MTR-11 PTC Temperature Controllers Operation Manual
100517
Parameter Information
Parameter Information Note
KCE Power On
PFR Input Signal Failed Check PTC1000 sensor
37 **Crash Please send the controller to the
retail dealer
RFA PV Anomaly Temperature is too high or too low
RL1 & HY1 Setting
Function Setting Description
SV Press SET
Key Range: uSP ~ nSP
(-50~150℃)
HY1 Press HYS
Key 1-10
Parameter
Description
Parameter Value Description Range
PAR Input Parameter setting
uSP -50 Input low limit -50~-150℃
nSP 150 Input high limit -50~-150℃
rt1 / rt2 00 Hysteresis of RL1(/RL2 ) setting 0~10 min.
PF1 / PF2 ON RL1(/RL2) ON-OFF setting,When
RL1> L1+HY1,RL1(/RL2) will motion ON/OFF
ADJ 00 PV Compensation -20~20℃
HY1 / HY2 10 Temperature deviation of RL1(/RL2 ) -25~25℃
Parameter and Setting
Key Description
Terminal Assignment
Specifications
Model MTR-11
Dimension 78W*35H*77D mm
Faceplate 70W*28H mm
LED Size 0.52”
Range -50~150℃
Input PTC 1000;2 wires
Operating
Humi. 50~85%RH
Operating
Temp. -10°~+50℃
Accuracy ± 1℃
Power ACV 110、220、85~265,
DC12/24V
Weight 220g
Parts 2M PTC100 Sensor ×1,Operation
Manual ×1
typ tun tHs t2L t2S
uSP
PAR
Setting Input low
Range:-50℃~150℃
nSP Setting Input high
Range:-50℃~150℃
set
set
rt1 Hysteresis of RLt1
Range:0~10 min.
set
PF1 Output1 ON/OFF
setting
set
AdJ PV Compensation
Range:-20℃~20℃
set
HY1 Deviation of RL1
Range::-25℃~25℃
set
HY2 Deviation of RL2
Range::-25℃~25℃
set
rt2 Hysteresis of RL2
Range:0~10 min.
set
PF2 Output2 ON/OFF
setting
set
ndt
set
set
Display when RL2 is provided
set
set
set
set
set
set
Press
at the same
time ,and
open the
power again
set
1 2 3 4 5 6 7 8 9 10 11 12
NO COM NC NO COM NC
2 RELAY(AC85-265V& DC 12/24V)
PWR
5A 3A
PTC1000
- +
+ -
RL1 RL2
1 2 3 4 5 6 7 8 9 10 11 12
RL1 PWR
+ -
COM NO NC OV ACV
/DCV
PTC1000
- +
2000-MTR-R1-02
MTR-142-1
1 2 3 4 5 6 7 8 9 10 11 12
RL1 PWR
+ -
COM NO NC COM NO NC OV ACV
/DCV
PTC1000
- +
2000-MTR-R2-02
RL2
1 2 3 4 5 6 7 8 9 10 11 12
NO COM NC
1 RELAY(AC85-265V & DC 12/24V)
PWR
5A
PTC1000
- +
+ -
RL1 MTR-142-1
5A 3A
5A
OV ACV
/DCV
OV ACV
/DCV
1 RELAY(AC110/220V & DC 12/24V) 2 RELAY(AC110/220V & DC 12/24V)
Original
Value 10
hys
Power On
set
Original
Value 25
3 Sec.
3 Sec. Original
Value 25
hys
Power On
set
Original
Value 25
3 Sec.
3 Sec.
Output:
1 Relay Output:
2 Relay
(Note:
L2 zero value only L1 zero value)