radial artery per minute.
• Hypotension: low blood pressure.
• Prehypertension: precursor to chronic high blood pressure.
• Hypertension: high blood pressure.
• Hypertensive emergency: high blood pressure with acute impairment of one or more
organ systems which can result in irreversible organ damage.
Blood pressure classication
Blood pressure classication Systolic blood pressure (mmHg) Diastolic blood pressure (mmHg)
Hypotension < 120 < 80
Normal 120 - 129 80 - 84
Prehypertension 130 - 139 85 - 89
Hypertension (stage 1) 140 - 159 90 - 99
Hypertension (stage 2) 160 - 179 100 - 109
Hypertensive emergency ≥ 180 ≥ 110
Safety
• Read the manual carefully before use. Keep the manual for future reference.
• Only use the device for its intended purposes. Do not use the device for other purposes
than described in the manual.
• Do not use the device if any part is damaged or defective. If the device is damaged or
defective, replace the device immediately.
• The device is designed for adults. Do not use the device on infants or young children.
Before use on older children, consult your physician.
• Do not use the device if you suer from arrhythmia (irregular heartbeats).
• If you are in doubt whether to use the device or not, consult your physician.
• The measurements are only an indication of your blood pressure level. If the device
measures a high or low blood pressure level, consult your physician.
• Only use the supplied cu.
• Measure your blood pressure at approximately the same time each day.
• Before measurement, stay calm and rest for 5 minutes. Relax at least 1 minute between
multiple measurements to allow the blood circulation to recover. Too frequent
measurements can cause injury due to blood ow interference.
• Do not speak or move during measurement.
• Do not expose the device to water or moisture.
• Do not use the device in areas where interference from other devices can cause inaccurate
measurements.
• Do not use the device in a moving vehicle.
Installation
• Download and install the“Transhealth”app from Apple App Store or Google Play Store on
your mobile device.
• Open the“Transhealth” app.
• Activate Bluetooth on your mobile device.
• Go to the settings menu
• Select “Add device”in the settings menu.
• Press and hold the start/stop button for 5 seconds. The blood pressure monitor will be
paired with your mobile device.
Use
Setting the date and the time
1. When the device is switched o, press and hold the set button for three seconds. The
device is in clock mode.
2. Press the memory button to set the hour. Press the set button to conrm.
3. Press the memory button to set the minutes. Press the set button to conrm.
4. Press the memory button to set the month. Press the set button to conrm.
5. Press the memory button to set the day. Press the set button to conrm.
6. Press the memory button to set the year. Press the set button to conrm.
www.ekt2.com
Electronics Katrangi Trading
Applying the cu (g. B)
• Refer to the illustration to apply the cu.
Body posture during measurement (g. C)
• Refer to the illustration for the correct body posture during measurement.

Measuring the blood pressure
1. To switch on the device, press the start/stop button. The display shows all display items.
2. The monitor starts to seek zero pressure.
3. The monitor inates the cu until there is sucient cu pressure.
4. The monitor slowly releases air from the cu and carries out the measurement. The display
shows the systolic blood pressure, the diastolic blood pressure and the pulse rate. The
results are stored in the memory automatically.
5. To switch o the device, press the start/stop button again.
Reading measurements from the memory
1. Press the memory button. The display shows the amount of results in the memory,
followed by the most recent result.
2. Repeatedly press the up button or the down button to navigate through the results.
Deleting measurements from the memory
• When the display shows a result, press and hold the memory button for 3 seconds. All
results in the memory are deleted.
Error codes
Error code Cause Solution
Bluetooth indicator
+ Error indicator Data communication error.
Make sure that Bluetooth is activated on
your mobile device.
Make sure that your mobile device is
within the Bluetooth range.
E2 The cu is too tight during
ination.
Apply the cu correctly and measure
again.
E3 The cu pressure is too high. Relax for a moment and measure again
after 5 minutes.
E9 The device has not been activated. Reactivate the device.
E10 / E11 The device has detected motion
during measurement.
Relax for a moment and measure again
after 5 minutes.
E20 The device does not detect the
pulse signal.
Loosen the clothing on the arm and
measure again.
E21 Measurement error. Relax for a moment and measure again
after 5 minutes.
EExx Calibration error.
Measure again after 5 minutes. If the
display still shows the error code, contact
the local distributor or the factory.
Cleaning and maintenance
Warning!
• Do not use cleaning solvents or abrasives.
• Do not clean the inside of the device.
• Do not attempt to repair the device. If the device does not operate correctly, replace it
with a new device.
• Clean the outside of the device using a soft, damp cloth.
• If you use the device frequently, disinfect the cu at least twice a week. Apply ethyl
alcohol (75-90%) to a soft cloth, wipe the inner side of the cu with the cloth and allow
the cu to dry naturally.
• Clean the outside of the device using a soft, damp cloth.
• If you use the device frequently, disinfect the cu at least twice a week. Apply ethyl
alcohol (75-90%) to a soft cloth, wipe the inner side of the cu with the cloth and allow
the cu to dry naturally.
• Clean the outside of the device using a soft, damp cloth.
• If you use the device frequently, disinfect the cu at least twice a week. Apply ethyl
alcohol (75-90%) to a soft cloth, wipe the inner side of the cu with the cloth and allow
the cu to dry naturally.