FEATURES
Die casting stainless steel tank
Industrial grade integrated circuit
0~80℃temperature range
1~99 minutes working time
Degassing and degreasing function
33KHz & 40KHz for intensive rinse
Auto Stand-by, Sleep, and wake up by one key-press Mode
Digital controller of high-precision and a long service-life
ULTRASONIC CLEANER
USER MANUAL

2
Thank you for purchasing this ultrasonic cleaner. Please take some time to read these operating instructions before use
and keep them for future reference. Failure to follow these instructions may lead to serious artificial damages to the
product.
ULTRASONIC PRINCIPLE
PREPARATION:
1. Carefully unpack the cleaner, remove all packing materials and check whether any
parts have become loose or damaged during transit.
Contents:
a: Main machine b: Sound proof lid c: Power lead
d: Outlet filter e: Mesh basket (Optional) f: Manual
2. Place the cleaner on a flat, clean surface and ensure that the cooling fan will get
adequate ventilation, and that all controls are set to off, and the drain tap is
closed.
3. Ensure that the power lead is securely plugged into the cleaner, and that no part of
the lead is likely to contact with moisture.
4. Carefully fill at least 7cm depth of the tank with a solvent solution. Based on
cleaning requirements, we recommend to use a small amount of cleaning solution
because this will help increase the cleaning performance. Now the cleaner is ready
for use.
Ultrasonic cleaning is based on the cavitation effect caused by
high frequency ultrasonic wave vibration signal in the fluid.
Microscopic bubbles are formed, and then implode violently
causing the cavitation which create an intense scrubbing action
on the surface of the item being cleaned. The bubbles are small
enough to penetrate microscopic crevices, cleaning them
thoroughly and consistently.
Ultrasonic cleaning is extremely effective at removing dirt and
grime which would normally require tedious manual cleaning by
hand. It has been used to clean a wide variety of instruments and
mechanical parts such as carburetors, returning them to almost
“like new” condition without damage to delicate parts.
Attention
A) While the machine is working normally, the syntony of the ultrasonic wave and tank
gives a well-proportioned sound with no shudder on the surface of the water but sprays
generated by the tiny bubbles. If there are discontinuous surges, please add or reduce a
little of washing solution in the tank to stop the surges, which is good for get a better
cleaning effect.
B) Please don’t make the machine work for a continuous long time (not more than 60
minutes) as possible as you can because a long-time working will raise the temperature of
the case, accelerate the burn-in process of inner electronic components and parts.

3
SAFETY PRECAUTIONS
This device can not be used by individuals with limited physical knowledge, or the
mental disabled, or those lacking experiences or knowledge, such as children, unless
they are supervised by an individual who can take charge of their safety or have
received training in operating the device .
1) DO NOT run the cleaner continuously for more than one hour at a time because it
can damage the internal components.
2) DO NOT operate the unit without fluid in the tank. Always ensure that the fluid is no
higher than the max mark and no lower than the minimum depth of 7cm.
3) DO NOT drop any item into the tank because it may damage the transducer. Always
place items gently into the tank and use the basket whenever possible.
4) The more items you place in the cleaning bath, the less cleaning efficient you can
get. Leaving enough spaces among items rather than overlapping them is
recommended.
5) Do keep the lid on during use. This will prevent splashes and reduce evaporation
of the fluid.
6) Never immerse the machine or power cord in water or other liquid.
7) DO NOT touch the power plug with wet hands, especially when inserting or
removing the plug.
8) DO NOT touch the unit if the machine has fallen into water during operation.
Remove the power plug from the socket firstly.
9) DO NOT disassemble the machine if you are not professional.
10) UNPLUG the power source while filling or emptying the tank.
11) DO NOT spray water or liquid over the device and the control panel.
12) DO NOT operate the cleaner without proper grounding.
13) DO NOT place the device on a soft surface where the vents can be blocked.
14) Always turn the heater off after using as leaving it on can make the fluid evaporate
and damage the internal components.
15) Take care when adding or removing items from the cleaning tank as the splashed
fluid is likely to be hot and damage the internal components. Any splashed fluid
must be dried immediately.
16) In case of emergency or failure to follow the aforementioned items, disconnect the
mains supply by removing the plug from the mains socket.
Keep it away from children !
Please read the following items very carefully as failure to
comply with them may invalidate your guarantee

4
APPLICATIONS
This list is almost endless. Provided the product is non porous and can normally be
immersed in water, they can be thoroughly cleaned. Here are some examples:
Jewelry especially gold, silver & platinum
Watchstraps
Coins and other collectibles
PCB Boards etc
Engine/Model parts
Toothbrushes & Dentures
Electrical components
Make-up cases
Diesel injection pumps
Printer heads and toner cartridges
Motorcycle radiators
Vehicle differentials
Milking parlor equipment
Golf clubs&grips&golf balls
Horse bits&stirrups &horse brasses
Tattoo needles
Surgical equipment
Motorcycle engine crank cases
Engine cylinder heads
Turbochargers
Bicycle derailleurs
Knives, bayonets and other militaria
Gun and gun components
Ultrasonic cleaning is not recommended to be used to clean the following gemstones:
Opal, Pearl, Emerald, Tanzanite, Malachite, Turquoise, Lapis and Coral.
OPERATION
1. Fill the stainless steel tank with cleaning solution; Plug the power lead into
grounded outlet; After power-on, the temperature displays the actual environmental
temperature, LED displays 3 minutes (default ultrasonic time).
2. Time setting: Press the “TIME+/TIME- ”shortly at a time means time
increase/reduce 1min at a time, press and hold time switch continuously will
increase/reduce by 10mins. The cleaning stops when the timer counts down to 00:00. If

5
the unit needs to be stopped before the timer runs up, press “Ultrasonic frequency”
button.
NOTE: Do not run the cleaner continuously for more than one hour
3. Temperature setting: Press “temperature+/temperature-”shortly at a
time means time increase or reduce 1℃at a time, press and hold time switch
continuously will increase/reduce by 10℃. Usually, the best cleaning temperature is
within 40℃to 60℃.
4. After time and heat setting, press “Heating”or “ultrasonic”button to start both
function. If press the “ultrasonic “again , the ultrasonic function will stop , and the heating
function will stop at the same time. If want to keep heating, need to press “heating”
button again.
5. Degas mode: work intermittently,i.e., 6s “ON”+ 2s “OFF”working mode. It can
clean items deeply and efficiently.
6. Empty the tank and clean both the outside and inside of the cleaner with a clean
and dry cloth for next use.
NOTE: Do not pour water out until it’s cooling, because of hot water will hurt you
and also empty burn will damage the machine itself.
DIFFERENT WAYS OF CLEANING
Gennral Cleaning—use only water to clean under the temperature of about 50℃;
Enhanced Cleaning—add few drops of standard cleaning solutions, liquid soap, or
detergent, or any other non-acidic cleaning agents.
Extensive Cleaning--removing tarnish, carbon & rust from non-plated metals, it is
recommended to use specific cleaning solution associated with ultrasonic cleaners.
The cleaning solution will deteriorate in effectiveness over time and use. It is important
to regularly change the fluid and carefully wash the inside of the cleaning tank in order
to preserve the effectiveness and longevity of the cleaner. Do not use corrosive or
WARNING : Strong acid or alkaline cleaning solution will cause corrosion, rust and
even puncture of tank or machine body. To solve this problem, please dilute the solution
to mild PH or use a special tank made of a specific-graded stainless steel, For example:
use SUS304 tank.

6
abrasive cleaning tools to clean the tank which must be wiped down and dried before it
can be re-connected to the electrical supply.
NOTE: If the machine starts to spark, smoke, smell of burnt electrics or displays any
other fault the operator must immediately stop the machine, and isolate it from the
electrical supply and contact the supplier. It is dangerous to use it after that.
Advantage
Ultrasonic is widely used throughout industries to remove difficult contaminants from
the parts during or after manufacturing process which might require a stage of
cleaning before the next process. In general, if an item can be cleaned with liquid, it
can be cleaned much faster and more thoroughly with an ultrasonic cleaner. Compared
with traditional solvent/scrubbing, our ultrasonic cleaners:
Are more effective at removing contaminants;
Are quicker to get a good cleaning effect;
Save labor time of employees (and subsequent labor cost);
can heat the cleaning solutions to a suitable cleaning temperature so as to
enhance the cleaning efficiency;
Have a digital controller of high-precision and a long service-life;
Are of high performance;
reduce chemicals in the cleaned stuffs;
Are environment friendly because of its recyclability.
For Better cleaning effect:
●Immerse the cleaned stuffs well into the water.
●Add a small amount of cleaning solution is added.
●Make sure that there is enough space around each stuff in the tank. The more
stuffs you place in the tank, the less efficiency you can get. It is not advised to
overlap stuffs because the ultrasonic cleaning system can not work well with
layered stuffs.
●Use a basket. Do not put stuffs directly into the bottom of the tank because that
is harmful for the inner tank. So it is better to use a suitable basket. Especially a
metal basket only absorbs about 8% ultrasonic energy.
●Choose a suitable temperature: Generally, the higher the temperature is, the
better cleaning effect the ultrasonic cleaner can make. However, when
temperature exceed 70℃~80℃, cleaning effect will be affected. So the best
temperature we suggest is 40℃~60℃.

7
SPECIFICATIONS
H: 0-80 ℃temperature range
T: 1-99 minutes working time
D: Digital display
Model
Tank Size
(mm)
Overall Size
(mm)
Volume
(L)
Power
(W)
FREQ.
(KHz)
Heating
(W)
Time
(mins)
Temp.
(℃)
DK-130S
150*140*65
190*170*195
1.3
60
33/40
100
1~99
0~80
DK-200S
150*140*100
190*170*230
2
60
100
1~99
0~80
DK-300S
240×140×100
270×170×240
3.2
120
100
1~99
0~80
DK-400S
300x155x100
312x162x218
4.5
120
100
1~99
0~80
DK-450S
300x155x100
312x162x218
4.5
180
100
1~99
0~80
DK-600S
300×155×150
330×180×310
6.5
180
300
1~99
0~80
DK-1000S
300×240×150
330×270×310
10
240
300
1~99
0~80
DK-1500S
330×300×150
360×330×310
15
360
400
1~99
0~80
DK-2200S
500×300×150
550×330×310
22
480
500
1~99
0~80
DK-3000S
500×300×200
550×330×360
30
600
500
1~99
0~80
This manual suits for next models
9
Table of contents
Popular Ultrasonic Jewelry Cleaner manuals by other brands

SUNSET
SUNSET ZOEY ZCD100 quick start guide

J D UltraSonics
J D UltraSonics sonicom ATLAS Operating and maintenance

GRE
GRE VCB08 instruction manual

Graymills
Graymills HANDI-KLEEN PL36 Operation and maintenance instructions

Ultrawave
Ultrawave QS Series instructions

Rothenberger
Rothenberger Rospeed 3F Instructions for use