KCVENTS FM-125-06 User manual

NOTE:
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to
comply with these instructions could result in personal injury and/or property damage. Retain these
instructions for future reference.
Techn ical parameter
MAINTENANCE
To reduce the risk of fire, electrical shock or injury to persons, observe the following:
A. Maintenance is to be performed only by qualified personnel who are familiar with local codes and
regulations and are experienced with this type of product.
B.
Before servicing or cleaning the product switch power off at service panel and lock service panel to prevent power
from being switched “ON” accidentally.
Routine maintenance is required to keep this product operating at its peak performance and efficiency. Over
time, the housing, air intake grille, air intake filter, blower wheels and motor(s) will accumulate a build up of
dust, debris and other residue. It is imperative to keep these components clean. Failure to do so will not only
lower operational efficiency and performance, but also reduce the useful life of the product. The time between
cleanings depends on the application, location and daily hours of use. On average, under normal use
conditions, the product should require a thorough cleaning once every six (6) months.
To clean the product, perform the following:
1.
Verify the product has been disconnected from the power source.
2. Use a damp cloth and either a warm mild soapy water solution or bio-degradable degreaser, to wipe
down the exterior components of the housing.
3. To access the interior of the product, remove the air intake grille(s) and/or air intake filter(s). This i s
accomplished by removing the screws on the face of the air intake grille(s)/filter(s).
4. Thoroughly clean the air intake grille(s)/filter(s).
5. Thoroughly wipe down the motor, blower wheels and blower wheel housings. Be careful not to spray
the motor with a water hose.
6. The motor(s) require no additional lubrication. They are permanently lubricated and feature double
sealed ball bearings.
7. To re-install the product, reverse the procedures above.
8. Reconnect the power source to the product.
9. If you have any questions regarding the maintenance of the product, contact the manufacturer.
Air Curtain
FM-125-06
FM-125-09
FM-125-10
FM-125-12
FM-125-15
FM-125-18
FM-125-20
220
220
220
220
220
220
220
50/60
50/60
50/60
50/60
50/60
50/60
50/60
9-11
9-11
9-11
9-11
9-11
9-11
9-11
850
1410
1500
1930
2630
3180
3510
50
50
51
51
52
52
53
120
125
145
160
190
240
280
600*145*185
900*145*185
1000*145*185
1200*145*185
1500*145*185
1800*145*185
2000*145*185
Model
Item Rated
Voltage
(V)
Rated
Frequency
(Hz)
Air
velocity
(m/s)
Air
vulume
(m³/h)
Noise
(dB)
Input
Power
(W)
Unit Size
(mm)

OVERVIEW
Our company air curtain are designed to cover door openings, providing both temperature
control/environmental separation and flying insect control when the building’s doors are opened.
Installation heights are up to 3 meters high. The units are typically wall mounted horizontally above the
door opening. They can also be suspended from the ceiling.
INSTALLATION
Typical Mounting – Wall or Ceiling Mounted
Horizontally Above the Door Opening
1. Gently remove all packaging materials, hardware
and all other accessories from interior of unit prior
to operating. Severe unit damage will occur if these
items are not removed prior to operation.
2. Lay unit on its top with directional vanes
pointing up and remove the tightening screws from
the wall mounting plate, just behind the discharge
nozzle, and remove the mounting plate from the
unit. (PIC 1) Measure the mounting plate and
center it over the opening. The air curtain shall be
equal to or greater than the width of the opening.
3. Install the mounting plate above the opening. (PIC2)
4. Align the tabs on the rear of the unit with the slots provided on the wall mounting plate. The bottom
flange on the unit must also drop in the bottom channel of the wall mounting plate. Replace the tightening
screws to secure the unit in place.(PIC3)
5. Mount the product such that the discharge is 3CM above the opening and all obstacles.
6. If applicable, optional Adjustable Mounting Brackets, Side Extension Plates and Extended W all
Mounted Brackets are also available for installations over a Vertical Lift or Drum Roll-up type door.
7. If applicable, for tandem installation or products mounted side by side, allow no more than 15cm
between the two products.
8. All wires must be connected internal of the unit and some knockouts are provided. However, it may be
necessary to create your own knockout, as required.
9. The unit and any optional accessories must be wired with the proper voltage to the junction box per the
wiring diagram.(PIC4)
WARNING
To reduce the risk of fire, electric shock or injury to persons, observe the
following.
A. Always disconnect, lock and tag power source before installing or servicing
product.
B. Installation work or electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-rated
construction.
C. The combustion airflow needed for safe operation of fuel burning
equipment in the area may be affected by the product’s operation. Follow the
heating equipment manufacturer’s guideline and safety standards.
D. When cutting or drilling into a wall or ceiling, be careful not to damage
electrical wiring and other hidden utilities.
This manual suits for next models
6
Table of contents
Popular Heater manuals by other brands

Oceanic
Oceanic OCEACV100IFW2 instructions

Calix
Calix M7T 734 Assembly instructions

EOS
EOS VITAE Assembly Instruction and instructions for use

Suntec Wellness
Suntec Wellness Klimatronic AIR BOOSTER 2000 OSC instruction manual

Aqua-Hot
Aqua-Hot 200 Series installation manual

TPI
TPI 6300/T Series user manual