2
ii. SAFETY WARNING! — PLEASE READ CAREFULLY
This product should be installed and serviced by a qualified technician, electrician or
electrical maintenance person familiar with its operation and the hazards involved. Proper
installation, which includes wiring, mounting in proper enclosure, fusing or other overcurrent
protection and grounding, can reduce the chance of electric shocks, fires or explosion in this
product or products used with this product, such as electric motors, switches, coils, solenoids
and/or relays. Eye protection must be worn and insulated adjustment tools must be used when
working with control under power. This product is constructed of materials (plastics, metals,
carbon, silicon, etc.) which may be a potential hazard. Proper shielding, grounding and filtering
of this product can reduce the emission of radio frequency interference (RFI) which may
adversely affect sensitive electronic equipment. If information is required on this product,
contactourfactory. Itisthe responsibilityoftheequipmentmanufacturerandindividualinstaller
to supply this safety warning to the ultimate user of this product. (SW effective 11/92)
ThiscontrolcontainselectronicStart/Stop and Inhibit circuits that can be usedtostartand
stop the control. However, these circuits are never to be used as safety disconnects since they
are not fail-safe. Use only the AC line for this purpose.
Theinputcircuitsofthiscontrol(potentiometer,start/stop,Inhibit)arenotisolatedfromAC
line. Be sure to follow all instructions carefully. Fire and/or electrocution can result due
to improper use of this product.
Thisproduct complies with all CE directives pertinent at the time of manufacture.
Contact factory for detailed installation instructions and Declaration of
Conformity. Installation of a CE approved RFI filter (KBRF-200A, KB P/N 9945C or
equivalent) is required. Additional shielded motor cable and/or AC line cables may be
required along with a signal isolator (SI-4X, KB P/N 8801 or equivalent).
I. GENERAL INFORMATION.
The KBRG is a full-wave regenerative control, capable of operating a DC motor (Permanent
Magnet or Shunt) in a bidirectional mode. It provides 4-quadrant operation which allows
forward and reverse torque in both speed directions. The drive offers excellent controllability,
whichcloselyapproximatesthe performanceofservo-type drives. Ratingsandspecifications
are presented in tables 1 and 2. Be sure the drive is used within these ratings and
specifications.
(Note: Regenerative drives normally produce more motor heating than standard
unidirectional SCR speed controls, especially under low speed operation. This should
be taken into consideration when specifying motor rating.)
WARNING! Besure to followall instructions carefully. Fireor electrocution
can result due to improper use of this product. Read Safety Warning.
TABLE 1 – ELECTRICAL RATINGS
Model Part No. Input
Voltage
(VAC)
Max. AC
Current
(RMS)
Output
Voltage
(VDC)
Max. DC
Output
Current (ADC)
Max.
Horsepower
HP, (KW)
KBRG-240D 8802 115 16 0 – ±90 11 1, (.75)
230 16 0 – ±180 11 2, (1.5)
KBRG-225D 8800 115 24 0 – ±90 16 1, (1)
230 24 0 – ±180 16 3, (2)