Installation, Programming and Operation Manual
02
SPECIFICATIONS
This unit has been designed to provide
reasonable protection against harmful
interference in a residential install.
This equipment uses, generates and can
radiate radio frequency energy and, if not
installed and used in accordance with the
instructions, may cause harmful interference
to radio communications. There is no
guarantee that interference will not occur
in any particular install.
If the equipment does cause harmful
interference to radio or television
reception, which can be determined by
turning the equipment off and back on again,
the user is encouraged to try to correct the
interference by:
(1) reorient or relocate the receiving antenna;
(2) increase the separation between the
equipment and receiver;
(3) connect the equipment into an outlet
on a different circuit from the receiver;
(4) consult the dealer or an experienced
radio / TV technician for help.
Changes or modifications to this equipment
could void the warranty.
DIMENSIONS
• Width: 15.45" / Height 11.91" / Depth 6.43"
• Width 39.24 cm / Height 30.25 cm / Depth 16.33 cm
OPERATING SPECIFICATIONS
• Station Run Times: 1 second to 9:59:59
Programs A, B, C, D, E, & F
• Start Times: 6 per program
• Watering Schedule: 7 Day Calendar
(any day of the week) odd or even days,
interval watering up to 31 days.
• Operating Temperature:
0° - 140°F (18° - 60° C)
• Zone Capacity: 99
Zone groups limited to 6 zones and
1 MV/PS per primary line (A and B total)
for a total of 12 zones
• Pump Start requirements:
Pump Start relays hard-wired to the provided
locations on the SiteMaster controller will require
the use of a K-Rain 1520 or 1510 Mini Coil relay.
Remote Pump Start relays running with a decoder on
the 2-wire path require a K-Rain 3410 Optical Relay at
each location. Coil voltage rating of 120V or 240V
only. See optical relay manual for installation guide.
DEFAULT SETTINGS
• The SiteMaster controller has non-volatile
memory that retains all programming data
even during power outages and without the
need for any battery back-up. Batteries are
used for time and calendar accuracy and 9V
is used for remote programming when the
main panel is removed from the cabinet.
ELECTRICAL SPECIFICATIONS
• 2-wire transformer
Input: 120/240 VAC 50/60 Hz
Max Output: 27 VAC 100VA 3.7 AMP
• Midbox Transformer
Input: 120/240 VAC 50/60 Hz
Max Output: 24 VAC 40VA 1.71 AMP
• Battery:
- 2032 Coin Cell (included)
- 9V alkaline battery (optional)
(not included)
• For PERMANENTLY CONNECTED EQUIPMENT,
a readily accessible disconnect device shall
be incorporated external to the equipment.
FIRMWARE VERSION ID
Displays the version of firmware installed.
SET
Program
Start Times
AUTOOFF
RUN
Single Zone/
System Test
Special
Features
Program
Display
Connectivity
Decoder
Status
Program
Decoder
Controller
Cong.
Sensor
Cong.
SET
Zone
Run Times
SET
Watering
Days
PROGRAMS
ERROR
DISABLED ON
BACK DECREASE INCREASE NEXTSTART
RAIN
SENSOR
OK
DE F
AB C
SET DATE
MIDPCB VER J813 LINE1 VER00 LINE2 VER00
01SET DATE NOV 19
BACK
DECLARATION OF CONFORMITY