During installing and using the device, please follow local electrical safety regulations strictly.
Ÿ
Please use power supply in the safe voltage range of our product. Make sure if the power supply is correct
Ÿ
before running the device.
Please transport, use and store the device within defined humidity and temperature ranges.
Ÿ
Do not expose it in damp, dusty, extremely hot or cold places or places with intense electromagnetic
Ÿ
radiation or with unstable lighting.
Keep the camera away from water or any liquid
Ÿ to avoid damage to internal components.
While shipping the camera, pack it in the factory packing or use materials with equivalent quality.
Ÿ
When shipping, storing and installing the device, try to prevent it from damages caused by pressure,
Ÿ
violentvibration and soaking.
1. Power Supply
2.Working Environment
I. Preface
II. Safety Instruction
Thank you for purchasing our product. If there is any question, please do not hesitate to contact us.
These instructions are intended to ensure that the user can use the product correctly to avoid danger or
property loss. Please read this Guide carefully before using the product, and keep it properly for future
reference. If the product cannot work normally or is damaged because the user does not follow the safety
instructions, we shall not assume any responsibility. Thanks for your cooperation.
Working Environment
DC12V±10%, Power: 25W max
-40℃~+60℃
10%~95% (non-condensing)
86kPa~106kPa
-60m~3000m
Voltage
Temp.
Humidity
Altitude
Pressure

2
3. Special Statement
The product appearance is subject to the actual device and picture in this Guide is for reference only..
Ÿ
Every effort has been made to ensure the accuracy and validity of this Guide. Any update of this Guide
Ÿ
caused by version upgrade is subject to change without notice.
This Guide is made for multiple models but it will not illustrate one by one. Please refer to it according to the
Ÿ
actual products you are using.
This device can be used after being activated through IPCSearch with a valid email address for claiming the
Ÿ
password.
To ensure the safety of device on internet, it is strongly recommended that you set a strong password which
Ÿ
is composed of at least 2 kinds of the following, digits, case-sensitive letters or specific symbols, and whose
length ranges from 8 to 16 bits. Please modify the password periodically and once every 3 months is
recommended. If the device is used in highly risky environment, suggest modifying the password monthly or
weekly. Please keep your user name and password safe.
Accessing this device to the internet is at user's own risk, including but not limited to the possible network
Ÿ
attack, hacker attack, virus infection and etc. This company will not assume any responsibility for problems
of product abnormality and information disclosure caused thereof. We shall provide technical support
relating to the products in time.
For the latest documents, please download at our website www.kedacom.com.
Ÿ

3
III. Appearance and Interface
9
10
6
5
4
2
3
12
8
13
7
11
1
No.
Name
No.
Name
1
Lens
8
4xScrew Holes (fix wall)
2
White Fill Light
9
2xStaple Bolt
3
IR Light
10
Flange Plate
4
Screen
11
Locking Screw
5
Card Reader
12
Wire Hole
6
Junction Box
13
2x Screw Holes (fix junction box)
7
Shield
14
Tamper Button
[Note]
When install with the 86 box, the “Flange Plate” should be pinched off with a plier so that the buttcock line can
be threaded out; when install without the 86 box, the “Wire Hole” should be pinched off with a plier so that the
buttcock line can be threaded out.
Components:
14

Dimensions:
Unit: mm
94.245.6
54.2
39
215
50
149.5
50
60
4×Φ5.9
46
78
4

Buttcock Line:
1
2
3
5
No.
Interface Name
Function Description
1
Network
Connect to network access devices like a switch
2
Power supply
Connect to power supply of DC12V
3
User cable group
Including alarm in /out, RS-485 serial port and etc.
Table 1 Wire Interface
Cut off terminal wires
Tag 1
Tag 3
Tag 2

6
Table 2 User Cable Group Interface
Interface
No.
Color
Port Name
Function Description
User
Cable
Group
1
Yellow
NC
Normally closed door lock port
2
Pink
COM
Door lock port
3
White
NO
Normally open door lock port
4
White Brown
SENS
Door magnetic port
5
Light Green
GND
Grounding
6
Gray
Rs485+
RS-485 serial port, to control external devices
such as third-party device
7
Purple
RS485-
8
Green
GND
Grounding
9
Blue
ALARM OUT
Alarm output port
10
White Orange
ALARM OUT
Alarm output port
11
Brown
BUT
Door-open button Port
12
White Red
GND
Grounding
13
White Purple
ALARM IN-1
Alarm input port
14
White Black
GND
Grounding
15
White Blue
ALARM IN-2
Alarm input port
16
White Yellow
GND
Grounding

IV. Wire Connection
7
Cut off the user cable group and connect to RS-485, door lock, door-open button, door magnetic, alarm device,
card reader and etc.
ALARM IN-1 White Purple
White Black
White Blue
White Yellow
Blue
White Orange
ALARM IN-2
ALARM OUT
ALARM OUT COM
GND 13
14
15
16
9
10
GND
NC 1
4
5
11
12
2
3
Yellow
Pink
White
White Brown
Brown
White Red
Light Green
NO
COM
SENS
GND
GND
BUT
RS485+ Gray
6
7
8
Purple
Green
RS485-
GND
Door Lock
Power Input DC12V-
DC12V+ DC12V+
DC12V+Power
Black
Red
NC
Door
Lock
NO
Door
Lock
(NC)
Power
(NO)
Door Magnetic
Door Open Button
RS485
Door
Magnetic
Alarm Input
Alarm Output
Power Switch
Power
Alarm Input Device
Alarm Input Device
Alarm Output Device
KSCA120

8
Connect to Door Lock
The device supports NO type and NC type locks, whose connection methods are different. Please refer to the
following:
NO Magnetic Lock
System with Access Controller
NC Magnetic Lock
NO
+
+
-
-
COM
NC
NC Magnetic Lock
DC Power Adapter
Access Control
Relay Output
NO
++
+
-
-
Access Controller
COM
NC
NC Magnetic Lock
Access Control
Relay Output
NO
+
+
-
-
COM
NC
NO Magnetic Lock
DC Power Adapter
Access Control
Relay Output

1.5m
Recommended installation height:
1.5m from the ground to the lens
9
V. Installation
[Note] Please make sure the environment meets requirements before installation. For detailed instructions for
the installation environment, please refer to the Appendix.
If install the device indoor, it should be at least 2m away from the light source and at least 3m from the window
and door to avoid direct sunlight.
Please make sure the illumination of the light source in the environment is over 100 Lux.
The recommended installation height is 1.5m from the ground to the device lens, or you can adjust the height
according to human height.

10
Install Micro SD Card and Nano SIM Card
Micro SD Card Slot
SIM Card Slot
[Note] Some models do not support Nano SIM card. Please subject to actual models.
The device supports Nano SIM card. Please cut the card by request.
Loosen the screws to take down the card lid and then insert the Micro SD card and Nano SIM card, as shown
below. After finish installation, tighten the screws and cover the card lid. The Micro SD card supports maximum
256G. After the Micro SD card is inserted, it cannot be hot-swapped and you must format the card for first time
use.
[Note] After installing the Micro SD card and Nano SIM card, the card lid must be covered to avoid damages to
the device caused by water leakage.

11
1. Install 86 box (the recommended installation height of 86 box is 1.3m from the ground);
2. Align the 2 screw holes at the bottom of the shield back to the 2 screw holes on 86 box, and use a marking pen
to make marks on the wall at the 2 holes on the top, then drill holes and insert the expansion screw tubes;
3. Pinch off the flange plate on the shield with pliers, and then fix the shield onto the 86 box with two cross
recessed countersunk head screws M4*50 (factory accessories);
4. Fix the shield onto the wall with two cross countersunk head stainless steel tapping screws ST3.9*25C
(factory accessories);
5. Align the holes on the device back to the staple bolts on the shield, thread the staple bolts through the holes
and pull down the device so that the device is hung on the shield. Thread the buttcock line of the device
through the shield and place into the 86 box;
6. Tighten the fixing screws at the bottom and finish installation;
7. Peel off the protective film on the screen.
Install with 86 Box (Recommended)
Wall
86 Box
Shield
Device
3
4
5
6
1
For convenience and elegance sake, we recommend the installation method with 86 box.
Expansion Screw Tube
2
Pinch off Flange Plate
7
1.3m

12
Install without 86 Box
If there isn’t 86 box on the wall, the installation needs help of a junction box (factory accessories).
1. Drill holes on the wall according to the four holes on the shield and insert the expansion screw tubes;
2. Pinch off the dam-board at the wire hole on the shield with pliers, and then fix the shield onto the wall with four
cross countersunk head stainless steel tapping screws ST3.9*25C (factory accessories);
3. Align the holes on the device back to the staple bolts on the shield, thread the staple bolts through the holes
and pull down the device so that the device is hung on the shield. Thread the buttcock line through the wire
hole;
4. Tighten the fixing screws at the bottom;
1
2
3
4Pinch off Dam-board
6

13
5. Twist the screws on the junction box halfway and cover the junction box as the picture indicates, then cross the
screw-driver through the holes at the bottom of the junction box and tighten the screws to fix the junction box
and the device. The port of the buttcock line is placed inside the junction box and the buttcock line is threaded
out from the wire hole at the bottom of the junction box.
Port of Buttcock Line Hidden Inside the Junction Box
6. After finish installation, peel off the protective film on the screen.

14
Install on No Punch Wall
1. Pinch off the dam-board at the wire hole on the shield with pliers;
2. Align the holes on the device back to the staple bolts on the shield, thread the staple bolts through the holes
and pull down the device so that the device is hung on the shield;
3. Tighten the screws at the bottom to fix the device and the shield.
[Note] When install the device on no punch wall, double-sided adhesive tape will be necessary. Before sticking
the double-sided adhesive tape, please clean the back of the shield and the mounting wall surface so as
to ensure the firmness of the double-sided adhesive tape.

15
4. Clean the back of the shield and take out the double-sided adhesive tape from the attached accessories. Peel
off one side of the tape and align the two round holes on it to the two screw holes on the top of the shield and
press hard to stick the device onto the tape.
5. Confirm the installation position and clean the mount surface. Peel off another side of the tape and paste the
whole device onto the wall and press it hard.
Double-sided adhesive tape for the shield

16
6. Twist the screws on the junction box halfway and cover the junction box as the picture indicates, then cross the
screw-driver through the holes at the bottom of the junction box and tighten the screws to fix the junction box
and the device. The port of the buttcock line is placed inside the junction box and the buttcock line is threaded
out from the wire hole at the bottom of the junction box.
Port of Buttcock Line Hidden Inside the Junction Box

17
7. After finish installation, peel off the protective film on the screen.

18
VI. Startup
1. Activate Device.
You need to activate the device during first time of use. When the device is powered on, it will come to the
activation interface, as shown below.
There are three methods to activate the device: activate through device, through IPCSearch and through Web
client.
Activate Through Device
Click “Local Activation” on the interface as shown above and configure password, confirm password and email
(for claiming password), and click “Activate” to finish.
Activate
Activation
weak strong
Password length should be 8-16 bits, combination of 2 or more kinds of
numbers, case-sensitive letters and specific symbols.
Please confirm password
Please enter email
Please and access to a network
activate the device through
IPCSearch before using.
Local Activation
Other manuals for KSCA120 Series
1
Table of contents
Other Kedacom IP Access Controllers manuals