IW/
wowbiii^
imuuitt
^uai
U
IIJ
Set
the
needle guard
horizontally
so
that
it
barely
contacts
the
needle
when
at
its
extreme forward
position.
It
should be
set
vertically
as low as
possible, yet have
its
top of guarding
surface
is
I.Om/m
higher
than
the
point
of
the
needle
on
its
way
of
leftward
motion.
To
adjust,
loosen
screw A
to
attain
proper
position.
Retlghten
screw A
securely.
14)
Adjustment
of locper thread take-up (Fig 12,13)
a) Set the looper thread retainer E so
that
the distance
from
its
underside
to the surface of
needle
plate is
6-7m/m.
To
adjust, loosen
screw
G
move
thread retainer
Evertically to attain
its
height. Retighten
screw
G.
b) Setting looper thread take-up eyelet
proper
location
of
thread
take-up
eyelet
D
should
be
vertically
in
line
with
the
center
of
main
shaft.
Loosen
set
screw A
move
eyelet
to
attain
its
position.
Retighten
set
screw
A
securely.
6~7m
Adjustment of take-up
cam
(Fig 13,12)
The
looper thread should begin to be released
when
the
blade of looper and the point of the
needle are at horizontally the
same
height, in
its
motion toward
right.
To
adjust,
loosen
screw
Cslightly but rigid
enough
to
retain
its
position,
move
take-up
cam B
to
attain
proper
position.
Retighten
screw C
securely.
-i
-
CB)
Fig.
12
Fig.
13