Kasco marine 2400EAF User manual

Owners Manual
50Hz Aerator & Circulators
Contents
Important Safety Instructions . . . . . .pg2
Unit Specs . . . . . .pg2
Quick Disconnect Installation . . . . . .pg2
Wire Sizing & Gland Sizing . . . . . .pg4
2400EAF, 3400EAF, 4400EAF Aerator Parts . . . . . .pg4
2400EAF, 3400EAF, 4400EAF Assembly . . . . . .pg5
8400EAF & 3.1EAF Parts . . . . . .pg6
8400EAF & 3.1EAF Assembly . . . . . .pg7
Installation Instructions . . . . . .pg8
Circulator Parts (ECF Models) . . . . . .pg8
Circulator (ECF Model) Assembly . . . . . .pg9
Maintenance Recommendations . . . . . .pg11
Troubleshooting Tips . . . . . .pg12
Rev. 06/11/09
Kasco Marine, Inc.
800 Deere Rd.
Prescott, WI 54021
U.S.A.
PH 00+1+715+262+4488
FAX 00+1+715+262+4487
www.kascomarine.com

2
CAUTION
NOTICE (NOTE)
These international safety symbols are used through-
out this manual to inform the owner of important
safety information and notices for safe and effective
use of the equipment.
Important Safety Instructions
CAUTION
Under NO circumstances should anyone enter• the water with the electrical equipment con-
nected and/or in operation. It is NEVER rec-
ommended to enter the water with the equip-
ment in operation.
Caution should be used when dealing with any• electrical equipment with moving parts.
NEVER run the unit out of water. It will dam-• age the seals and create a dangerous situation
for the operator.
Extreme caution should be used around water,• especially cold water, such as in Spring, Fall,
and Winter, which poses a hazard in and of
itself.
NEVER lift or drag the unit by the power or• light cord. If you need to pull the unit to the
side of the pond, use the anchoring ropes.
Do not use waders in deep ponds/lakes or• ponds/lakes with drop-offs, drastic slopes, or
soft bottom material.
Do not use boats that tip easily for fountain• installation, such as a canoe, and follow all
boating safety rules and regulations, including
wearing a PFD. (Personal Flotation Device)
The unit is supplied with an internal ground-• ing conductor. To reduce the risk of electrical
shock, be certain that the unit is plugged/con-
nected to an approved RCD (GFCI) protected
circuit.
Means for disconnection must be incorporated• in the fixed wiring in accordance with local and
national wiring rules.
Consult a qualified electrician for electrical• installation.
Unit Specs
Model Voltage Operating
amps lock rotor
amps
2400EAF 208-240 2.2@240V 6@240V
3400EAF 208-240 3.4@240V 9@240V
4400EAF 208-240 3.7@240V 20@240V
8400EAF 208-240 8.0@240V 40@240V
3.1EAF 208-240 11.9@240V 60@240V
2400ECF 208-240 2.2@240V 6@240V
3400ECF 208-240 3.4@240V 9@240V
4400ECF 208-240 3.7@240V 20@240V
8400ECF 208-240 8.0@240V 40@240V
Quick Disconnect Installation
Important – Read Carefully Before Installation
Before using the connector, it is important that these
instructions are carefully read and understood to
ensure the connector system is completely water tight
and electrically safe.
IF IN DOUBT CONSULTA QUALIFIED ELECTRI-
CIAN.
The socket (female) insert of the connector must be
the live part of the connector from the supply. The pin
(male) insert of the connector must lead to the load or
electrical device. On 50Hz units, the pin (male) insert
of the connector is installed at the factory. To ensure
efficient sealing, use only smooth circular cable.
Pin Insert (Installed on Stub Cord)
Pin Insert Main Body Gland Gland Nut
Socket Insert (User Installed)
Socket insert Main Body Gland Gland Nut

3
Note:
White gland for 9-11mm O.D.
Yellow gland for 13-15mm O.D.
Assembly/Wiring Instructions
STEP ONE
Remove the socket insert from the housing of the con-
nector. There is a slot for a flat blade screwdriver in
the center of the insert.
Note: The inserts have a LEFT HAND
THREAD and should be turned clockwise to remove.
STEP TWO
Remove the gland nut and gland from the rear of the
housing and slide on to the cable. Make sure the gland
is orientated with the stepped edge facing the gland
nut (see picture). Stepped Edge
STEP THREE
Prepare the cable and strip wire ends as shown.
Wire Stripping
STEP FOUR
Insert the stripped wire ends into the terminals on the
back of the Pin/Socket insert and fully tighten the
wire retention screws. (Refer to figure for correct wire
orientation).
Figure 5:
Wire Connections
Brown wire to terminal L
Blue wire to terminal N
Green/Yellow wire to terminal E
After the wires have been connected securely, pull the
cable and insert back into the housing and tighten with
a screwdriver to ensure the insert is seated correctly.
Note: LEFT HAND THREAD, turn the insert
counter clockwise to tighten.
STEP FIVE
Prepare your supplied Resin Kit by removing the cap
from the resin tube and pushing the resin nozzle onto
the tube. Then twist the nozzle to lock in place.
Plunger Resin Tube Nozzle
Before applying to the quick disconnect, use the
plunger to evenly push out a small amount of resin to
get a proper mix of of the 2-part epoxy. Then apply
resin into the housing, enough to cover the wires and
contacts. The resin should be about 3mm onto the
cord jacket. Note: Adding too much resin may cause
excess to be forced into the female end of the pin
connector, preventing proper connection of the two
halves.
Cut-Away
disconnect shown
with clear resin.
Note amount that is
covering cord jacket.
STEP SIX
Slide the gland and gland nut along the cable into the
body and tighten the gland nut securely. No drying
time is needed for the epoxy before full assembly.

4
Kasco 50 Hz Equipment Wire Size Chart
Model Cord Length
10m 30m 60m 90m
2400EAF 1.5mm21.5mm22.5mm22.5mm2
2400ECF 1.5mm21.5mm22.5mm22.5mm2
3400EAF 1.5mm21.5mm22.5mm22.5mm2
3400ECF 1.5mm21.5mm22.5mm22.5mm2
4400EAF 1.5mm21.5mm22.5mm24mm2
4400ECF 1.5mm21.5mm22.5mm24mm2
8400EAF 1.5mm22.5mm24mm26mm2
8400ECF 1.5mm22.5mm24mm26mm2
3.1EAF 1.5mm22.5mm26mm26mm2
2400EAF, 3400EAF, 4400EAF Aerator
Parts
Aerator (Unit with cord or unit with Disconnect)1. (1)
Float (with two 50’mooring ropes attached) (1)2. 1/4-20 x 3 1/2” Phillips Pan Head Screw (4)3. 1/4” split washers (4)4. 1/4” (3/4” outer diameter) Flat Washer (4)5. Float Retaining Clips (4)6.
(Optional bottom screen)
3/8”-16 x 1-3/8” Hex Head Bolt (2)7. 3/8” Flat Washer (4)8. Bottom Screen cushions (3)9. Bottom Screen (1)10. Bottom Screen Clips (2)11. 3/8”-16 Nylon Lock Nut (2)12.
STEP SEVEN
Once the two subassemblies have been completed,
they can be joined together. Plug pin assembly into
the socket assembly and tighten the large blue nut
securely. The blue nut should be hand tightened only.
(See figure below).
Note: There is a small gap after tightening
For seasonal removal, your quick disconnect includes
an optional water tight cover. Simply separate the
quick disconnect and insert the sealing cover into the
large blue nut half and tighten firmly.
Strain Relief
The Strain Relief must be installed to protect the
Quick Disconnect from damage due to excessive
strain. The Strain Relief should be installed on the
user supplied cord length (not on the Kasco supplied
stub cord). It should be position about 15cm from the
Quick Disconnect. To install, insert the narrow end of
the elongated clamp with the chain connected into the
wide end of the short clamp. Use a rubber mallet to
tap the two pieces together securely. A Nylon Tie can
be used to keep it attached to the cord. The chain can
then be attached to the float.
Wire Sizing & Gland Sizing
The chart below shows the proper Gland to be used
with different cord sizes. The measurements are based
on the Outside Diameter (O.D.) of the cord. Smooth,
round cords should be used.
Kasco Quick Disconnect 50 Hz Size Chart:
Gland O.D. of Cord
Grey 7-9mm
White 9-11mm
Black 11-13mm
Yellow 13-15mm

5
logo
Rest the float on the cage top ring.
STEP TWO
Ensure correct alignment by twisting the float gently
around the motor housing until the power cord guide
lines up with the cord. See diagram of bottom side of
float. Bolt holes
power cord
guide
STEP THREE
Use one of the 1/4”-20 x 3-1/2” Phillips Pan Head
Screws (Part 3), one 1/4” split washer (Part 4), and a
1/4” Flat Washer (Part 5) to secure the float. Make
sure the split washer goes between the bolt head and
the flat washer. Insert screw with washer through bolt
hole in float.
Use one float retaining clip (Part 6) under the top ring
of the cage. There is a U-shaped indent in the clip that
will fit snug against the top ring of the cage. The 1/4”-
20 x 3-1/2” will then thread into the retaining clip.
float retain
float retain
ing clip
ing clip
1
2
3
4
5
7
8
6
9
10
11
12
2400EAF, 3400EAF, 4400EAF
Assembly
STEP ONE
Set motor housing upright (stainless steel can down)
on a flat surface. With motor housing upright, slide
Float (Part 2) over pump housing making sure the
surface with the Kasco logo is up.

6
Tighten until snug with a Phillips Head screw driver
and repeat for 3 remaining screws.
STEP FOUR
Turn secured assembly upside down so the top of the
float (logo side) is face down on the flat surface. Place
Bottom Screen (Part 10) onto the bottom side of the
float. Make sure the wide opening of the screen is
against the float and the 3 handles on the screen do not
interfere with the rope placements. Fit the 3 Bottom
Screen cushion (Part 9) underneath the screen and on
top of the 3 spacing bumps on the bottom of the float.
Bottom Screen cushion
STEP FIVE
Using a stainless steel Bottom Screen Clip (Part 11),
3/8”-16 x 1-3/8” Bolt (Part 7), two 3/8” Flat Washer
(Part 8), and 3/8”-16 Nylon Lock Nut (Part 12) to
secure the screen to the float. Align a clip so the two
prongs straddle a wire on the screen. Insert bolt with
washer so the top of the bolt is facing the top of float
(now in down position). Place the second washer and
the locking nut with nylon insert on the end of the bolt
and tighten using the 9/16” (14mm) Socket and Ratch-
et on the nut end and the 9/16” (14mm) Wrench on the
bolt end. Tighten until snug and repeat with remaining
clip.
STEP SIX
Turn the assembly upright again. At this time, if the
cord contains a metal strain relief, you can use the
chain connector and attach it in one of the opening at
the rope placement. The chain connector will easily fit
if installed from the bottom or top side of the opening.
It will not fit if installed from side of opening. Use the
Nylon Cable Tie (Part I) included to secure the power
cord to a molded hole in the float to prevent cord
damage if there is no strain relief on the cord. If a
Strain Relief is present on the cord, you may disregard
the Nylon Tie. On cords with a Quick Disconnect,
the disconnect should be tightened properly to avoid
leaking. If installing a new Quick Disconnect, refer to
Quick Disconnect Instructions. If ready to install in
the pond, go to Installation instructions.
8400EAF & 3.1EAF Parts
B2. Large Float Ring
See Diagram below.
1. Float Section (3)
2. Top Float Bracket (3)
3. Bottom Float Bracket w/Rope (3)
4. 9” x 3/8” Bolt (6)
5. 3/8” Lock Nut (6)
6. Unit Mounting Bracket
7. 1/4”x 3/4” Bolt
8. 1/4” Lock Washer
9. 1/4” Nut (3)
10. Bottom Screen (1 - optional)
11. Bottom Screen Clips (3 - optional)

7
STEP FOUR
Turn the assembly upside down and place the Bottom Float
Brackets (Part B3) over the bolts, the ends of which should
now be extending through the assembly. Loosely install
the six Lock Nuts (Part B5) on the ends of the bolts (do not
tighten yet). Connect the top and bottom brackets using
three 1/4” x 3/4” Bolts (Part B7) with the three 1/4” Lock
Washers (Part B8) and 1/4” Nuts (Part B12) and tighten us-
ing the 7/16” (11mm) wrench and socket.
STEP FIVE
Return the assembly to the upside down position and place
the motor assembly (Stainless Steel can side up, black
pump down) in the center of the float. Attach the motor to
the float using the Unit Mounting Brackets (Part B6). The
notch in the center of the Unit Mounting Brackets should
be positioned over the top ring of the cage and should be
attached to the float bracket using the two lowest holes of
the float bracket.
Tighten using the 1/4” x 3/4” Bolts with 1/4” Lock Washers
using the 7/16” socket and wrench. (See pictures) Note:
If you have trouble positioning the Unit Mounting Bracket
between the Cage and Fountain Housing, you can use a
screwdriver to gently pry open enough space.
STEP SEVEN
(Optional Bottom Screen: purchased separately)
Position the Bottom Screen (Part B10) over the float
so the motor housing (can) passes through the large
hole in the center of the screen. Remove the center
three Lock Nuts from the 9” Bolts and place the Bot-
tom Screen Clips (Part B11) over the bolts as shown.
The power cord can be slid under the bottom screen
where two float sections come together before the
Lock Nuts are replaced. Replace the three inside Lock
Nuts and tighten all 3/8” Lock Nuts using the 9/16”
(14mm) wrench and socket.
Note: Extra hardware may be included.
Tools & Supplies Needed:
A. Anchors or stakes for installing unit (2 or 3 de-
pending on unit)
B. 208-240V Electrical Supply near pond on a post
C. Two (or 3 depending on model) 30cm pieces of
2.54cm galvanized pipe for weighting ropes (optional)
D. 9/16”(14mm) & 7/16” (11mm) Nut Driver
E. 9/16” (14mm) & 7/16” (11mm) Socket
Adjustable crescent wrench
8400EAF & 3.1EAF Assembly
STEP ONE
Remove all contents from package and place on a
clean, flat surface. Inspect the shipment for any dam-
ages. Make sure you have all the parts needed.
STEP TWO
Arrange the three Float Sections (Part B1) upright
(plug on bottom) so the overlap of one section aligns
with the next section and loosely push the three sec-
tions together to form a continuous ring.
Float up Float down
(plug)
STEP THREE
Position one Top Float Bracket (Part B2) so that the bolt
holes in the bracket align with the bolt holes in the two
adjoined float sections and insert two 9” Black Coated
Bolts (Part B4) through the assembly. This may require
some minor repositioning of the float sections as you push
the bolt all the way through. Do not force the bolt through.
Repeat for the remaining two joints.

8
2.54cm galvanize pipe works well) at the mid-point of
the rope to take up any slack as the water level drops.
The weight should be light enough so the Unit can rise
as the water level rises. This can also help hide ropes
by sinking them further below the surface.
Normal Water level
Power Cord
Anchor Rope
Secondary Weight
Low Water Level
Kasco Power
Control Box
High Water Level
STEP THREE
At this time the Aerator is ready for operation. It can
be plugged into the power supply at the pond edge.
ENJOYYOUR NEW KASCO EQUIPMENT!
Circulator Parts (ECF Models)
Circulator (Unit with cord or stub cord) (1)
Float in separate box (1)
1. Float (1)
2. Base Strap (1)
3. Adjustment Bracket (1)
4. Angle Bracket (3)
5. Draw Band (1)
6. U-Bracket (2)
7. Spacer Bracket (2)
8. 1/4” x 1/2” Stainless Steel Bolt (8)
9. 1/4” x 1” Stainless Steel Bolt (3)
10. 1/4” x 1-1/4” Stainless Steel Bolt (2)
11. 1/4” Stainless Steel Lock Nut (8)
12. 1/4” Stainless Steel Hex Nut (2)
13. 1/4” Stainless Steel Lock Washer (5)
14. 50’ Black Nylon Ropes (2)
15. Nylon Tie (1)
Note: Extra hardware may be included
STEP NINE
The user supplied power cord should now be attached
to the stub cord by lining up the male and female
halves of the disconnect and hand tightening the blue
collar. On these cords, the Additional Strain Relief
should be attached to one of the lower float brackets.
If there is not a Strain Relief, use the Nylon Cable Tie
provided to secure the cord to a rope to prevent dam-
age by the propeller. If installing a new Quick Dis-
connect, please refer to Quick Disconnect instructions.
Installation Instructions
STEP ONE
Use the ropes to position the Unit in the desired loca-
tion in the pond/lake (secure the cord near power
source to prevent it from being dragged into the wa-
ter). Anchor the ropes or secure them to the shoreline
so the ropes are free of slack, but not tight. To prevent
twisting of the unit due to torque, you should place the
anchor at least 3m from the float for every 1 meter of
depth (Ex. A 3m deep pond would require an anchor
9m horizontally from the float.) For ease of removal,
you may choose to keep at least one anchor within
reach from shore, just below the water’s surface.
Correct Anchoring
Incorrect Anchoring
STEP TWO (ALTERNATE INSTALLATION)
In ponds where the water level fluctuates significantly,
you may need to suspend a small weight (30cm of

9
STEP FOUR
Place one of the three Angle Brackets (Part B4)per-
pendicular to the Base Strap at the front end of the
Base Strap. One of the two center holes of the Angle
Bracket should be positioned over the hole in the Base
Strap and the threaded hole in the Float. Secure the
Angle Bracket to the Float using three 1/4” x 1/2”
Stainless Steel Bolts and three Stainless Steel Lock
Washers. (See photos for specific instructions based
on the size circulator purchased.) Tighten all hardware
at this time with the 7/16” (11mm)socket and wrench.
Models 2400
& 3400 - Angle
posterior to bolts.
Model 8400
& 4400 Angle
anterior to bolts.
STEP FIVE
With a felt-tip marker, draw three to four marks
around the circumference of the motor housing at the
appropriate measurement from the back (or bottom) of
the motor housing given:
2400: 3/4” (1.9cm)
3400: 3-3/8” (8.57cm)
4400: 5-1/2” (14 cm)
8400: 7-1/2” (19 cm)
STEP SIX
Place the two U-Brackets (Part B6) directly across
from each other (180O) over the top ring of the motor
cage. The cord clamp on the cage should be 90Ofrom
each of the U-Brackets
Circulator Tools & Supplies Needed
A. Anchors or stakes for installing unit (2)
B. 208-240V Electrical Supply near pond on a post
C. 30cm pieces of 2.54cm galvanized pipe for weight-
ing ropes (optional) (3)
D. 9/16” (14mm) & 7/16” (11mm) Nut Driver
E. 9/16” (14cm) & 7/16” (11mm) Socket
F. Adjustable crescent wrench
G. 7/16” Wrench (1)
H. 7/16” Socket & Wrench (1)
I. Felt-tip marker (1)
Circulator (ECF Model) Assembly
STEP ONE
Remove all contents from package and place on a
clean, flat surface. Inspect the shipment for any dam-
ages. Make sure you have all the parts needed.
STEP TWO
Position the Float (Part B1)upside down (lengthwise
channels facing up) and place the Base Strap (Part B2)
so the three holes in the Base Strap align with the three
threaded holes that comprise the lengthwise midline of
the Float.
STEP THREE
Position the Adjustment Bracket (Part B3) over the
two holes at the back end of the Float and Base Strap.
Loosely secure the Adjustment Bracket to the Float us-
ing two 1/4” x 1/2” (Part B8) Stainless Steel Bolts and
two Stainless Steel Lock Washers (Part B13). (See
photo above for orientation.)

10
Band touches the marks drawn in Step Five. There is
no front or back to the Draw Band itself - it is revers-
ible. Orient the arm of the Draw Band so it aligns
with the cord clamp on the cage of the motor housing
and is parallel to the Angle Brackets attached in Step
Eight. Secure using a 1/4” x 1” Stainless Steel Bolt
and a 1/4” Lock Nut. (See photo in next column)
STEP TEN
Attach the Angle Bracket on the motor to the Angle
Bracket on the Float using two 1/4” x 1/2” Bolts and
two 1/4” Lock Nuts (one set for each Bracket). See
photos for orientation based on model size. Also, the
cord clamp on the cage should be oriented toward the
Float.
2400 & 3400 4400 & 8400
Angle towards back Angle Towards front
STEP ELEVEN
Attach the Draw Band on the motor to the Adjustment
Bracket on the Float using a 1/4” x 1/2” Bolt and a
1/4” Lock Nut. Select one of the five possible posi-
tions to mount the Draw Band for your preferred
direction of flow. We do not recommend the two outer
(most upward and most downward) mounting posi-
tions for 8400 models.
Horizontal Angled Up Angled Down
STEP TWELVE
Attach the Ropes to the front (on the cage) and back
.
1/4” x 1”
Bolt and
Locking
Nut
Power Cord1/4” x 1-1/4”Bolt
and Nut
1/4” x 1”
Bolt and
Locking
Nut
1/4” x 1-1/4”Bolt
and Nut
STEP SEVEN
Insert the Spacer Bracket (Part B7)under the U-Brack-
et and inside the cage. Secure this assembly using one
1/4” x 1” Bolt (Part B9) and a 1/4” Lock Nut (Part
B11), and one 1/4” x 1-1/4” Bolt (Part B10) and a 1/4”
Hex Nut (Part B12). The longer bolt should be on the
side of the U-Bracket that is closer to the cord clamp.
Tighten the hardware using the 7/16” (11mm) wrench
and socket & wrench until the U-Bracket clamps
firmly around the cage (U-Bracket should pull together
slightly). Repeat with the second U-Bracket.
STEP EIGHT
Attach an Angle Bracket to each of the longer (1-1/4”)
bolts on the U-Brackets (See photo for orientation)
with a 1/4” Lock Nut.
2400 & 3400 4400 & 8400
STEP NINE
Wrap the Draw Band (Part B5) around the motor
housing and position so that the back of the Draw

11
OBSERVATION: Operating equipment should be
observed on a regular basis (daily, if possible) for any
reduction or variation in performance. If a change
in performance is observed, the equipment should be
disconnected from power and inspected for any ma-
terial that may have clogged the system or wrapped
around the shaft of the motor, especially plastic bags
and fishing line. Even though Kasco Aerators &
Circulators are among the most clog-resistant on the
market, it is impossible to protect against all items that
can clog equipment and still maintain a flow of water.
These materials can be very damaging to the equip-
ment under continued operation and must be removed
as soon as possible. ALWAYS UNPLUG THE UNIT
BEFORE ATTEMPTING TO REMOVE CLOGS.
WINTER STORAGE: In regions where there is
significant freezing in the wintertime, Aerators should
be removed from the water to protect them from the
expansion pressure of the ice. In many areas, Aerators
will keep some amount of ice open through the winter.
However, when the water is thrust into the air, it is
exposed to the colder air temperatures longer and can
actually make ice thicker on the pond/lake. Storage
over winter is best in a location that is out of the sun
and cool, but above 0OC.
CLEANING: Equipment should be removed from the
water at least once per year (at the end of the season
in cold climates) to clean the exterior of the system,
especially the stainless steel motor housing (can). The
motor housing is the surface that dissipates heat into
the water and any algae, calcium, etc. build-up will be-
come an insulator that blocks heat transfer. In warmer
regions it is recommended that the motor is removed
and cleaned at least two to three times per year de-
pending on conditions. In most cases a power washer
will be sufficient if the unit and algae are still wet.
SEALAND OIL REPLACEMENT: This is a sealed
motor assembly and seals will wear out over time
(similar to break pads on a car). Replacement of the
seals and a change of oil after three years may add
longevity to the operation of the motor, saving you the
cost of more expensive repairs. In warmer climates
where the equipment runs most or all of the year, it is
a good idea to replace seals more regularly than you
would need to in colder climates where the unit is
removed from the water for several months.
(around the Draw Band) of the motor. At this time,
use the Nylon Tie provided to connect the power cord
and front Rope to prevent the cord from tangling in the
prop. Also, if the power cord has a Quick Disconnect
and Additional Strain Relief install the Quick Discon-
nect and Strain Relief per instructions.
STEP THIRTEEN
Float the circulator in the water and position where
desired. Tie the front Rope to a stake on the shore or
weight. If a weight is used sink weight in front of unit
so rope is taught. (Circulators create great force, make
sure weight is enough to prevent movement.) Tie back
Rope to a stake on opposite shore or weight. Sink
weight behind the unit so rope is taught. At this time
take up any slack in the line.
STEP FOURTEEN
You can now connect the Circulator into the RCD
protected power source at the ponds edge.
Maintenance Recommendations
Under No Circumstances should anyone enter
the water while a fountain is operating. Turn Off and
Disconnect electrical power prior to any Maintenance
or Servicing
RCD (Residual Current Device) or GFCI are a safety
feature that can also alert you to electrical leaks in the
equipment. It is extremely important to test the RCD
upon installation, each reinstallation, and monthly
thereafter to ensure proper operation. If you have
repeat, consistent trips on your ground fault, the equip-
ment should be disconnected and removed from the
water. The power cord should be inspected for dam-
age and you should call a Kasco Marine distributor or
representative for further instructions.
If the supply cord becomes damaged, it must be
replaced by an authorized service center, or similarly
qualified persons in order to avoid a hazard.

12
ZINC ANODE: A Sacrificial Zinc Anode is supplied
on the shaft of all Kasco 50Hz Aerators & Circula-
tors for protection of the equipment from corrosion
and electrolysis. The zinc anode should be replaced
if reduced to half the original size or if white in color.
Corrosion from electrolysis is more commonly associ-
ated with saltwater or brackish water, but as a matter
of precaution, it is important to periodically check the
zinc anode in all installations (at least every two to
three months).
Seal replacement and all other repair services should
be performed by Kasco Marine or a Kasco trained
Authorized Repair Center. Please contact your Kasco
Marine, Inc. distributor or representative for your
nearest Authorized Repair Center.
Troubleshooting Tips
For more tips and information contact your Kasco
distributor or go to
www.kascomarine.com (Under the technical tab)
Kasco Marine, Inc.
800 Deere Rd.
Prescott, WI 54021
U.S.A.
Phone 00+1+715+262+4488
Fax 00+1+715+262+4487
www.kascomarine.com
884150

Belangrijke veiligheidsaanwijzingen . . . . . .2
Specificaties van de units . . . . . .2
Installatie van de ‘Quick disconnect’-aansluiting . . . . . .2
Maten van draad en wartels . . . . . .4
Onderdelen van de 2400EAF, 3400EAF, 4400EAF . . . . . .5
2400EAF, 3400EAF, 4400EAF Montage-instructies . . . . . .5
Onderdelen van de 8400EAF, 3.1EAF . . . . . .7
Montage van de modellen 8400EAF en 3.1EAF . . . . . .7
Installatieinstructies . . . . . .8
Onderdelen van de circulatiepomp (ECF-modellen) . . . . . .9
Montage van de circulatiepomp (ECF-modellen) . . . . . .9
Aanbevolen onderhoud . . . . . .12
Tips voor het oplossen van problemen . . . . . .13
Herz. 07/10/08
Kasco Marine, Inc.
800 Deere Rd.
Prescott, WI 54021
VS
Tel.: +1-715-262-4488
Fax: +1-715-262-4487
www.kascomarine.com
Inhoudsopgave
Gebruikershandleiding
50 Hz-beluchters en
circulatiepompen

2
LET OP
KENNISGEVING (OPMERKING)
Deze internationale veiligheidssymbolen worden
overal in deze handleiding gebruikt om de eigenaar
attent te maken op belangrijke veiligheidsinformatie
en kennisgevingen in verband met het veilige en
doeltreffende gebruik van de apparatuur.
Belangrijke
veiligheidsaanwijzingen
LET OP
Personen mogen zich NOOIT in het water• bevinden terwijl de elektrische apparatuur
aangesloten en/of in werking is. Het is NOOIT
verstandig om het water in te gaan terwijl de
apparatuur in werking is.
Ga altijd uiterst voorzichtig te werk tijdens• het hanteren van elektrische apparatuur met
bewegende onderdelen.
Laat de unit NOOIT buiten het water draaien.• Hierdoor worden de afdichtingen beschadigd en
wordt een gevaarlijke situatie geschapen voor
de operator.
Wees uiterst voorzichtig in de buurt van water,• vooral koud water, bijv. in de lente, herfst en
winter, wat op zich al een gevaarlijke situatie is.
De unit mag NOOIT aan het stroom- of• lichtsnoer worden opgetild of voortgetrokken.
Als u de unit naar de zijkant van de vijver
moet trekken, gebruik hiervoor dan de
verankeringskabels.
Gebruik nooit lieslaarzen in vijvers of meren• die diep zijn, plotseling aanzienlijk dieper
worden of een sterk hellende bodem hebben of
een bodem die uit zacht materiaal bestaat.
Gebruik tijdens de installatie van uw• fontein nooit een boot die gemakkelijk kan
omslaan (zoals een kano) en volg alle regels
en voorschriften voor veiligheid op het water,
inclusief het dragen van een reddingsvest
(‘Personal Flotation Device’of ‘PFD’).
De unit wordt geleverd met een interne• aardleiding. Om het risico van elektrische
schokken te verminderen, dient u ervoor
te zorgen dat de unit op een goedgekeurde
stroomketen met aardlekschakelaar
(verliesstroomautomaat) wordt aangesloten.
De vaste bedrading moet voorzien zijn• van een ontkoppelingssysteem, dat aan
zowel de plaatselijke als de nationale
bedradingsvoorschriften voldoet.
Raadpleeg een bevoegd elektricien voor de• elektrische installatie.
Specificaties van de units
Model Voltage Bedrijfs-
stroom-
sterkte
Initiële
aanloopstroom
2400EAF 208-240 2,2@240V 6@240V
3400EAF 208-240 3,4@240V 9@240V
4400EAF 208-240 3,7@240V 20@240V
8400EAF 208-240 8,0@240V 40@240V
3.1EAF 208-240 11,9@240V 60@240V
2400ECF 208-240 2,2@240V 6@240V
3400ECF 208-240 3,4@240V 9@240V
4400ECF 208-240 3,7@240V 20@240V
8400ECF 208-240 8,0@240V 40@240V
Installatie van de ‘Quick
disconnect’-aansluiting
Belangrijk – vóór de installatie aandachtig lezen
Alvorens met de installatie van de connector te
beginnen, dient u deze instructies aandachtig te lezen
en te begrijpen, zodat u het connectorsysteem volledig
waterdicht en elektrisch veilig kunt installeren. IN
GEVAL VAN TWIJFEL DIENT U EEN BEVOEGD
ELEKTRICIEN TE RAADPLEGEN.
De contrastekker (het vrouwelijke deel) van de
connector hoort rechtstreeks op de stroomvoorziening
aangesloten te zijn. De stekker (het mannelijke deel)
van de connector hoort aan het te voeden apparaat
vast te zitten. 50 Hz-units worden af fabriek geleverd
met de stekker (het mannelijke deel) van de connector
geïnstalleerd. Een goede afdichting is alleen mogelijk
als er gladde, ronde kabel wordt gebruikt.

3
Stekker van de connector (af fabriek geïnstalleerd
op het korte snoer)
Stekker Behuizing Wartel Wartelmoer
Contrastekker (door gebruiker geïnstalleerd)
Contrastekker Behuizing Wartel Wartelmoer
Opmerking:
Witte wartel voor buitendiameter van 9-11 mm
Gele wartel voor buitendiameter van 13-15 mm
Instructies voor samenstelling/bedrading
Verwijder de contrastekker uit de behuizing van de
connector. In het midden van de contrastekker zit een
sleuf voor een platte schroevendraaier.
Opmerking: de stekker en de contrastekker
hebben LINKS SCHROEFDRAAD; dus RECHTSOM
draaien om te verwijderen.
STAP 2
Haal de wartelmoer en de wartel uit de achterkant
van de behuizing en breng deze (de wartelmoer en de
wartel) op de kabel aan. Het trapvormige uiteinde van
de wartel moet naar de wartelmoer gericht zijn (zie
afbeelding). Trapvormig uiteinde
STAP 3
Maak de kabel klaar door de draaduiteinden te
strippen zoals afgebeeld.
Strippen van de draden
STAP 4
Steek de gestripte draaduiteinden in de contacten
achterop de contrastekker en draai de schroeven
volledig aan (zie afbeelding voor de juiste plaatsing
van de draden).
Afbeelding 5:
Aansluitingen van de draden
Bruine draad -- contact L
Blauwe draad -- contact N
Groen/gele draad -- contact E
Trek nadat u de draden
juist hebt aangesloten, de kabel met de contrastekker
erop weer in de behuizing en zet de contrastekker met
een schroevendraaier stevig vast.
Opmerking: LINKS SCHROEFDRAAD; draai
de contrastekker dus LINKSOM vast.
STAP 5
Maak de bijgeleverde harsset klaar door het dopje van
het harsbuisje te verwijderen en het tuitje op het buisje
aan te brengen. Draai het tuitje vervolgens totdat het
vastklikt.
Plunjer Buisje met hars Tuitje
Druk alvorens de hars op de ‘Quick disconnect’-
aansluiting aan te brengen, de plunjer gelijkmatig
voldoende in om een kleine hoeveelheid hars te
spuiten; dit is nodig om de uit 2 componenten
bestaande epoxyhars naar behoren te mengen. Breng
vervolgens voldoende hars in de behuizing aan om
de draden en de contacten te bedekken. De hars
moet ongeveer 3 mm van de kabelmantel bedekken.
Opmerking: als er teveel hars wordt aangebracht, kan

4
geïnstalleerd (niet op het door Kasco geleverde
korte snoer met de stekker). De trekontlasting moet
ongeveer 15 cm van de ‘Quick disconnect’-aansluiting
worden gemonteerd. Steek hiervoor het smalle
uiteinde van de lange klem met de ketting eraan
in het brede uiteinde van de korte klem. Gebruik
een rubberen hamer om deze twee stukken stevig
aan elkaar te bevestigen. Het geheel kan met een
nylon kabelbinder aan het snoer worden bevestigd.
Vervolgens kan de ketting aan het drijflichaam worden
bevestigd.
Maten van draad en wartels
De onderstaande tabel toont de wartels die met
verschillende snoermaten moeten worden gebruikt.
Deze maten zijn gebaseerd op de buitendiameter
van het snoer. Alleen glad, rond snoer moet worden
gebruikt.
Tabel met maten voor de Kasco 50 Hz-’Quick
disconnect’-aansluiting:
Wartel Buitendiameter snoer
Grijs 7-9mm
Wit 9-11mm
Zwart 11-13mm
Geel 13-15mm
Tabel draaddikten Kasco 50 Hz-apparatuur
Model Snoerlengte
10m 30m 60m 90m
2400EAF 1,5mm21,5mm22,5mm22,5mm2
2400ECF 1,5mm21,5mm22,5mm22,5mm2
3400EAF 1,5mm21,5mm22,5mm22,5mm2
3400ECF 1,5mm21,5mm22,5mm22,5mm2
4400EAF 1,5mm21,5mm22,5mm24mm2
4400ECF 1,5mm21,5mm22,5mm24mm2
8400EAF 1,5mm22,5mm24mm26mm2
8400ECF 1,5mm22,5mm24mm26mm2
3.1EAF 1,5mm22,5mm26mm26mm2
het overschot in de contrastekker worden geperst,
waardoor de stekker er niet goed in zou passen.
Opengewerkte
afbeelding van het
vrouwelijke gedeelte
van de ‘Quick
disconnect’aansluiting
met kleurloze hars. Let
op de hoeveelheid hars
op de kabelmantel.
STAP 6
Schuif de wartel en de wartelmoer langs de kabel in de
behuizing en draai de wartelmoer stevig vast. Hiervoor
is het niet nodig de epoxyhars eerst te laten drogen.
STAP 7
Wanneer deze helft van het ontkoppelingssysteem
klaar is, kunnen de twee helften op elkaar worden
aangesloten. Steek de stekker in de contrastekker en
draai de grote blauwe moer stevig vast. De blauwe
moer moet met de hand worden vastgedraaid. Zie de
onderstaande afbeelding.
Opmerking: nadat de blauwe moer is vastgedraaid, is
er hier een kleine ruimte zichtbaar.
Als dit bij verwijdering aan het einde van het seizoen
gewenst is, kan de ‘Quick disconnect’-aansluiting
worden beschermd met de bijgeleverde waterdichte
afdekking. Maak hiervoor de ‘Quick disconnect’-
aansluiting los en breng de afdekking in de helft met
de grote blauwe moer aan. Draai deze vervolgens
stevig vast.
Trekontlasting
De trekontlasting is nodig om de ‘Quick disconnect’-
aansluiting te beschermen tegen beschadiging door
overmatige trekkracht. De trekontlasting moet op
het door de gebruiker verzorgde snoer worden

5
2400EAF, 3400EAF, 4400EAF
Montage-instructies
STAP 1
Zet de motorbehuizing verticaal (met de roestvrij
stalen cilinder omlaag) op een plat oppervlak. Houd
de motorbehuizing verticaal en schuif het drijflichaam
(onderdeel 2) over de pompbehuizing met het
oppervlak met het Kasco-logo omhoog.
logo
Zorg ervoor dat het drijflichaam op de bovenste ring
van de korf rust.
STAP 2
Zorg ervoor dat het geheel naar behoren past door het
drijflichaam voorzichtig rondom de motorbehuizing
te draaien totdat het ‘vastklikt’, de boutgaten in
het drijflichaam overeenkomen met die op de unit
en de sleuf op één lijn staat met het snoer. Zie de
onderstaande afbeelding van de onderkant van het
drijflichaam. boutgaten
sleuf voor
snoer
STAP 3
Gebruik één van de cilinderkopschroeven met
kruiskop van 1/4-20 x 3 1/2 inch (onderdeel 3), een
splitring van 1/4 inch (6 mm) (onderdeel 4) en een
vlakke sluitring van 1/4 inch (6 mm) (onderdeel 5)
om het drijflichaam te bevestigen. Let op: de splitring
hoort tussen de boutkop en de vlakke sluitring. Steek
de schroef met de pasringen door het boutgat in het
drijflichaam.
Breng een bevestigingsclip (onderdeel 6) onder de
Onderdelen van de 2400EAF,
3400EAF, 4400EAF
(Unit met snoer of kort snoer) (1)1. Drijflichaam (voorzien van twee verankeringskabels2. van 17 m (50 ft.)) 1
Cilinderkopschroef met kruiskop, 1/4-20 x 3 1/2 inch3. (83 mm) (4)
Splitringen van 1/4 inch (6 mm) (4)4. Vlakke sluitring, 1/4 inch (6 mm) (buitendiameter 3/45. inch – 19 mm) (4)
Bevestigingsclips drijflichaam (4)6.
(facultatief)
Zeskantkopbout, 3/8-16 x 1-3/8 (2)7. Vlakke sluitring, 3/8 inch (9,5 mm) (4)8. Kussentje voor het onderste scherm (3)9. Onderste scherm10. Bevestigingsclips onderste scherm (2)11. Nylon borgmoer, 3/8-16 (2)12.
1
2
3
4
5
7
8
6
9
10
11
12

6
bovenste ring van de korf aan. De clip is voorzien van
een U-vormige inkeping, waar de bovenste ring van de
korf in past. Draai vervolgens een schroef van 1/4-20
x 3 1/2 inch in de bevestigingsclip.
Bevestigingsclip drijflichaam
Bevestigingsclip drijflichaam
Draai de schroef met een kruiskopschroevendraaier
goed aan en herhaal deze procedure voor de overige 3
schroeven
.
STAP 4
Draai het gemonteerde geheel ondersteboven zodat
de bovenkant van het drijflichaam (met het logo) op
het platte oppervlak rust. Breng het onderste scherm
(onderdeel 10) onderop het drijflichaam aan. Zorg
ervoor dat de brede opening in het scherm tegen het
drijflichaam aan staat en dat de 3 handgrepen op
het scherm de kabels niet belemmeren. Breng de
3 kussentjes voor het onderste scherm (onderdeel
9) onder het scherm aan en bovenop de 3 hiervoor
bedoelde verheffingen onderop het drijflichaam.
Kussentje voor het onderste scherm
STAP 5
Gebruik een roestvrij stalen bevestigingsclip
(onderdeel 11), een bout van 3/8-16 x 1-3/8 (onderdeel
7), twee vlakke sluitringen van 3/8 inch (9,5 mm)
(onderdeel 8) en een nylon borgmoer van 3/8-16
(onderdeel 12) om het scherm op het drijflichaam te
monteren. Plaats de bevestigingsclip zodanig dat de
twee tanden zich aan weerszijden van een draad in
het scherm bevinden. Breng de bout met sluitring aan
met de kop naar de bovenkant van het drijflichaam
(die nu omlaag gericht is). Breng de tweede sluitring
en de nylon borgmoer op de bout aan en draai deze
vast (plaats hiervoor de ratelsleutel met dopsleutel van
9/16 inch (14 mm) op de moer en de sleutel van 9/16
inch (14 mm) op de kop van de bout). Draai het geheel
stevig aan en herhaal deze procedure voor de andere
clip.
STAP 6
Zet de eenheid weer rechtop. Nu kunt u als het
snoer van een metalen trekontlasting voorzien
is de ketting hiervan in één van de gaten bij het
kabelbevestigingspunt aanbrengen. De ketting zal
gemakkelijk passen als deze vanaf de onderkant
of de bovenkant van het gat wordt aangebracht.
Vanaf de zijkant van het gat past hij niet. Gebruik de
bijgeleverde nylon kabelbinder (onderdeel I) om het
stroomsnoer in een gevormd gat in het drijflichaam
vast te zetten (dit om beschadiging van het snoer te
voorkomen als er geen trekontlasting op aanwezig
is). Als het snoer wel een trekontlasting heeft, kunt
u de nylon kabelbinder overslaan. Op snoeren met
een ‘Quick disconnect’-aansluiting moet deze naar
behoren worden aangedraaid om lekkage tegen
te gaan. Zie als u een nieuwe ‘Quick disconnect’-
aansluiting gaat installeren het gedeelte ‘Installatie van
de ‘Quick disconnect’-aansluiting’. Ga als u klaar bent
om de unit in de vijver te installeren, naar het gedeelte
‘Installatieaanwijzingen’.

7
Montage van de modellen
8400EAF en 3.1EAF
STAP 1
Verwijder de gehele inhoud uit de doos en plaats alles
op een schoon, plat oppervlak. Inspecteer het geheel
op schade. Overtuig u ervan dat u alle benodigde
onderdelen hebt.
STAP 2
Plaats de drie segmenten van het drijflichaam
(onderdeel B1) rechtop (plug onderop) zodat de
hiervoor bedoelde gedeelten elkaar naar behoren
overlappen en druk de drie segmenten losjes op elkaar,
zodat deze een ring vormen.
Bovenkant drijflichaam Onderkant
drijflichaam (plug)
STAP 3
Breng één van de beugels voor bovenop het drijflichaam
(onderdeel B2) zodanig aan dat de boutgaten in de beugel
overeenkomen met de boutgaten in de twee samengevoegde
segmenten van het drijflichaam en steek twee zwart
gecoate bouten van 9 inch (229 mm) (onderdeel B4) door
het geheel heen. Terwijl u de bout hier helemaal doorheen
duwt, is het wellicht nodig de plaatsing van de segmenten
van het drijflichaam enigszins aan te passen. Forceer de
bout niet. Herhaal deze procedure voor de andere twee
overlappende gedeelten.
STAP 4
Keer het samenstel ondersteboven en breng de beugels
voor onderop het drijflichaam (onderdeel B3) op de bouten
aan (de uiteinden hiervan horen nu uit de onderkant van
het drijflichaam te steken). Breng de zes borgmoeren
(onderdeel B5) losjes op de uiteinden van de bouten aan;
draai ze nog niet vast. Verbind de bovenste en de onderste
beugels met behulp van drie bouten van 1/4 x 3/4 inch (6
x 19 mm) (onderdeel B7), drie borgringen van 1/4 inch (6
Onderdelen van de 8400EAF,
3.1EAF
B2. Groot ringvormig drijflichaam
Zie de onderstaande afbeelding.
1. Segment van het drijflichaam (3)
2. Beugel voor bovenop drijflichaam (3)
3. Beugel voor onderop drijflichaam, met kabel (3)
4. Bout van 9 x 3/8 inch (229 x 9,5 mm) (6)
5. Borgmoer van 3/8 inch (9,5 mm) (6)
6. Montagebeugel voor de motor
7. Bout van 1/4 x 3/4 inch (6 x 19 mm)
8. Borgring van 1/4 inch (6 mm)
9. Moer van 1/4 inch (6 mm) (3)
10. Onderste scherm (1 - facultatief)
11. Bevestigingsclips onderste scherm (3 - facultatief)
Opmerking: er is mogelijk extra hardware
bijgeleverd.
Benodigd gereedschap, enz:
A. Ankers of staken voor installatie van unit (2 of 3,
afhankelijk van unit)
B. Stroomvoorziening (208-240 V) nabij vijver, op
paaltje
C. Twee (of drie, afhankelijk van het model) 30 cm
lange stukken gegalvaniseerde buis (doorsnede 2,54
cm) voor verzwaring van de kabels (facultatief)
D. Dopschroevendraaiers van 9/16 inch (14 mm) en
7/16 inch (11 mm)
E. Ratelsleutel met dopsleutel, 9/16 inch (14 mm) en
7/16 inch (11 mm)
Verstelbare moersleutel

8
inch (14 mm).
Opmerking: er is mogelijk extra hardware
bijgeleverd.
STAP 7
Bevestig nu het door u verzorgde stroomsnoer aan het
korte snoer door de mannelijke helft in de vrouwelijke
helft van de ‘Quick disconnect’-aansluiting te steken
en de blauwe ring met de hand vast te draaien. Bij
deze snoeren hoort de trekontlasting aan één van
de onderste beugels op het drijflichaam te worden
bevestigd. Als er geen trekontlasting is, dient u het
snoer met de bijgeleverde nylon kabelbinder aan één
van de kabels te bevestigen om beschadiging door de
propeller te voorkomen. Zie als u een nieuwe ‘Quick
disconnect’-aansluiting gaat installeren het gedeelte
‘Installatie van de ‘Quick disconnect’-aansluiting’.
Installatieinstructies
STAP 1
Breng de unit met de kabels op de gewenste plaats in de
vijver/het meer aan (maak het snoer bij de krachtbron vast
om te voorkomen dat dit in het water wordt getrokken).
Maak de kabels op zodanige manier in de bodem of op de
oever vast dat zij geen speling hebben, maar ook niet te
strak staan. Om verdraaiing van de unit door wringkracht
tegen te gaan, hoort u de verankering voor elke m diepte
ten minste 3 m van het drijflichaam te plaatsen (bijv.: in
een 3 m diepe vijver hoort de horizontale afstand tussen
de verankering en het drijflichaam ten minste 9 m te
bedragen). Om verwijdering te vergemakkelijken, is het
wellicht verstandig om ten minste één verankering zodanig
aan te brengen dat deze vanaf de oever bereikbaar is (net
onder het wateroppervlak).
mm) (onderdeel B8) en drie moeren van 1/4 inch (6 mm)
(onderdeel B12) en draai ze vast met de ratelsleutel met
dopsleutel van 7/16 inch (11 mm).
STAP 5
Zet de unit weer ondersteboven en breng de motoreenheid
(met de roestvrij stalen cilinder omhoog en de zwarte
pomp omlaag) in het midden van het drijflichaam aan.
Bevestig de motor aan het drijflichaam met de hiervoor
bedoelde montagebeugels (onderdeel B6). De uitsparing
in het midden van de montagebeugels voor de motor past
over de bovenste ring van de korf en elke montagebeugel
voor de motor moet in de onderste twee gaten in de
overeenkomstige beugel op het drijflichaam worden
bevestigd.
Gebruik hiervoor de bouten van 1/4 x 3/4 inch (6 x 19 mm)
en de borgringen van 1/4 inch (6 mm) en draai deze vast
met de ratelsleutel met dopsleutel van 7/16 inch (11 mm)
(zie de afbeeldingen). Opmerking: Als de montagebeugel
voor de motor moeilijk tussen de korf en de behuizing van
de fontein past, kunt u hier een schroevendraaier tussen
steken en voorzichtig wat meer ruimte maken.
STAP 6 (Onderste scherm (facultatief): afzonderlijk
verkrijgbaar)
Plaats het onderste scherm (onderdeel B10) zodanig
op het drijflichaam dat de (cilindervormige)
motorbehuizing in de grote opening in het midden
van het scherm past. Verwijder de binnenste drie
borgmoeren van de bouten van 9 inch (229 mm) en
breng de bevestigingsclips voor het onderste scherm
(onderdeel B11) op de bouten aan (zie afbeelding).
Alvorens de borgmoeren opnieuw te monteren, kunt u
het stroomsnoer onder het onderste scherm schuiven
op het verbindingspunt tussen twee segmenten van
het drijflichaam. Breng de binnenste drie borgmoeren
weer aan en draai alle borgmoeren van 3/8 inch (9,5
mm) vast met de ratelsleutel met dopsleutel van 9/16
This manual suits for next models
8
Table of contents
Languages:
Popular Lawn And Garden Equipment manuals by other brands

Titan Attachments
Titan Attachments ATVWC3 Operator's manual

LITTLE BEAVER
LITTLE BEAVER KT2400B Operator's manual

Smithers-Oasis
Smithers-Oasis FloraLife Blend Center Installation and user instructions

BROWIN
BROWIN 730703 instruction manual

ENCLO
ENCLO EC18024 Assembly instructions

Gecko
Gecko IT560 instruction manual