Table of contents
1 User instructions ................................................................................................................ 4
1.1 User guide .................................................................................................................... 4
1.1.1 Abbreviations ..................................................................................................... 4
1.1.2 Symbols ............................................................................................................ 4
1.1.3 Target group ...................................................................................................... 4
2 Setup methods according to ISO 17664 ............................................................................ 5
2.1 References.................................................................................................................... 5
2.2 General instructions for the reprocessing of KaVo treatment units....................................... 6
2.2.1 Overview ESTETICA E50 Life reprocessing............................................................. 7
2.3 Reprocessing of the surfaces of treatment unit / upholstery ............................................... 8
2.4 Preparation of the dentist unit......................................................................................... 9
2.4.1 Reprocessing of handle and holder pad/anti-slip mat .............................................. 9
2.4.2 Reprocessing of the instrument holder of the TM table............................................ 11
2.4.3 Reprocessing of the instrument arm S table........................................................... 12
2.4.4 Setting up the 3-function and multifunction handpiece............................................ 14
2.4.5 Preparation of the instrument hoses ..................................................................... 17
2.4.6 Servicing the turbine return air filter ..................................................................... 17
2.4.7 Reprocessing of the kit for physiological saline solution ........................................... 18
2.4.8 Reprocessing KaVo ERGOcam One ....................................................................... 20
2.4.9 Reprocessing KaVo PiezoLED ............................................................................... 22
2.5 Reprocessing of the assistant unit.................................................................................... 29
2.5.1 Preparing the instrument holder ........................................................................... 29
2.5.2 Preparing the connector for the suction hose ......................................................... 29
2.5.3 Reprocessing of sieve inserts and suction hoses..................................................... 30
2.6 Preparation of the patient unit......................................................................................... 30
2.6.1 Preparation of the tumbler................................................................................... 30
2.6.2 Preparation of the tumbler holder and filler............................................................ 31
2.6.3 Preparation of the spittoon................................................................................... 32
2.7 Manual reprocessing of the water-conducting system ........................................................ 33
2.8 Automatic hygiene functions of the water conducting system ............................................. 33
2.8.1 Rinsing programme............................................................................................. 34
2.8.2 Intensive germ reduction..................................................................................... 37
2.9 Reprocessing and automatic hygiene functions of the suction system.................................. 41
2.9.1 Reprocessing of the suction system including suction hoses..................................... 41
2.9.2 HYDROclean function .......................................................................................... 41
2.9.3 Manual internal cleaning of the suction hoses at the extraction point (optional) ......... 42
2.10Preparation of the amalgam separator ............................................................................. 45
2.11Reprocessing KaVo Screen One / KaVo Screen HD ............................................................ 46
2.12Reprocessing of the service table 1568 ............................................................................ 46
3 Replacing and checking cleaning and germ reduction agents ...........................................48
3.1 Replenish OXYGENAL 6 .................................................................................................. 48
3.1.1 Replenish OXYGENAL 6 when using the water bottle............................................... 49
3.2 Check the OXYGENAL 6 concentration.............................................................................. 52
3.3 Replacing the DEKASEPTOL Gel bottle (DEKAmat assembly kit only)................................... 54
Care instructions ESTETICA E50 Life